2,145 research outputs found

    Philosophical and epistemological debate in Italy within an ethical perspective of Earth sciences

    Get PDF
    During the recent "Geoitalia" national congress, the Italian scientific community tackled questions concerning the philosophy and sociology of Earth Sciences. The topics discussed and reported in this article were: the overall identity of E.S.; the validation procedures of data, theories and models; the power of attraction exerted by the philosophy of physics - exact science par excellence - with respect to E.S

    Comparison and calibration of a real-time virtual stenting algorithm using Finite Element Analysis and Genetic Algorithms

    Get PDF
    In this paper, we perform a comparative analysis between two computational methods for virtual stent deployment: a novel fast virtual stenting method, which is based on a spring–mass model, is compared with detailed finite element analysis in a sequence of in silico experiments. Given the results of the initial comparison, we present a way to optimise the fast method by calibrating a set of parameters with the help of a genetic algorithm, which utilises the outcomes of the finite element analysis as a learning reference. As a result of the calibration phase, we were able to substantially reduce the force measure discrepancy between the two methods and validate the fast stenting method by assessing the differences in the final device configurations

    A device to characterize optical fibres

    Get PDF
    ATLAS is a general purpose experiment approved for the LHC collider at CERN. An important component of the detector is the central hadronic calorimeter; for its construction more than 600,000 Wave Length Shifting (WLS) fibres (corresponding to a total length of 1,120 Km) have been used. We have built and put into operation a dedicated instrument for the measurement of light yield and attenuation length over groups of 20 fibres at a time. The overall accuracy achieved in the measurement of light yield (attenuation length) is 1.5% (3%). We also report the results obtained using this method in the quality control of a large sample of fibres.Comment: 17 pages 20 figeres submitted to NIM journa

    Computational modelling for congenital heart disease: how far are we from clinical translation?

    Get PDF
    Computational models of congenital heart disease (CHD) have become increasingly sophisticated over the last 20 years. They can provide an insight into complex flow phenomena, allow for testing devices into patient-specific anatomies (pre-CHD or post-CHD repair) and generate predictive data. This has been applied to different CHD scenarios, including patients with single ventricle, tetralogy of Fallot, aortic coarctation and transposition of the great arteries. Patient-specific simulations have been shown to be informative for preprocedural planning in complex cases, allowing for virtual stent deployment. Novel techniques such as statistical shape modelling can further aid in the morphological assessment of CHD, risk stratification of patients and possible identification of new 'shape biomarkers'. Cardiovascular statistical shape models can provide valuable insights into phenomena such as ventricular growth in tetralogy of Fallot, or morphological aortic arch differences in repaired coarctation. In a constant move towards more realistic simulations, models can also account for multiscale phenomena (eg, thrombus formation) and importantly include measures of uncertainty (ie, CIs around simulation results). While their potential to aid understanding of CHD, surgical/procedural decision-making and personalisation of treatments is undeniable, important elements are still lacking prior to clinical translation of computational models in the field of CHD, that is, large validation studies, cost-effectiveness evaluation and establishing possible improvements in patient outcomes

    Carbon based substrates for interfacing neurons: Comparing pristine with functionalized carbon nanotubes effects on cultured neuronal networks

    Get PDF
    Pristine (as prepared) carbon nanotube (CNT) based substrates have been widely used to grow and interface neurons in culture. Nerve cells normally differentiate on CNTs and the synaptic networks, newly formed at the interface with this material, usually show an improved robustness in signal transfer. However manipulation of pristine CNTs is often prevented by their low dispersibility and tendency to aggregate in most solvents. This issue can be at least partially solved by adding solubilizing groups to the surface of CNT, which also helps improving their biocompatibility. It becomes therefore of crucial importance to determine whether chemically manipulated CNTs may maintain their performance in improving nerve signaling. Here we study and compare the impact in vitro on neuronal signaling of two classes of chemically modified multiwalled CNTs in reference to pristine CNTs, which are known to be a substrate able to boost neuronal growth and communication. We found that the extent of functionalization and the nature of the functional groups on MWNT sidewalls affect the conductivity and the biological effects of the final derivatives. This information is important for the future design of biointegrated devices

    In vivo estimation of target registration errors during augmented reality laparoscopic surgery

    Get PDF
    PURPOSE: Successful use of augmented reality for laparoscopic surgery requires that the surgeon has a thorough understanding of the likely accuracy of any overlay. Whilst the accuracy of such systems can be estimated in the laboratory, it is difficult to extend such methods to the in vivo clinical setting. Herein we describe a novel method that enables the surgeon to estimate in vivo errors during use. We show that the method enables quantitative evaluation of in vivo data gathered with the SmartLiver image guidance system. METHODS: The SmartLiver system utilises an intuitive display to enable the surgeon to compare the positions of landmarks visible in both a projected model and in the live video stream. From this the surgeon can estimate the system accuracy when using the system to locate subsurface targets not visible in the live video. Visible landmarks may be either point or line features. We test the validity of the algorithm using an anatomically representative liver phantom, applying simulated perturbations to achieve clinically realistic overlay errors. We then apply the algorithm to in vivo data. RESULTS: The phantom results show that using projected errors of surface features provides a reliable predictor of subsurface target registration error for a representative human liver shape. Applying the algorithm to in vivo data gathered with the SmartLiver image-guided surgery system shows that the system is capable of accuracies around 12 mm; however, achieving this reliably remains a significant challenge. CONCLUSION: We present an in vivo quantitative evaluation of the SmartLiver image-guided surgery system, together with a validation of the evaluation algorithm. This is the first quantitative in vivo analysis of an augmented reality system for laparoscopic surgery

    Population-specific material properties of the implantation site for transcatheter aortic valve replacement finite element simulations

    Get PDF
    Patient-specific computational models are an established tool to support device development and test under clinically relevant boundary conditions. Potentially, such models could be used to aid the clinical decision-making process for percutaneous valve selection; however, their adoption in clinical practice is still limited to individual cases. To be fully informative, they should include patient-specific data on both anatomy and mechanics of the implantation site. In this work, fourteen patient-specific computational models for transcatheter aortic valve replacement (TAVR) with balloon-expandable Sapien XT devices were retrospectively developed to tune the material parameters of the implantation site mechanical model for the average TAVR population. Pre-procedural computed tomography (CT) images were post-processed to create the 3D patient-specific anatomy of the implantation site. Balloon valvuloplasty and device deployment were simulated with finite element (FE) analysis. Valve leaflets and aortic root were modelled as linear elastic materials, while calcification as elastoplastic. Material properties were initially selected from literature; then, a statistical analysis was designed to investigate the effect of each implantation site material parameter on the implanted stent diameter and thus identify the combination of material parameters for TAVR patients. These numerical models were validated against clinical data. The comparison between stent diameters measured from post-procedural fluoroscopy images and final computational results showed a mean difference of 2.5 ± 3.9%. Moreover, the numerical model detected the presence of paravalvular leakage (PVL) in 79% of cases, as assessed by post-TAVR echocardiographic examination. The final aim was to increase accuracy and reliability of such computational tools for prospective clinical applications

    Reconstructing 3D x-ray CT images of polymer gel dosimeters using the zero-scan method

    Get PDF
    In this study x-ray CT has been used to produce a 3D image of an irradiated PAGAT gel sample, with noise-reduction achieved using the ‘zero-scan’ method. The gel was repeatedly CT scanned and a linear fit to the varying Hounsfield unit of each pixel in the 3D volume was evaluated across the repeated scans, allowing a zero-scan extrapolation of the image to be obtained. To minimise heating of the CT scanner’s x-ray tube, this study used a large slice thickness (1 cm), to provide image slices across the irradiated region of the gel, and a relatively small number of CT scans (63), to extrapolate the zero-scan image. The resulting set of transverse images shows reduced noise compared to images from the initial CT scan of the gel, without being degraded by the additional radiation dose delivered to the gel during the repeated scanning. The full, 3D image of the gel has a low spatial resolution in the longitudinal direction, due to the selected scan parameters. Nonetheless, important features of the dose distribution are apparent in the 3D x-ray CT scan of the gel. The results of this study demonstrate that the zero-scan extrapolation method can be applied to the reconstruction of multiple x-ray CT slices, to provide useful 2D and 3D images of irradiated dosimetry gels

    Dietary Nitrate: Effects on the health of weaning pigs and Antimicrobial activity on seven probiotic Bifidobacterium spp. strains

    Get PDF
    The potential role of nitrite as an antimicrobial substance in the stomach may be of some importance in the ecology of the gastrointestinal tract and in host physiology. It has been shown that nitrite, under the acidic conditions of the stomach, may kill gut pathogens like Salmonella enteritidis, Escherichia coli, Salmonella typhimurium, and Yersinia enterocolitica, whereas acid alone has only a bacteriostatic effect. An in vivo study was conducted in order to assess the effects of dietary nitrate on microbiota and on the health of the gut (particularly in the stomach and small intestine). 96 weaning pigs were fed a diet containing high nitrate levels (15 mg and 150 mg) and then challenged with Salmonella enterica serovar typhimurium. Differences in composition of the gut microbiota were assessed by analysing samples from the pigs: To date analysis of 48 pigs has been completed.. Preliminary results demonstrated no effect on the population densities of microbial groups either from the challenge or from nitrate intake. However, increasing the time from challenge decreased either the counts of LAB in the stomach and jejunum or of clostridia in the stomach. Bifidobacteria also decreased in the stomach contents as nitrate supplementation increased. Supplementing the feedstuff with high dietary nitrate intake and then challenging with Salmonella did not affect the gastric pH or the degree of ulceration in the pigs. The synergistic bactericidal effects of pH, nitrite and thiocyanate on seven probiotic Bifidobacterium spp. strains were also investigated in an in vitro study. The results of the in vitro study demonstrated that an inhibitory effect exists on the seven probiotic bifidobacteria investigated with an exposure longer than 2 hours and pH values < 5.0. Addition of thiocyanate also increased the susceptibility of the tested strains. In this in vitro study, the most resistant strains at all conditions were B. animalis subsp. lactis Ra 18 and P32 and B. choerinum Su 877, Su 837 and Su 891
    • …
    corecore