4 research outputs found

    Interventional VSD-Closure with the Nit-Occlud(®) Lê VSD-Coil in 110 Patients: early and midterm results of the EUREVECO-Registry

    Full text link
    In August 2010, the Nit-Occlud(®) Lê (EUREVECO) became available for transcatheter coil occlusion of ventricular septal defects (VSDs). Retrospective European Registry for VSD Closure using the Nit-Occlud(®) Lê-VSD-Coil; analysis of the feasibility, results, safety and follow-up of VSD-closure over a 3-year period in 18 European centers. In 102 of 111 patients (female 66), successful VSD closure was performed (mean age 8.2 years, mean weight 28.82 kg), 81 perimembranous VSDs (48 with aneurysm), 30 muscular VSDs, mean procedure time was 121.1 min, and mean fluoroscopy time was 26.3 min. Short- and midterm term follow-up was possible in 100/102 patients, there was 1 embolization and 1 explantation after 24 months. Immediate complete closure occurred in 49 of 101 patients (48.5%), trivial residual shunt was present in 51 (50.0%), closure rate was 95% after 6 months and 97% after 1 year. Out of the 102 patients, there were 2 severe complications (1.8%) (1 severe hemolysis, 1 embolization) and 8 moderate/transient (=7.2%) including 1 transient AV block. During a mean follow-up period of 31.3 months (range 24-48) and a total follow-up time of 224.75 patient years, no further problems occurred. VSD closure with the Nit-Occlud(®) Lê VSD coil is feasible and safe with a minimal risk of severe side effects. The long-term effects and safety require further clinical follow-up studies

    Interventional VSD-Closure with the Nit-Occlud(®) Lê VSD-Coil in 110 Patients: Early and Midterm Results of the EUREVECO-Registry

    No full text
    In August 2010, the Nit-Occlud(®) Lê (EUREVECO) became available for transcatheter coil occlusion of ventricular septal defects (VSDs). Retrospective European Registry for VSD Closure using the Nit-Occlud(®) Lê-VSD-Coil; analysis of the feasibility, results, safety and follow-up of VSD-closure over a 3-year period in 18 European centers. In 102 of 111 patients (female 66), successful VSD closure was performed (mean age 8.2 years, mean weight 28.82 kg), 81 perimembranous VSDs (48 with aneurysm), 30 muscular VSDs, mean procedure time was 121.1 min, and mean fluoroscopy time was 26.3 min. Short- and midterm term follow-up was possible in 100/102 patients, there was 1 embolization and 1 explantation after 24 months. Immediate complete closure occurred in 49 of 101 patients (48.5%), trivial residual shunt was present in 51 (50.0%), closure rate was 95% after 6 months and 97% after 1 year. Out of the 102 patients, there were 2 severe complications (1.8%) (1 severe hemolysis, 1 embolization) and 8 moderate/transient (=7.2%) including 1 transient AV block. During a mean follow-up period of 31.3 months (range 24-48) and a total follow-up time of 224.75 patient years, no further problems occurred. VSD closure with the Nit-Occlud(®) Lê VSD coil is feasible and safe with a minimal risk of severe side effects. The long-term effects and safety require further clinical follow-up studies.status: publishe

    Acute and midterm outcomes of the post-approval MELODY Registry: a multicentre registry of transcatheter pulmonary valve implantation

    No full text
    AIMS: The post-approval MELODY Registry aimed to obtain multicentre registry data after transcatheter pulmonary valve implantation (TPVI) with the Melody™ valve (Medtronic plc.) in a large-scale cohort of patients with congenital heart disease (CHD). METHODS AND RESULTS: Retrospective analysis of multicentre registry data after TPVI with the Melody™ valve. Eight hundred and forty-five patients (mean age: 21.0 ± 11.1 years) underwent TPVI in 42 centres between December 2006 and September 2013 and were followed-up for a median of 5.9 years (range: 0-11.0 years). The composite endpoint of TPVI-related events during follow-up (i.e. death, reoperation, or reintervention >48 h after TPVI) showed an incidence rate of 4.2% per person per year [95% confidence interval (CI) 3.7-4.9]. Transcatheter pulmonary valve implantation infective endocarditis (I.E.) showed an incidence rate of 2.3% per person per year (95% CI 1.9-2.8) and resulted in significant morbidity and in nine deaths. In multivariable Cox proportional hazard models, the invasively measured residual right ventricle (RV)-to-pulmonary artery (PA) pressure gradient (per 5 mmHg) was associated with the risk of the composite endpoint (adjusted hazard ratio: 1.21, 95% CI 1.12-1.30; P 2 improved significantly from 36 [interquartile range (IQR) 24-47] to 12 (IQR 7-17) mmHg and 47 to 1%, respectively (P < 0.001 for each). CONCLUSION: The post-approval MELODY Registry confirms the efficacy of TPVI with the Melody™ valve in a large-scale cohort of CHD patients. The residual invasively measured RV-to-PA pressure gradient may serve as a target for further improvement in the composite endpoint and TPVI I.E. However, TPVI I.E. remains a significant concern causing significant morbidity and mortality.status: publishe
    corecore