343 research outputs found

    Efficient Ionization Investigation for Flow Control and Energy Extraction

    Get PDF
    Nonequilibrium ionization of air by nonthermal means is explored for hypersonic vehicle applications. The method selected for evaluation generates a weakly ionized plasma using pulsed nanosecond, high-voltage discharges sustained by a lower dc voltage. These discharges promise to provide a means of energizing and sustaining electrons in the air while maintaining a nearly constant ion/neutral molecule temperature. This paper explores the use of short approx.5 nsec, high-voltage approx.12 to 22 kV, repetitive (40 to 100 kHz) discharges in generating a weakly ionized gas sustained by a 1 kV dc voltage in dry air at pressures from 10 to 80 torr. Demonstrated lifetimes of the sustainer discharge current approx.10 to 25 msec are over three orders of magnitude longer than the 5 nsec pulse that generates the electrons. This life is adequate for many high speed flows, enabling the possibility of exploiting weakly ionized plasma phenomena in flow-fields such as those in hypersonic inlets, combustors, and nozzles. Results to date are obtained in a volume of plasma between electrodes in a bell jar. The buildup and decay of the visible emission from the pulser excited air is photographed on an ICCD camera with nanosecond resolution and the time constants for visible emission decay are observed to be between 10 to 15 nsec decreasing as pressure increases. The application of the sustainer voltage does not change the visible emission decay time constant. Energy consumption as indicated by power output from the power supplies is 194 to 669 W depending on pulse repetition rate

    Dental Phobia and Its Impact on the Quality of Life of a Ghanaian Adult Population

    Get PDF
    Aim: Dental phobia is a significant cause of avoidance of dental treatment, which could result in poor oral health. This study sought to determine the prevalence of dental phobia among a Ghanaian adult population and how this affects their quality of life. Materials and Methods: The study was a cross-sectional survey conducted among 329 patients attending the University of Ghana Dental School Clinic. Dental phobia was assessed with the Kleinknecht\u27s Dental Fear Survey (DFS),and Quality of Life measured with the Oral Health Impact Profile (OHIP). Data were analyzed using Stata 14 software and MS Excel. Descriptive statistics and measures of association between DFS and OHIP were done.Results: About 46% of the study population had some level of dental phobia, with 8% having a high level of fear. More males (54.2%) were found to have experienced dental phobia than females (45.8%). Common causes of dental phobia were injection (54.7%), x-ray (24.9%), the dental clinic environment (13.4%), and the sound and feel of the handpiece (0.9%).Conclusion: Dental phobia was common among the dental clinic attendants. While further research is required in the subject area, clinicians and stakeholders should not under-estimate its prevalence and potential effects. &nbsp

    Method and System for Weakening Shock Wave Strength at Leading Edge Surfaces of Vehicle in Supersonic Atmospheric Flight

    Get PDF
    A method and system are provided to weaken shock wave strength at leading edge surfaces of a vehicle in atmospheric flight. One or more flight-related attribute sensed along a vehicle's outer mold line are used to control the injection of a non-heated, non-plasma-producing gas into a local external flowfield of the vehicle from at least one leading-edge surface location along the vehicle's outer mold line. Pressure and/or mass flow rate of the gas so-injected is adjusted in order to cause a Rankine-Hugoniot Jump Condition along the vehicle's outer mold line to be violated

    Elite Suppressors Harbor Low Levels of Integrated HIV DNA and High Levels of 2-LTR Circular HIV DNA Compared to HIV+ Patients On and Off HAART

    Get PDF
    Elite suppressors (ES) are a rare population of HIV-infected individuals that are capable of naturally controlling the infection without the use of highly active anti-retroviral therapy (HAART). Patients on HAART often achieve viral control to similar (undetectable) levels. Accurate and sensitive methods to measure viral burden are needed to elucidate important differences between these two patient populations in order to better understand their mechanisms of control. Viral burden quantification in ES patients has been limited to measurements of total DNA in PBMC, and estimates of Infectious Units per Million cells (IUPM). There appears to be no significant difference in the level of total HIV DNA between cells from ES patients and patients on HAART. However, recovering infectious virus from ES patient samples is much more difficult, suggesting their reservoir size should be much smaller than that in patients on HAART. Here we find that there is a significant difference in the level of integrated HIV DNA in ES patients compared to patients on HAART, providing an explanation for the previous results. When comparing the level of total to integrated HIV DNA in these samples we find ES patients have large excesses of unintegrated HIV DNA. To determine the composition of unintegrated HIV DNA in these samples, we measured circular 2-LTR HIV DNA forms and found ES patients frequently have high levels of 2-LTR circles in PBMC. We further show that these high levels of 2-LTR circles are not the result of inefficient integration in ES cells, since HIV integrates with similar efficiency in ES and normal donor cells. Our findings suggest that measuring integration provides a better surrogate of viral burden than total HIV DNA in ES patients. Moreover, they add significantly to our understanding of the mechanisms that allow viral control and reservoir maintenance in this unique patient population

    A Tribute to the Mind, Methodology and Mentoring of Wayne Velicer

    Get PDF
    Wayne Velicer is remembered for a mind where mathematical concepts and calculations intrigued him, behavioral science beckoned him, and people fascinated him. Born in Green Bay, Wisconsin on March 4, 1944, he was raised on a farm, although early influences extended far beyond that beginning. His Mathematics BS and Psychology minor at Wisconsin State University in Oshkosh, and his PhD in Quantitative Psychology from Purdue led him to a fruitful and far-reaching career. He was honored several times as a high-impact author, was a renowned scholar in quantitative and health psychology, and had more than 300 scholarly publications and 54,000+ citations of his work, advancing the arenas of quantitative methodology and behavioral health. In his methodological work, Velicer sought out ways to measure, synthesize, categorize, and assess people and constructs across behaviors and time, largely through principal components analysis, time series, and cluster analysis. Further, he and several colleagues developed a method called Testing Theory-based Quantitative Predictions, successfully applied to predicting outcomes and effect sizes in smoking cessation, diet behavior, and sun protection, with the potential for wider applications. With $60,000,000 in external funding, Velicer also helped engage a large cadre of students and other colleagues to study methodological models for a myriad of health behaviors in a widely applied Transtheoretical Model of Change. Unwittingly, he has engendered indelible memories and gratitude to all who crossed his path. Although Wayne Velicer left this world on October 15, 2017 after battling an aggressive cancer, he is still very present among us

    Leachate Characterization and Assessment of Unsaturated Zone Pollution near Municipal Solid Waste Landfill Site at Oblogo, Accra-Ghana

    Get PDF
    Abstract: Leachate and unsaturated zone water samples were collected from landfill-site and its adjacent area at Oblogo, Accra-Ghana to study the possible impact of leachate percolation on unsaturated zone water quality. Concentration of various physico-chemical parameters including heavy metal (Cd, Cr, Cu, Fe, Mn, As, V, and Zn) were determined in unsaturated zone water and leachate samples. The moderately high concentrations of ClG, NO 3 G, SO 4 2 G, Fe, Zn, Cd, Cr, Cu, Fe, Mn, and BOD in unsaturated zone water, likely indicate that water quality in the unsaturated zone is being significantly affected by leachate percolation. This suggests that leachate percolation is having an impact the unsaturated zone water which indicates the originality of the groundwater in the area is threatened

    HLA-B*57 Elite Suppressor and Chronic Progressor HIV-1 Isolates Replicate Vigorously and Cause CD4+ T Cell Depletion in Humanized BLT Mice

    Get PDF
    Elite controllers or suppressors (ES) are HIV-1-infected patients who maintain undetectable viral loads without antiretroviral therapy. The mechanism of control remains unclear, but the HLA-B*57 allele is overrepresented in cohorts of these patients. However, many HLA-B*57 patients develop progressive disease, and some studies have suggested that infection with defective viruses may be the cause of the lack of high levels of virus replication and disease progression in ES. We therefore performed a comprehensive comparative in vivo and in vitro characterization of viruses isolated from well-defined ES. For this purpose, we first performed full-genome sequence analysis and in vitro fitness assays on replication-competent isolates from HLA-B*57 ES and HLA-B*57 chronic progressors (CPs). Under our experimental conditions, we found that isolates from ES and CPs can replicate in vitro. However, since inherently these assays involve the use of unnaturally in vitro-activated cells, we also investigated the replication competence and pathogenic potential of these HIV isolates in vivo using humanized BLT mice. The results from these analyses demonstrate that virus isolates from ES are fully replication competent in vivo and can induce peripheral and systemic CD4 T cell depletion. These results provide the first direct in vivo evidence that viral fitness does not likely determine clinical outcome in HLA-B*57 patients and that elite suppressors can control replication-competent, fully pathogenic viruses. A better understanding of the immunological bases of viral suppression in ES will serve to inform novel approaches to preventive and therapeutic HIV vaccine design

    Relationships of PBMC microRNA expression, plasma viral load, and CD4+ T-cell count in HIV-1-infected elite suppressors and viremic patients

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>HIV-1-infected elite controllers or suppressors (ES) maintain undetectable viral loads (< 50 copies/mL) without antiretroviral therapy. The mechanisms of suppression are incompletely understood. Modulation of HIV-1 replication by miRNAs has been reported, but the role of small RNAs in ES is unknown. Using samples from a well-characterized ES cohort, untreated viremic patients, and uninfected controls, we explored the PBMC miRNA profile and probed the relationships of miRNA expression, CD4+ T-cell counts, and viral load.</p> <p>Results</p> <p>miRNA profiles, obtained using multiple acquisition, data processing, and analysis methods, distinguished ES and uninfected controls from viremic HIV-1-infected patients. For several miRNAs, however, ES and viremic patients shared similar expression patterns. Differentially expressed miRNAs included those with reported roles in HIV-1 latency (miR-29 family members, miRs -125b and -150). Others, such as miR-31 and miR-31*, had no previously reported connection with HIV-1 infection but were found here to differ significantly with uncontrolled HIV-1 replication. Correlations of miRNA expression with CD4+ T-cell count and viral load were found, and we observed that ES with low CD4+ T-cell counts had miRNA profiles more closely related to viremic patients than controls. However, expression patterns indicate that miRNA variability cannot be explained solely by CD4+ T-cell variation.</p> <p>Conclusions</p> <p>The intimate involvement of miRNAs in disease processes is underscored by connections of miRNA expression with the HIV disease clinical parameters of CD4 count and plasma viral load. However, miRNA profile changes are not explained completely by these variables. Significant declines of miRs-125b and -150, among others, in both ES and viremic patients indicate the persistence of host miRNA responses or ongoing effects of infection despite viral suppression by ES. We found no negative correlations with viral load in viremic patients, not even those that have been reported to silence HIV-1 in vitro, suggesting that the effects of these miRNAs are exerted in a focused, cell-type-specific manner. Finally, the observation that some ES with low CD4 counts were consistently related to viremic patients suggests that miRNAs may serve as biomarkers for risk of disease progression even in the presence of viral suppression.</p

    Natural control of HIV infection in young women in South Africa: HPTN 068

    Get PDF
    Background: Some individuals control HIV replication without antiretroviral (ARV) therapy. Objective: To analyze viral suppression in young women in rural South Africa enrolled in a trial evaluating a behavioral intervention for HIV prevention. Methods: Plasma samples were obtained from women ages 13–24 (81 infected at enrollment, 164 seroconverters). ARV testing was performed using an assay that detects 20 ARV drugs. Women were classified as viremic controllers if they were virally suppressed for ≥12 months with no ARV drug use. Results: Samples from 216/245 (88.2%) women had no ARV drugs detected at their first HIV-positive visit. Thirty-four (15.7%) of the 216 women had a viral load <2,000 copies/mL. Fifteen of the 34 women were followed for ≥12 months; 12 were virally suppressed with no ARV drugs detected during follow-up. These women were classified as viremic controllers (overall: 12/216=5.6%). The median CD4 cell count at the first HIV-positive visit was higher among the 12 controllers than among the 204 women who were not using ARV drugs (759 vs. 549 cells/mm 3 , p=0.02). Some women had a viral load <40 copies/mL at a single study visit, but none were classified as elite controllers (viral load <40 copies/mL for ≥12 months with no ARV drug use). Conclusions: In this cohort, 5.6% of women who were not using ARV drugs had sustained viral suppression. This represents a minimum estimate of the frequency of viremic controllers in this cohort, since some women were not followed long enough to meet the criteria for classification
    corecore