880 research outputs found

    Suspicion of Acute Appendicitis in the Third Trimester of Pregnancy: Pros and Cons of a Laparoscopic Procedure

    Get PDF
    This review suggests that diagnostic laparoscopy during the third trimester of pregnancy is a logical strategy to minimize maternal and fetal risk when acute appendicitis is suspected

    Elevated central venous pressure is associated with impairment of microcirculatory blood flow in sepsis: A hypothesis generating post hoc analysis

    Get PDF
    Background: Microcirculatory driving pressure is defined as the difference between post-arteriolar and venular pressure. In previous research, an absence of correlation between mean arterial blood pressure (MAP) and microcirculatory perfusion has been observed. However, the microcirculation may be considered as a low pressure compartment with capillary pressure closer to venous than to arterial pressure. From this perspective, it is conceivable that central venous pressure (CVP) plays a more important role in determination of capillary perfusion. We aimed to explore associations between CVP and microcirculatory perfusion.Methods: We performed a post-hoc analysis of a prospective study in septic patients who were resuscitated according a strict non-CVP guided treatment protocol. Simultaneous measurements of hemodynamics and sublingual Sidestream Dark Field imaging were obtained 0 and 30 minutes after fulfillment of resuscitation goals. Data were examined for differences in microcirculatory variables for CVP ≤ or > 12 mmHg and its evolution over time, as well as for predictors of a microvascular flow index (MFI) 12 mmHg) group as compared to patients in the 'low' CVP (≤12 mmHg) group (1.4 ± 0.9 vs. 1.9 ± 0.9, P = 0.006; and 88 ± 21% vs. 95 ± 8%, P = 0.006 respectively). Perfusion pressure (MAP-CVP) and cardiac output did not differ significantly between both CVP groups. From time point 0 to 30 minutes, a significant increase in MFI (from 1.6 ± 0.6 to 1.8 ± 0.9, P = 0.027) but not in PPV, was observed, while CVP and perfusion pressure significantly decreased in the same period. In a multivariate model CVP > 12 mmHg was the only significant predictor for a capillary MFI < 2.6 (Odds ratio 2.5 (95% confidence interval 1.1-5.8), P = 0.026).Conclusion: We observed a significant association between a higher CVP and impairment of microcirculatory blood flow. Further research is needed to elaborate on our hypothesis generating findings that an elevated CVP may act as an outflow obstruction of organ perfusion

    The contemporary pulmonary artery catheter. Part 2:measurements, limitations, and clinical applications

    Get PDF
    Nowadays, the classical pulmonary artery catheter (PAC) has an almost 50-year-old history of its clinical use for hemodynamic monitoring. In recent years, the PAC evolved from a device that enabled intermittent cardiac output measurements in combination with static pressures to a monitoring tool that provides continuous data on cardiac output, oxygen supply and-demand balance, as well as right ventricular performance. In this review, which consists of two parts, we will introduce the difference between intermittent pulmonary artery thermodilution using bolus injections, and the contemporary PAC enabling continuous measurements by using a thermal filament which heats up the blood. In this second part, we will discuss in detail the measurements of the contemporary PAC, including continuous cardiac output measurement, right ventricular ejection fraction, end-diastolic volume index, and mixed venous oxygen saturation. Limitations of all of these measurements are highlighted as well. We conclude that thorough understanding of measurements obtained from the PAC is the first step in successful application of the PAC in daily clinical practice

    The contemporary pulmonary artery catheter. Part 1:placement and waveform analysis

    Get PDF
    Nowadays, the classical pulmonary artery catheter (PAC) has an almost 50-year-old history of its clinical use for hemodynamic monitoring. In recent years, the PAC evolved from a device that enabled intermittent cardiac output measurements in combination with static pressures to a monitoring tool that provides continuous data on cardiac output, oxygen supply and-demand balance, as well as right ventricular (RV) performance. In this review, which consists of two parts, we will introduce the difference between intermittent pulmonary artery thermodilution using cold bolus injections, and the contemporary PAC enabling continuous measurements by using a thermal filament which at random heats up the blood. In this first part, the insertion techniques, interpretation of waveforms of the PAC, the interaction of waveforms with the respiratory cycle and airway pressure as well as pitfalls in waveform analysis are discussed. The second part will cover the measurements of the contemporary PAC including measurement of continuous cardiac output, RV ejection fraction, end-diastolic volume index, and mixed venous oxygen saturation. Limitations of all of these measurements will be highlighted there as well. We conclude that thorough understanding of measurements obtained from the PAC are the first step in successful application of the PAC in daily clinical practice

    Public health information needs in districts

    Get PDF

    Ultrafiltration rate is an important determinant of microcirculatory alterations during chronic renal replacement therapy

    Get PDF
    Background: Hemodialysis (HD) with ultrafiltration (UF) in chronic renal replacement therapy is associated with hemodynamic instability, morbidity and mortality. Sublingual Sidestream Dark Field (SDF) imaging during HD revealed reductions in microcirculatory blood flow (MFI). This study aims to determine underlying mechanisms. Methods: The study was performed in the Medical Centre Leeuwarden and the Lithuanian University of Health Sciences. Patients underwent 4-h HD session with linear UF. Nine patients were subject to combinations of HD and UF: 4 h of HD followed by 1 h isolated UF and 4 h HD with blood-volume-monitoring based UF. Primary endpoint: difference in MFI before and after intervention. During all sessions monitoring included blood pressure, heartrate and SDF-imaging. Trial registration number: NCT01396980. Results: Baseline characteristics were not different between the two centres as within the HD/UF modalities. MFI was not different before and after HD with UF. Total UF did not differ between modalities. Median MFI decreased significantly during isolated UF [2.8 (2.5-2.9) to 2.5 (2.2-2.8), p = 0.03]. Baseline MFI of each UF session was correlated with MFI after the intervention (r s = 0.52, p = 0.006). Conclusion: During HD with UF or isolated HD we observed no changes in MFI. This indicates that non-flow mediated mechanisms are of unimportance. During isolated UF we observed a reduction in MFI in conjunction with a negative intravascular fluid balance. The correlation between MFI before and after intervention suggests that volume status at baseline is a factor in microvascular alterations. In conclusion we observed a significant decrease of sublingual MFI, related to UF rate during chronic renal replacement therapy
    • …
    corecore