12 research outputs found

    Thermostability of IFN-gamma and IP-10 release assays for latent infection with Mycobacterium tuberculosis: A TBnet study

    Get PDF
    INTRODUCTION:Interferon-γ (IFN-γ) inducible protein 10kD (IP-10) and IFN-γ release assays (IGRAs) are immunodiagnostic tests aiming to identify the presence of specific cellular immune responses, interpreted as markers for latent infection with Mycobacterium tuberculosis. Incubation at higher temperatures could affect IFN-γ and IP-10 responsiveness in order to improve the performance of IP-10 release assays and IGRAs. AIM:The aim of this study was to assess the robustness of whole blood based IP-10 release assay and IGRAs and the effect of hyper-thermic incubation (39 °C) on the diagnostic accuracy of IP-10 release assay and IGRAs. RESULTS:We included 65 patients with confirmed pulmonary tuberculosis and 160 healthy controls from 6 European centres collaborating in the TBnet. In patients, IP-10 responses increased 1.07 (IQR 0.90-1.36) fold and IFN-γ responses decreased 0.88 (IQR 0.57-1.02) fold, with 39 °C compared to 37 °C incubation temperature. At 37 °C IGRA sensitivity was 85% and IP-10 sensitivity was 82%, whereas specificity was 97% for both tests (p > 0.8). These minor changes observed as a result of hyper-thermic incubation were not sufficient to impact IGRA and IP-10 release assay test performance. CONCLUSION:The performance of IGRA and IP-10 release assays is robust despite variations in the incubation temperature between 37 °C and 39 °C

    Inter-Rater Agreement on Cincinnati Prehospital Stroke Scale (CPSS) and Prehospital Acute Stroke Severity Scale (PASS) Between EMS Providers, Neurology Residents and Neurology Consultants

    No full text
    Martin Gude,1 Hans Kirkegaard,1,2 Rolf Blauenfeldt,3 Anne Behrndtz,3 Jeppe Mainz,3 Ingunn Riddervold,4 Claus Z Simonsen,2,3 Niels Hjort,2,3 Søren P Johnsen,5 Grethe Andersen,2,3 Jan Brink Valentin5 1Department of Research and Development, Prehospital Emergency Medical Services, Central Denmark Region; and Aarhus University Hospital, Aarhus, Denmark; 2Department of Clinical Medicine, Aarhus University, Aarhus, Denmark; 3Danish Stroke Center, Department of Neurology, Aarhus University Hospital, Aarhus, Denmark; 4Norwegian Air Ambulance Foundation, Oslo, Norway; 5Danish Center for Clinical Health Services Research, Department of Clinical Medicine, Aalborg University, Aalborg, DenmarkCorrespondence: Martin Gude, Prehospital Emergency Medical Services, Central Denmark Region and Aarhus University Hospital, Aarhus, Denmark, Email [email protected]: To examine the agreement between emergency medical service (EMS) providers, neurology residents and neurology consultants, using the Cincinnati Prehospital Stroke Scale (CPSS) and the Prehospital Acute Stroke Severity Scale (PASS).Methods: Patients with stroke, transient ischemic attack (TIA) and stroke mimic were included upon primary stroke admission or during rehabilitation. Patients were included from June 2018 to September 2019. Video recordings were made of patients being assessed with CPSS and PASS. The recordings were later presented to the healthcare professionals. To determine relative and absolute interrater reliability in terms of inter-rater agreement (IRA), we used generalisability theory. Group-level agreement was determined against a gold standard and presented as an area under the curve (AUC). The gold standard was a consensus agreement between two neurology consultants.Results: A total of 120 patient recordings were assessed by 30 EMS providers, two neurology residents and two neurology consultants. Using the CPSS and the PASS, a total of 1,800 assessments were completed by EMS providers, 240 by neurology residents and 240 by neurology consultants. The overall relative and absolute IRA for all items combined from the CPSS and PASS score was 0.84 (95% CI 0.80; 0.87) and 0.81 (95% CI 0.77; 0.85), respectively. Using the CPSS, the agreement on a group-level resulted in AUCs of 0.83 (95% CI 0.78; 0.88) for the EMS providers and 0.86 (95% CI 0.82; 0.90) for the neurology residents when compared with the gold standard. Using the PASS, the AUC was 0.82 (95% CI 0.77; 0.87) for the EMS providers and 0.88 (95% CI 0.84; 0.93) for the neurology residents.Conclusion: The high relative and absolute inter-rater agreement underpins a high robustness/generalisability of the two scales. A high agreement exists across individual raters and different groups of healthcare professionals supporting widespread applicability of the stroke scales.Plain Language Summary: Early stroke identification is pivotal to enable faster treatment. To aid this identification, many symptom-based stroke scales have been constructed for both stroke screening and severity assessment. In the prehospital environment, several scales have been evaluated on performance, but only few studies have evaluated the agreement between the ambulance personnel (emergency medical service (EMS) providers) and stroke physicians when interpreting the assessed symptoms in the scales. It is of great importance to know how EMS providers interpret symptoms seen in connection with the use of the scales to focus the continuous training of the EMS providers but also to aid the decision on which scale to implement in ambulances. From previous studies, we know that complex stroke scales are used to a considerably lesser extent than more simple scales, which could be caused by difficulties interpreting specific symptoms. In this study, a variety of methods was applied to determine the inter-rater agreement for two simple stroke scales using dichotomously evaluated symptoms. High inter-rater agreement between EMS providers and Stroke Neurologists exists both between individual raters and between raters grouped according to their profession and seniority. Previous studies have also found high inter-rater agreement for simple stroke scales but lesser agreement for more advanced scales. In conclusion, simple stroke scales seem to produce the highest agreement.Keywords: observer variation, prehospital emergency care, emergency medical service provider, neurologists, strok

    Introducing the ESAT-6 free IGRA, a companion diagnostic for TB vaccines based on ESAT-6.

    No full text
    There is a need for an improved vaccine for tuberculosis. ESAT-6 is a cardinal vaccine antigen with unique properties and is included in several vaccine candidates in development. ESAT-6 is also the core antigen in the IFN-γ release assays (IGRA) used to diagnose latent infection, rendering IGRA tests unspecific after vaccination. This challenge has prompted the development of a companion diagnostic for ESAT-6 based vaccines, an ESAT-6 free IGRA. We screened a panel of seven potential new diagnostic antigens not recognized in BCG vaccinated individuals. Three highly recognized antigens EspC, EspF and Rv2348c were identified and combined with CFP10 in an ESAT-6 free antigen cocktail. The cocktail was prepared in a field-friendly format, lyophilized with heparin in ready-to-use vacutainer tubes. The diagnostic performance of the ESAT-6 free IGRA was determined in a cross-validation study. Compared IGRA, the ESAT-6 free IGRA induced a comparable magnitude of IFN-γ release, and the diagnostic performance was on par with Quantiferon (sensitivity 84% vs 79%; specificity 99% vs 97%). The comparable performance of the ESAT-6 free IGRA to IGRA suggests potential as companion diagnostic for ESAT-6 containing vaccines and as adjunct test for latent infection

    Introducing the ESAT-6 free IGRA, a companion diagnostic for TB vaccines based on ESAT-6.

    No full text
    There is a need for an improved vaccine for tuberculosis. ESAT-6 is a cardinal vaccine antigen with unique properties and is included in several vaccine candidates in development. ESAT-6 is also the core antigen in the IFN-γ release assays (IGRA) used to diagnose latent infection, rendering IGRA tests unspecific after vaccination. This challenge has prompted the development of a companion diagnostic for ESAT-6 based vaccines, an ESAT-6 free IGRA. We screened a panel of seven potential new diagnostic antigens not recognized in BCG vaccinated individuals. Three highly recognized antigens EspC, EspF and Rv2348c were identified and combined with CFP10 in an ESAT-6 free antigen cocktail. The cocktail was prepared in a field-friendly format, lyophilized with heparin in ready-to-use vacutainer tubes. The diagnostic performance of the ESAT-6 free IGRA was determined in a cross-validation study. Compared IGRA, the ESAT-6 free IGRA induced a comparable magnitude of IFN-γ release, and the diagnostic performance was on par with Quantiferon (sensitivity 84% vs 79%; specificity 99% vs 97%). The comparable performance of the ESAT-6 free IGRA to IGRA suggests potential as companion diagnostic for ESAT-6 containing vaccines and as adjunct test for latent infection

    Diagnostic benefits of adding EspC, EspF and Rv2348-B to the QuantiFERON Gold In-tube antigen combination

    Get PDF
    Interferon (IFN)-γ release assays (IGRAs) are used to diagnose latent tuberculosis (TB) infection (LTBI). To improve the accuracy of these tests, different approaches, such as alternative cytokine detection and using different antigens, are considered. Following this purpose, this study aims to evaluate the addition of EspC, EspF and Rv2348-B to those present in the QuantiFERON-TB Gold In-Tube (QFN-G-IT). We included 115 subjects: 74 active TB patients, 17 LTBI individuals and 24 healthy controls. Whole blood samples were collected in QFN-G-IT and in-house tubes containing different combinations of EspC, EspF and Rv2348-B, together with ESAT-6, CFP-10, and TB7.7. After overnight incubation at 37 ºC, plasma was harvested and IFN-γ quantified. IFN-γ levels in the QFN-G-IT and in-house tubes correlated very good (Spearman Rho(r) > 0.86). In-house antigen combinations distinguished healthy individuals from those with active TB and LTBI (specificities and sensitivities higher than 87.5% and 96.3%, respectively [AUC > 0.938]). Adding EspC, EspF and Rv2348-B, increased the sensitivity of the test, being the addition of EspC and Rv2348-B the combination that yielded a higher sensitivity with no specificity loss. Addition of these antigens could improve diagnosis in patients with impaired or immature immune response who are at high risk of developing T
    corecore