2,137 research outputs found

    A high-reflectivity high-Q micromechanical Bragg-mirror

    Get PDF
    We report on the fabrication and characterization of a micromechanical oscillator consisting only of a free-standing dielectric Bragg mirror with high optical reflectivity and high mechanical quality. The fabrication technique is a hybrid approach involving laser ablation and dry etching. The mirror has a reflectivity of 99.6%, a mass of 400ng, and a mechanical quality factor Q of approximately 10^4. Using this micromirror in a Fabry Perot cavity, a finesse of 500 has been achieved. This is an important step towards designing tunable high-Q high-finesse cavities on chip.Comment: 3 pages, 2 figure

    Force-Velocity and Power Characteristics of Rat Soleus Muscle Fibers after Hindlimb Suspension

    Get PDF
    The effects of 1, 2, and 3 wk of Hindlimb Suspension (HS) on force-velocity and power characteristics of single rat soleus fibers were determined. After 1, 2, or 3 wk of HS, small fiber bundles were isolated, placed in skinning solution, and stored at -20 C until studied. Single fibers were isolated and placed between a motor arm and force transducer, functional properties were studied, and fiber protein content was subsequently analyzed by sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE). Additional fibers were isolated from soleus of control and after 1 and 3 wk of HS, and fiber type distribution and myosin light chain stoichiometry were determined from SDS-PAGE analysis. After 1 wk of HS, percent type I fibers declined from 82 to 74%, whereas hybrid fibers increased from 10 to 18%. Percent fast type 11 fibers increased from 8% in control and 1 wk of HS to 26% by 3 wk of HS. Most fibers showed an increased unloaded maximal shortening velocity (V(sub 0)), but myosin heavy chain remained entirely slow type I. The mechanism for increased V(sub 0) is unknown. There was a progressive decrease in fiber diameter (14, 30, and 38%) and peak force (38, 56, and 63%) after 1, 2, and 3 wk of HS, respectively. One week of HS resulted in a shift of the force-velocity curve, and between 2 and 3 wk of HS the curve shifted further such that V(sub 0) was higher than control at all relative loads less than 45% peak isometric force. Peak absolute power output of soleus fibers progressively decreased through 2 wk of HS but showed no further change at 3 wk. The results suggest that between 2 and 3 wk the HS-induced alterations in the force-velocity relationship act to maintain the power output of single soleus fibers despite a continued reduction in fiber force

    Self-cooling of a micro-mirror by radiation pressure

    Get PDF
    We demonstrate passive feedback cooling of a mechanical resonator based on radiation pressure forces and assisted by photothermal forces in a high-finesse optical cavity. The resonator is a free-standing high-reflectance micro-mirror (of mass m=400ng and mechanical quality factor Q=10^4) that is used as back-mirror in a detuned Fabry-Perot cavity of optical finesse F=500. We observe an increased damping in the dynamics of the mechanical oscillator by a factor of 30 and a corresponding cooling of the oscillator modes below 10 K starting from room temperature. This effect is an important ingredient for recently proposed schemes to prepare quantum entanglement of macroscopic mechanical oscillators.Comment: 11 pages, 9 figures, minor correction

    Nephrotoxicity, high frequency ototoxicity, efficacy and serum kinetics of once versus thrice daily dosing of netilmicin in patients with serious infections

    Get PDF
    The effect of dosing regimen on nephrotoxicity, high frequency ototoxicity, efficacy and serum kinetics was studied in a prospective, randomised clinical study. Therapy was started with total daily doses of 6 mg/kg given once (od) or thrice (tid) daily to 56 and 57 patients, respectively. Subsequent doses were adjusted according to serum levels. No major differences in toxicity or efficacy were noticed between od and tid regimens: clinical failures occurred in two and two patients, four and five patients suffered from a decrease of ≥20 dB at least unilaterally at one frequency between 8 and 18 kHz, six and seven patients had a >25 μmol/L or >25% increase in serum creatinine, respectively. Serum creatinine or creatinine clearance did not change significantly during either therapy. Major differences between the two study groups were limited to pharmacokinetic parameters. Od dosing resulted in higher peak (mean of 21.6 vs 7.2 mg/L) and lower trough levels (0.5 vs 1.4mg/L). Half-lives of netilmicin determined between 1 and 8 h increased significantly during therapy with tid (from a mean of 2.75 to a mean of 3.33 h, P<0.01) but not significantly with od (rise from 2.8 to 3.03 h). Much longer half-lives were determined between 8 and 24 h in the od group (mean of 5.7 h, P<0.01). In conclusion, only minimal differences in toxicity and efficacy were observed. Their clinical relevance appears to be minima

    Do roots mind the gap?

    Get PDF
    corecore