9 research outputs found

    Development and Beam-Shape Analysis of an Integrated Fiber-Optic Confocal Probe for High-Precision Central Thickness Measurement of Small-Radius Lenses

    No full text
    This work describes a new design of a fiber-optic confocal probe suitable for measuring the central thicknesses of small-radius optical lenses or similar objects. The proposed confocal probe utilizes an integrated camera that functions as a shape-encoded position-sensing device. The confocal signal for thickness measurement and beam-shape data for off-axis measurement can be simultaneously acquired using the proposed probe. Placing the probe’s focal point off-center relative to a sample’s vertex produces a non-circular image at the camera’s image plane that closely resembles an ellipse for small displacements. We were able to precisely position the confocal probe’s focal point relative to the vertex point of a ball lens with a radius of 2.5 mm, with a lateral resolution of 1.2 µm. The reflected beam shape based on partial blocking by an aperture was analyzed and verified experimentally. The proposed confocal probe offers a low-cost, high-precision technique, an alternative to a high-cost three-dimensional surface profiler, for tight quality control of small optical lenses during the manufacturing process

    Fabrication of protein microarrays for alpha fetoprotein detection by using a rapid photo-immobilization process

    Get PDF
    In this study, protein microarrays based on sandwich immunoassays are generated to quantify the amount of alpha fetoprotein (AFP) in blood serum. For chip generation a mixture of capture antibody and a photoactive copolymer consisting of N,N-dimethylacrylamide (DMAA), methacryloyloxy benzophenone (MaBP), and Na-4-styrenesulfonate (SSNa) was spotted onto unmodified polymethyl methacrylate (PMMA) substrates. Subsequently to printing of the microarray, the polymer and protein were photochemically cross-linked and the forming, biofunctionalized hydrogels simultaneously bound to the chip surface by short UV- irradiation. The obtained biochip was incubated with AFP antigen, followed by biotinylated AFP antibody and streptavidin-Cy5 and the fluorescence signal read-out. The developed microarray biochip covers the range of AFP in serum samples such as maternal serum in the range of 5 and 100 ng/ml. The chip production process is based on a fast and simple immobilization process, which can be applied to conventional plastic surfaces. Therefore, this protein microarray production process is a promising method to fabricate biochips for AFP screening processes. Keywords: Photo-immobilization, Protein microarray, Alpha fetoprotein, Hydrogel, 3D surface, Down syndrom

    Fabrication of protein microarrays for alpha fetoprotein detection by using a rapid photo-immobilization process

    Get PDF
    In this study, protein microarrays based on sandwich immunoassays are generated to quantify the amount of alpha fetoprotein (AFP) in blood serum. For chip generation a mixture of capture antibody and a photoactive copolymer consisting of N,N-dimethylacrylamide (DMAA), methacryloyloxy benzophenone (MaBP), and Na-4-styrenesulfonate (SSNa) was spotted onto unmodified polymethyl methacrylate (PMMA) substrates. Subsequently to printing of the microarray, the polymer and protein were photochemically cross-linked and the forming, biofunctionalized hydrogels simultaneously bound to the chip surface by short UV- irradiation. The obtained biochip was incubated with AFP antigen, followed by biotinylated AFP antibody and streptavidin-Cy5 and the fluorescence signal read-out. The developed microarray biochip covers the range of AFP in serum samples such as maternal serum in the range of 5 and 100 ng/ml. The chip production process is based on a fast and simple immobilization process, which can be applied to conventional plastic surfaces. Therefore, this protein microarray production process is a promising method to fabricate biochips for AFP screening processes. Keywords: Photo-immobilization, Protein microarray, Alpha fetoprotein, Hydrogel, 3D surface, Down syndrom

    Significant Sensitivity Improvement for Camera-Based Lateral Flow Immunoassay Readers

    No full text
    Recent developments in smartphone-based strip readers have further improved the performances of lateral flow test kits. Most smartphone cameras encode an unaltered and nonlinear power-law transfer function that maps the light intensity to a pixel value; this poses some limitations for camera-based strip readers. For faint-color test lines which are almost as white such as with nitrocellulose pads, the slope of the transfer function is low. Therefore, it is difficult to differentiate between the faint test lines and the white background. We show that by manually setting the camera exposure time—instead of using the automatic settings—to the high-slope region of the transfer function, the reader’s sensitivity can be improved. We found that the sensitivity and the limit of detection of the Acidovorax avenae subsp. citrulli (Aac) test kit were enhanced up to 3-fold and 5-fold, respectively, when using the readers at the optimal camera settings, compared to the automatic mode settings. This simple technique can be readily applied to any existing camera-based colorimetric strip reader to significantly improve its performance

    ABO Blood-Typing Using an Antibody Array Technique Based on Surface Plasmon Resonance Imaging

    Get PDF
    In this study, readily available antibodies that are used in standard agglutination tests were evaluated for their use in ABO blood typing by a surface plasmon resonance imaging (SPR imaging) technique. Five groups of antibodies, including mixed clones of anti-A, anti-B, and anti-AB, and single clones of anti-A and anti-B, were used to construct the five-line detection arrays using a multichannel flow cell in the SPR imager. The red blood cell (RBC) samples were applied to a multichannel flow cell that was orthogonal to the detection line arrays for blood group typing. We found that the blood samples were correctly grouped in less than 12 min by the SPR imaging technique, and the results were consistent with those of the standard agglutination technique for all 60 samples. We found that mixed clones of antibodies provided 33%–68% greater change in the SPR signal than the single-clone antibodies. Applying the SPR imaging technique using readily available antibodies may reduce the costs of the antibodies, shorten the measurement time, and increase the throughput
    corecore