824 research outputs found
Persuasive Attack and Defense of Campus Free Speech: Implications for the First Amendment
This essay examines controversies and exchanges regarding free speech on college and university campuses in the United States. The authors offer an overview of the general discord about free speech and a review of the most current and relevant jurisprudence. Following this, theories of persuasive attack (Benoit and Dorries, 1996; Legge et al., 2012) and persuasive defense (Benoit, 1995) are used as a lens to characterize the topoi (opportunities for argument) from which attempts to limit or protect campus free speech proceed. Analysis points to future conflicts centered on viewpoint neutrality versus a compelling interest in protecting listeners from potentially harmful speech. While this hardly breaks new ground per se in terms of the viewpoint neutrality standard, the increasing concerns of advocacy groups and administrators in providing for more welcoming environments raise the specter of an augmented “compelling governmental interest” in equality and order which could weigh more heavily in censorship arguments. Finally, the most substantial contribution of this article is its delineation of a new method for identifying potential Constitutional arguments via established theories of communication
A review of potential contaminants in Australian livestock feeds and proposed guidance levels for feed
Contaminants of man-made and natural origin need to be managed in livestock feeds to protect the health of livestock and that of human consumers of livestock products. This requires access to information on the transfer from feed to food to inform risk profiles and assessments, and to guide management interventions such as regulation or Hazard Analysis Critical Control Point approaches. This paper reviews contaminants of known and potential concern in the production of livestock feeds in Australia and compares existing but differing state and national regulatory standards with international standards. The contaminants considered include man-made organic chemical contaminants (e.g. legacy pesticides), elemental contaminants (e.g. arsenic, cadmium, lead), phytotoxins (e.g. gossypol) and mycotoxins (e.g. aflatoxins). Reference is made to scientific literature and evaluations by regulators to propose maximum levels that can be used for guidance by those involved in managing contamination incidents or developing feed safety programs. © 2013 CSIRO
Recommended from our members
Fluorine in the Pahrump outcrop, Gale Crater: Implications for fluid circulation and alteration
Studies of a Lacustrine-Volcanic Mars Analog Field Site with Mars-2020-like Instruments
On the upcoming Mars‐2020 rover two remote sensing instruments, Mastcam‐Z and SuperCam, and two microscopic proximity science instruments, SHERLOC and PIXL, will collect compositional (mineralogy, chemistry, and organics) data essential for paleoenvironmental reconstruction. The synergies between and limitations of these instruments were evaluated via study of a Mars analog field site in the Mojave Desert, using instruments approximating the data that will be returned by Mars‐2020. A ground truth dataset was generated for comparison to validate the results. The site consists of a succession of clay‐rich mudstones of lacustrine origin, interbedded tuffs, a carbonate‐silica travertine deposit, and gypsiferous mudstone strata. The major geological units were mapped successfully using simulated Mars‐2020 data. Simulated Mastcam‐Z data identified unit boundaries and Fe‐bearing weathering products. Simulated SuperCam passive shortwave infrared and green Raman data were essential in identifying major mineralogical composition and changes in lacustrine facies at distance; this was possible even with spectrally downsampled passive IR data. LIBS and simulated PIXL data discriminated and mapped major element chemistry. Simulated PIXL revealed mm‐scale zones enriched in zirconium, of interest for age dating. SHERLOC‐like data mapped sulfate and carbonate at sub‐mm scale; silicates were identified with increased laser pulses/spot or by averaging of hundreds of spectra. Fluorescence scans detected and mapped varied classes of organics in all samples, characterized further with follow‐on spatially targeted deep‐UV Raman spectra. Development of dedicated organics spectral libraries is needed to aid interpretation. Given these observations, the important units in the outcrop would be sampled and cached for sample return
Vaccine candidates derived from a novel infectious cDNA clone of an American genotype dengue virus type 2
BACKGROUND: A dengue virus type 2 (DEN-2 Tonga/74) isolated from a 1974 epidemic was characterized by mild illness and belongs to the American genotype of DEN-2 viruses. To prepare a vaccine candidate, a previously described 30 nucleotide deletion (Δ30) in the 3' untranslated region of DEN-4 has been engineered into the DEN-2 isolate. METHODS: A full-length cDNA clone was generated from the DEN-2 virus and used to produce recombinant DEN-2 (rDEN-2) and rDEN2Δ30. Viruses were evaluated for replication in SCID mice transplanted with human hepatoma cells (SCID-HuH-7 mice), in mosquitoes, and in rhesus monkeys. Neutralizing antibody induction and protective efficacy were also assessed in rhesus monkeys. RESULTS: The rDEN2Δ30 virus was ten-fold reduced in replication in SCID-HuH-7 mice when compared to the parent virus. The rDEN-2 viruses were not infectious for Aedes mosquitoes, but both readily infected Toxorynchites mosquitoes. In rhesus monkeys, rDEN2Δ30 appeared to be slightly attenuated when compared to the parent virus as measured by duration and peak of viremia and neutralizing antibody induction. A derivative of rDEN2Δ30, designated rDEN2Δ30-4995, was generated by incorporation of a point mutation previously identified in the NS3 gene of DEN-4 and was found to be more attenuated than rDEN2Δ30 in SCID-HuH-7 mice. CONCLUSIONS: The rDEN2Δ30 and rDEN2Δ30-4995 viruses can be considered for evaluation in humans and for inclusion in a tetravalent dengue vaccine
Deep space 2: The Mars Microprobe Mission
The Mars Microprobe Mission will be the second of the New Millennium Program's technology development missions to planetary bodies. The mission consists of two penetrators that weigh 2.4 kg each and are being carried as a piggyback payload on the Mars Polar Lander cruise ring. The spacecraft arrive at Mars on December 3, 1999. The two identical penetrators will impact the surface at similar to 190 m/s and penetrate up to 0.6 m. They will land within 1 to 10 km of each other and similar to 50 km from the Polar Lander on the south polar layered terrain. The primary objective of the mission is to demonstrate technologies that will enable future science missions and, in particular, network science missions. A secondary goal is to acquire science data. A subsurface evolved water experiment and a thermal conductivity experiment will estimate the water content and thermal properties of the regolith. The atmospheric density, pressure, and temperature will be derived using descent deceleration data. Impact accelerometer data will be used to determine the depth of penetration, the hardness of the regolith, and the presence or absence of 1.0 cm scale layers
Blastomycosis in Man after Kinkajou Bite
We report transmission of Blastomyces dermatitidis fungal infection from a pet kinkajou to a man. When treating a patient with a recalcitrant infection and a history of an animal bite, early and complete animal necropsy and consideration of nonbacterial etiologies are needed
Studies of a Lacustrine-Volcanic Mars Analog Field Site with Mars-2020-like Instruments
On the upcoming Mars‐2020 rover two remote sensing instruments, Mastcam‐Z and SuperCam, and two microscopic proximity science instruments, SHERLOC and PIXL, will collect compositional (mineralogy, chemistry, and organics) data essential for paleoenvironmental reconstruction. The synergies between and limitations of these instruments were evaluated via study of a Mars analog field site in the Mojave Desert, using instruments approximating the data that will be returned by Mars‐2020. A ground truth dataset was generated for comparison to validate the results. The site consists of a succession of clay‐rich mudstones of lacustrine origin, interbedded tuffs, a carbonate‐silica travertine deposit, and gypsiferous mudstone strata. The major geological units were mapped successfully using simulated Mars‐2020 data. Simulated Mastcam‐Z data identified unit boundaries and Fe‐bearing weathering products. Simulated SuperCam passive shortwave infrared and green Raman data were essential in identifying major mineralogical composition and changes in lacustrine facies at distance; this was possible even with spectrally downsampled passive IR data. LIBS and simulated PIXL data discriminated and mapped major element chemistry. Simulated PIXL revealed mm‐scale zones enriched in zirconium, of interest for age dating. SHERLOC‐like data mapped sulfate and carbonate at sub‐mm scale; silicates were identified with increased laser pulses/spot or by averaging of hundreds of spectra. Fluorescence scans detected and mapped varied classes of organics in all samples, characterized further with follow‐on spatially targeted deep‐UV Raman spectra. Development of dedicated organics spectral libraries is needed to aid interpretation. Given these observations, the important units in the outcrop would be sampled and cached for sample return
Calibration of the MSL/ChemCam/LIBS Remote Sensing Composition Instrument
The ChemCam instrument suite on board the 2011 Mars Science Laboratory (MSL) Rover, Curiosity, will provide remote-sensing composition information for rock and soil samples within seven meters of the rover using a laser-induced breakdown spectroscopy (LIBS) system, and will provide context imaging with a resolution of 0.10 mradians using the remote micro-imager (RMI) camera. The high resolution is needed to image the small analysis footprint of the LIBS system, at 0.2-0.6 mm diameter. This fine scale analytical capability will enable remote probing of stratigraphic layers or other small features the size of "blueberries" or smaller. ChemCam is intended for rapid survey analyses within 7 m of the rover, with each measurement taking less than 6 minutes. Repeated laser pulses remove dust coatings and provide depth profiles through weathering layers, allowing detailed investigation of rock varnish features as well as analysis of the underlying pristine rock composition. The LIBS technique uses brief laser pulses greater than 10 MW/square mm to ablate and electrically excite material from the sample of interest. The plasma emits photons with wavelengths characteristic of the elements present in the material, permitting detection and quantification of nearly all elements, including the light elements H, Li, Be, B, C, N, O. ChemCam LIBS projects 14 mJ of 1067 nm photons on target and covers a spectral range of 240-850 nm with resolutions between 0.15 and 0.60 nm FWHM. The Nd:KGW laser is passively cooled and is tuned to provide maximum power output from -10 to 0 C, though it can operate at 20% degraded energy output at room temperature. Preliminary calibrations were carried out on the flight model (FM) in 2008. However, the detectors were replaced in 2009, and final calibrations occurred in April-June, 2010. This presentation describes the LIBS calibration and characterization procedures and results, and details plans for final analyses during rover system thermal testing, planned for early March
- …