1,171 research outputs found
Enhanced charge detection of spin qubit readout via an intermediate state
We employ an intermediate excited charge state of a lateral quantum dot
device to increase the charge detection contrast during the qubit state readout
procedure, allowing us to increase the visibility of coherent qubit
oscillations. This approach amplifies the coherent oscillation magnitude but
has no effect on the detector noise resulting in an increase in the signal to
noise ratio. In this letter we apply this scheme to demonstrate a significant
enhancement of the fringe contrast of coherent Landau-Zener-Stuckleberg
oscillations between singlet S and triplet T+ two-spin states.Comment: 3 pages, 3 figure
Generation of high-purity higher-order Laguerre-Gauss beams at high laser power
We have investigated the generation of highly pure higher-order
Laguerre-Gauss (LG) beams at high laser power of order 100W, the same regime
that will be used by 2nd generation gravitational wave interferometers such as
Advanced LIGO. We report on the generation of a helical type LG33 mode with a
purity of order 97% at a power of 83W, the highest power ever reported in
literature for a higher-order LG mode.Comment: 5 pages, 6 figure
Novel technique for thermal lens measurement in commonly used optical components
The absorption of light in transmissive optics cause a thermally
induced effect known as thermal lensing. This effect provokes an often
undesired change of a laser beam transmitted by the optic. In this paper we
present a measurement method that allows us to determine thermal lensing
in commonly used optical components. The beam influenced by the thermal
lens is expanded into the eigenmodes of an optical cavity, and its modal
content is analyzed in the eigenbasis of the cavity. The measured quantity
depends neither on beam parameters nor on the position of the optical
component under investigation. This method allows, to our knowledge, for
the first time the direct measurement of the mode conversion coefficient je2j
of the thermal lens
Comparison of EMP and HERO programs
Because of the unique features of electromagnetic pulse (EMP) and Hazardous
Electromagnetic Effects on Ordnance (HERO), much research and money has gone into
protecting weapon systems and ordnance against it. The EMP and HERO phenomena
do have a variety of differences and require differences of hardening technique to protect
against it. However, they both involve radiation effects and can prematurely initiate
ordnance via the electroexplosive device (EED). Protection of weapon systems and
ordnance against electronic damage and upset plus EED initiation takes on more of an
art form rather than science once basic principles are applied. Nevertheless by relating
these two programs via the initiating temperature of the EED. they can be accurately
compared with each other. Because of this observation, the two programs can be
effectively combined to work jointly on ordnance hardening and protection including all
forms of radiation type hazards, present and future.http://archive.org/details/comparisonofemph00bogaLieutenant. United States NavyApproved for public release; distribution is unlimited
Stabilized high-power laser system for the gravitational wave detector advanced LIGO
An ultra-stable, high-power cw Nd:YAG laser system, developed for the ground-based gravitational wave detector Advanced LIGO (Laser Interferometer Gravitational-Wave Observatory), was comprehensively characterized. Laser power, frequency, beam pointing and beam quality were simultaneously stabilized using different active and passive schemes. The output beam, the performance of the stabilization, and the cross-coupling between different stabilization feedback control loops were characterized and found to fulfill most design requirements. The employed stabilization schemes and the achieved performance are of relevance to many high-precision optical experiments
Providing Feedback Following Leadership Walkrounds is Associated with Better Patient Safety Culture, Higher Employee Engagement and Lower Burnout
Background There is a poorly understood relationship between Leadership WalkRounds (WR) and domains such as safety culture, employee engagement, burnout and work-life balance. Methods This cross-sectional survey study evaluated associations between receiving feedback about actions taken as a result of WR and healthcare worker assessments of patient safety culture, employee engagement, burnout and work-life balance, across 829 work settings. Results 16 797 of 23 853 administered surveys were returned (70.4%). 5497 (32.7% of total) reported that they had participated in WR, and 4074 (24.3%) reported that they participated in WR with feedback. Work settings reporting more WR with feedback had substantially higher safety culture domain scores (first vs fourth quartile Cohen’s d range: 0.34–0.84; % increase range: 15–27) and significantly higher engagement scores for four of its six domains (first vs fourth quartile Cohen’s d range: 0.02–0.76; % increase range: 0.48–0.70). Conclusion This WR study of patient safety and organisational outcomes tested relationships with a comprehensive set of safety culture and engagement metrics in the largest sample of hospitals and respondents to date. Beyond measuring simply whether WRs occur, we examine WR with feedback, as WR being done well. We suggest that when WRs are conducted, acted on, and the results are fed back to those involved, the work setting is a better place to deliver and receive care as assessed across a broad range of metrics, including teamwork, safety, leadership, growth opportunities, participation in decision-making and the emotional exhaustion component of burnout. Whether WR with feedback is a manifestation of better norms, or a cause of these norms, is unknown, but the link is demonstrably potent
Transportable setup for amplifier phase fidelity measurements
One possible laser source for the Laser Interferometer Space Antenna (LISA) consists of an Ytterbium-doped fiber amplifier originally developed for inter-satellite communication, seeded by the laser used for the technology demonstrator mission LISA Pathfinder. LISA needs to transmit clock information between its three spacecraft to correct for phase noise between the clocks on the individual spacecraft. For this purpose phase modulation sidebands at GHz frequencies will be imprinted on the laser beams between spacecraft. Differential phase noise between the carrier and a sideband introduced within the optical chain must be very low. We report on a transportable setup to measure the phase fidelity of optical amplifiers.DFG/EXC/QUESTDLR/50OQ1301DLR/50OQ060
Respiratory dysfunction in unsedated dogs with golden retriever muscular dystrophy
Golden retriever muscular dystrophy (GRMD) is a well-established model of Duchenne muscular dystrophy. The value of this model would be greatly enhanced with practical tools to monitor progression of respiratory dysfunction during treatment trials. Arterial blood gas analysis, tidal breathing spirometry, and respiratory inductance plethysmography (RIP) were performed to determine if quantifiable abnormalities could be identified in unsedated, untrained, GRMD dogs. Results from 11 dogs with a mild phenotype of GRMD and 11 age-matched carriers were compared. Arterial blood gas analysis was successfully performed in all dogs, spirometry in 21 of 22 (95%) dogs, and RIP in 18 of 20 (90%) dogs. Partial pressure of carbon dioxide and bicarbonate concentration were higher in GRMD dogs. Tidal breathing peak expiratory flows were markedly higher in GRMD dogs. Abnormal abdominal motion was present in 7 of 10 (70%) GRMD dogs. Each technique provided objective, quantifiable measures that will be useful for monitoring respiratory function in GRMD dogs during clinical trials while avoiding the influence of sedation on results. Increased expiratory flows and the pattern of abdominal breathing are novel findings, not reported in people with Duchenne muscular dystrophy, and might be a consequence of hyperinflation
A Comparison of Noninvasive Techniques to Survey Carnivore Communities in Northeastern North America
GEO 600 and the GEO-HF upgrade program: successes and challenges
The German-British laser-interferometric gravitational wave detector GEO 600
is in its 14th year of operation since its first lock in 2001. After GEO 600
participated in science runs with other first-generation detectors, a program
known as GEO-HF began in 2009. The goal was to improve the detector sensitivity
at high frequencies, around 1 kHz and above, with technologically advanced yet
minimally invasive upgrades. Simultaneously, the detector would record science
quality data in between commissioning activities. As of early 2014, all of the
planned upgrades have been carried out and sensitivity improvements of up to a
factor of four at the high-frequency end of the observation band have been
achieved. Besides science data collection, an experimental program is ongoing
with the goal to further improve the sensitivity and evaluate future detector
technologies. We summarize the results of the GEO-HF program to date and
discuss its successes and challenges
- …