13 research outputs found
Simultaneous determination of atorvastatin and ezetimibe from combined pharmaceutical products by micellar electrokinetic capillary chromatography
A rapid and sensitive micellar electrokinetic capillary chromatography method with UV photodiode-array detection was developed for the simultaneous determination of atorvastatin and ezetimibe in fixed dose drug combination. Experimental conditions such as buffer concentration and pH, surfactant concentration, system temperature, applied voltage, injection parameters were optimized in order to improve the efficiency of the separation. The best results were obtained when using fused silica capillary (48 cm length X 50 ”m ID) and 25 mM borate buffer electrolyte at pH 9.3 containing 25 mM SDS, + 30 kV applied voltage, 20 ÂșC system temperature. The separation was achieved in approximately 2 minutes, with a resolution of 7.02, the order of migration being atorvastatin followed by ezetimibe. The analytical performance of the method was verified with regard to linearity, precision, robustness and the limit of detection and quantification were calculated
Study of the effect of formulation variables on combination tablet characteristics containing enalapril maleate and indapamide as active substances using experimental design
To evaluate the influence of different variables on tablet formulations containing enalapril maleate and indapamide as active substances, two separate experimental designs were employed: one for evaluating powder properties and the other for tablet characteristics. Because of the low active pharmaceutical ingredient content, it was hypothesized that both powder and tablet properties could be determined only by the characteristics of excipients. In order to test this assumption, both experimental designs were done with placebo mixtures. The optimized formulation was then evaluated both with and without APIs. Results indicated that filler and lubricant percentage, along with compression force, were the most important variables during the formulation study. The optimized formulation showed similar characteristics in both cases for all responses, except for angle of repose and friability where only minor differences were observed. The combination of the applied approaches (using placebo composition and fractional experimental design) proved to be efficient, cost effective and time saving
HPLC method development for fampridine using Analytical Quality by Design approach
Offering a systematic and multivariate analysis of the analytical procedure, development and validation of HPLC methods using Quality by Design approach are in the limelight of current research trends. A new, experimental design-aided HPLC method for fampridine was developed and preliminarily validated according to current in-force international guidelines for linearity, accuracy, robustness and precision.
The method offers a high throughput sample analysis, with an elution time of 2.9 minutes, and signal detection without excipient interference performed at 262 nm. The method proved to be linear between 1â15 ”g mLâ1 (R2 = 0.9996). The mean recovery was found to be 98.7 ± 1.9 % in the tested range of 2.5â7.5 ”g mLâ1. Low RSD values (< 1 %) were obtained for both model, intra- and inter-day precision. The limit of detection and limit of quantification were 0.24 and 0.78 ”g mLâ1, resp. The method proved to be applicable for active substance assay in a pharmaceutical dosage form
Reversed phase HPLC for strontium ranelate: Method development and validation applying experimental design
A reverse-phase HPLC (RP-HPLC) method was developed for strontium ranelate using a full factorial, screening experimental design. The analytical procedure was validated according to international guidelines for linearity, selectivity, sensitivity, accuracy and precision. A separate experimental design was used to demonstrate the robustness of the method. Strontium ranelate was eluted at 4.4 minutes and showed no interference with the excipients used in the formulation, at 321 nm. The method is linear in the range of 20â320 ÎŒg mLâ1 (R2 = 0.99998). Recovery, tested in the range of 40â120 ÎŒg mLâ1, was found to be 96.1â102.1 %. Intra-day and intermediate precision RSDs ranged from 1.0â1.4 and 1.2â1.4 %, resp. The limit of detection and limit of quantitation were 0.06 and 0.20 ÎŒg mLâ1, resp. The proposed technique is fast, cost-effective, reliable and reproducible, and is proposed for the routine analysis of strontium ranelate
Simultaneous determination of atorvastatin and ezetimibe from combined pharmaceutical products by micellar electrokinetic capillary chromatography
Abstract A rapid and sensitive micellar electrokinetic capillary chromatography method with UV photodiode-array detection was developed for the simultaneous determination of atorvastatin and ezetimibe in fixed dose drug combination. Experimental conditions such as buffer concentration and pH, surfactant concentration, system temperature, applied voltage, injection parameters were optimized in order to improve the efficiency of the separation. The best results were obtained when using fused silica capillary (48 cm length X 50 ”m ID) and 25 mM borate buffer electrolyte at pH 9.3 containing 25 mM SDS, + 30 kV applied voltage, 20 ÂșC system temperature. The separation was achieved in approximately 2 minutes, with a resolution of 7.02, the order of migration being atorvastatin followed by ezetimibe. The analytical performance of the method was verified with regard to linearity, precision, robustness and the limit of detection and quantification were calculated
Study of the effect of formulation variables on the characteristics of combination tablets containing enalapril maleate and indapamide as active substances using experimental design
To evaluate the influence of different variables on tablet formulations containing enalapril maleate and indapamide as active substances, two separate experimental designs were employed: one for evaluating powder properties and the other for tablet characteristics. Because of the low active pharmaceutical ingredient content, it was hypothesized that both powder and tablet properties could be determined only by the characteristics of excipients. In order to test this assumption, both experimental designs were done with placebo mixtures. The optimized formulation was then evaluated both with and without APIs. Results indicated that filler and lubricant percentage, along with compression force, were the most important variables during the formulation study. The optimized formulation showed similar characteristics in both cases for all responses, except for angle of repose and friability where only minor differences were observed. The combination of the applied approaches (using placebo composition and fractional experimental design) proved to be efficient, cost effective and time saving
HPLC method development for fampridine using Analytical Quality by Design approach
Offering a systematic and multivariate analysis of the analytical procedure, development and validation of HPLC methods using Quality by Design approach are in the limelight of current research trends. A new, experimental design-aided HPLC method for fampridine was developed and preliminarily validated according to current in-force international guidelines for linearity, accuracy, robustness and precision