7,684 research outputs found
The ephemeris, orbital decay, and masses of 10 eclipsing HMXBs
We take advantage of more than 10 years of monitoring of the eclipsing HMXB
systems LMC X-4, Cen X-3, 4U 1700-377, 4U 1538-522, SMC X-1, IGR J18027-2016,
Vela X-1, IGR J17252-3616, XTE J1855-026, and OAO 1657-415 with the ASM
on-board RXTE and ISGRI on-board INTEGRAL to update their ephemeris. These
results are used to refine previous measurements of the orbital period decay of
all sources (where available) and provide the first accurate values of the
apsidal advance in Vela X-1 and 4U 1538-522. Updated values for the masses of
the neutron stars hosted in the ten HMXBs are also provided, as well as the
long-term lightcurves folded on the sources best determined orbital parameters.
These lightcurves reveal complex eclipse ingresses and egresses, that are
understood mostly as being due to the presence of accretion wakes. The results
reported in this paper constitute a database to be used for population and
evolutionary studies of HMXBs, as well as theoretical modelling of long-term
accretion in wind-fed X-ray binaries.Comment: Accepted for publication on A&
Reducing the Number of Sputum Samples Examined and Thresholds for Positivity: An Opportunity to Optimise Smear Microscopy.
SETTING: Urban health clinic, Nairobi. OBJECTIVE: To evaluate the impact on tuberculosis (TB) case detection and laboratory workload of reducing the number of sputum smears examined and thresholds for diagnosing positive smears and positive cases. DESIGN: In this prospective study, three Ziehl-Neelsen stained sputum smears from consecutive pulmonary TB suspects were examined blind. The standard approach (A), > or = 2 positive smears out of 3, using a cut-off of 10 acid-fast bacilli (AFB)/100 high-power fields (HPF), was compared with approaches B, > or = 2 positive smears (> or = 4 AFB/100 HPF) out of 3, one of which is > or = 10 AFB/100 HPF; C, > or = 2 positive smears (> or = 4 AFB/100 HPF) out of 3; D, > or = 1 positive smear (> or = 10 AFB/100 HPF) out of 2; and E, > or = 1 positive smear (> or = 4 AFB/100 HPF) out of 2. The microscopy gold standard was detection of at least one positive smear (> or = 4 AFB/100 HPF) out of 3. RESULTS: Among 644 TB suspects, the alternative approaches detected from 114 (17.7%) (approach B) to 123 cases (19.1%) (approach E) compared to 105 cases (16.3%) for approach A (P < 0.005). Sensitivity ranged between 82.0% (105/128) for A and 96.1% (123/128) for E. The single positive smear approaches reduced the number of smears by 36% compared to approach A. CONCLUSION: Reducing the number of specimens and the positivity threshold to define a positive case increased the sensitivity of microscopy and reduced laboratory workload
Added value of bleach sedimentation microscopy for diagnosis of tuberculosis: a cost-effectiveness study.
SETTING: Bleach sedimentation is a method used to increase the diagnostic yield of sputum microscopy for countries with a high prevalence of human immunodeficiency virus (HIV) infection and limited resources. OBJECTIVES: To compare the relative cost-effectiveness of different microscopy approaches in diagnosing tuberculosis (TB) in Kenya. METHODS: An analytical decision tree model including cost and effectiveness measures of 10 combinations of direct (D) and overnight bleach (B) sedimentation microscopy was constructed. Data were drawn from the evaluation of the bleach sedimentation method on two specimens (first on the spot [1] and second morning [2]) from 644 TB suspects in a peripheral health clinic. Incremental cost per smear-positive detected case was measured. Costs included human resources and materials using a micro-costing evaluation. RESULTS: All bleach-based microscopy approaches detected significantly more cases (between 23.3% for B1 and 25.9% for B1+B2) than the conventional D1+D2 approach (21.0%). Cost per tested case ranged between respectively euro 2.7 and euro 4.5 for B1 and B1+D2+B2. B1 and B1+B2 were the most cost-effective approaches. D1+B2 and D1+B1 were good alternatives to avoid using approaches exclusively based on bleach sedimentation microscopy. CONCLUSIONS: Among several effective microscopy approaches used, including sodium hypochlorite sedimentation, only some resulted in a limited increase in the laboratory workload and would be most suitable for programmatic implementation
Quark propagator in a covariant gauge
Using mean--field improved gauge field configurations, we compare the results
obtained for the quark propagator from Wilson fermions and Overlap fermions on
a \3 lattice at a spacing of fm.Comment: 5 pages, 8 figures, talk given by F.D.R. Bonnet at LHP 2001 workshop,
Cairns, Australi
Pseudo-critical clusterization in nuclear multifragmentation
In this contribution we show that the biggest fragment charge distribution in
central collisions of Xe+Sn leading to multifragmentation is an admixture of
two asymptotic distributions observed for the lowest and highest bombarding
energies. The evolution of the relative weights of the two components with
bombarding energy is shown to be analogous to that observed as a function of
time for the largest cluster produced in irreversible aggregation for a finite
system. We infer that the size distribution of the largest fragment in nuclear
multifragmentation is also characteristic of the time scale of the process,
which is largely determined by the onset of radial expansion in this energy
range.Comment: 4 pages, 3 figures, Contribution to conference proceedings of the
25th International Nuclear Physics Conference (INPC 2013
Performance of LED-Based Fluorescence Microscopy to Diagnose Tuberculosis in a Peripheral Health Centre in Nairobi.
Sputum microscopy is the only tuberculosis (TB) diagnostic available at peripheral levels of care in resource limited countries. Its sensitivity is low, particularly in high HIV prevalence settings. Fluorescence microscopy (FM) can improve performance of microscopy and with the new light emitting diode (LED) technologies could be appropriate for peripheral settings. The study aimed to compare the performance of LED-FM versus Ziehl-Neelsen (ZN) microscopy and to assess feasibility of LED-FM at a low level of care in a high HIV prevalence country
Hadron Masses From Novel Fat-Link Fermion Actions
The hadron mass spectrum is calculated in lattice QCD using a novel fat-link
clover fermion action in which only the irrelevant operators in the fermion
action are constructed using smeared links. The simulations are performed on a
16^3 x 32 lattice with a lattice spacing of a=0.125 fm. We compare actions with
n=4 and 12 smearing sweeps with a smearing fraction of 0.7. The n=4 Fat-Link
Irrelevant Clover (FLIC) action provides scaling which is superior to
mean-field improvement, and offers advantages over nonperturbative 0(a)
improvement, including a reduced exceptional configuration problem.Comment: 12 pages, 4 figures, new simulation with mean-field improved clover,
further discussion of actio
- …