653 research outputs found

    Controlling the cold collision shift in high precision atomic interferometry

    Get PDF
    We present here a new method based on a transfer of population by adiabatic passage that allows to prepare cold atomic samples with a well defined ratio of atomic density and atom number. This method is used to perform a measurement of the cold collision frequency shift in a laser cooled cesium clock at the percent level, which makes the evaluation of the cesium fountains accuracy at the 10−1610^{-16} level realistic. With an improved set-up, the adiabatic passage would allow measurements of atom number-dependent phase shifts at the 10−310^{-3} level in high precision experiments.Comment: 4 pages, 3 figures, 2 table

    SantĂ© mentale et exposition au risque de VIH chez les hommes ayant des rapports sexuels avec des hommes : rĂ©sultats de l’enquĂȘte suisse Gaysurvey 2014

    Get PDF
    Objectif: Evaluer la santĂ© mentale et l’homonĂ©gativitĂ© intĂ©riorisĂ©e des hommes ayant des rapports sexuels avec des hommes (HSH). MĂ©thode : L’enquĂȘte suisse Gaysurvey sur les comportements des HSH s’est dĂ©roulĂ©e en 2014 (N=834), par questionnaire Internet, anonyme, accessible sur diffĂ©rents sites frĂ©quentĂ©s par des HSH. Trois dimensions de la santĂ© mentale ont Ă©tĂ© Ă©valuĂ©es avec les indicateurs suivants: · dĂ©tresse psychologique (Ă©chelle K6) · niveau de bien-ĂȘtre psychologique (WHO-5) · homonĂ©gativitĂ© intĂ©riorisĂ©e (Smolenski et al. 2010) Les scores moyens ont Ă©tĂ© comparĂ©s entre 3 groupes d’ñge : <25 ans, 25-34 ans, ≄35 ans. L’exposition au risque VIH (rapport anal non protĂ©gĂ© avec un partenaire de statut sĂ©rologique diffĂ©rent ou inconnu) et le recours au test VIH au cours des 12 derniers mois ont Ă©galement Ă©tĂ© Ă©valuĂ©s en fonction de ces 3 dimensions

    Inventaire et description des modalitĂ©s de remise de matĂ©riel d’injection stĂ©rile en milieu carcĂ©ral en Suisse : Situation en 2016

    Get PDF
    Introduction : Les consommatrices et consommateurs de drogue par voie intraveineuse se retrouvent frĂ©quemment en prison oĂč ils tendent Ă  poursuivre leur consommation. Au vu des prĂ©valences Ă©levĂ©es d’infection par le VIH et le VHC, la rĂ©duction des risques est indiquĂ©e ; elle passe notamment par la remise de matĂ©riel d’injection stĂ©rile (RMIS). L’objectif est Ă©galement de respecter le principe « d’équivalence des soins » entre ce qui est proposĂ© en dehors de la prison et Ă  l’intĂ©rieur. La nouvelle loi sur les Ă©pidĂ©mies (LEp) et de son ordonnance (OEp) met l’accent sur cet objectif. Sa rĂ©cente entrĂ©e en vigueur va inciter les Ă©tablissements pĂ©nitentiaires Ă  questionner leurs pratiques en la matiĂšre. Dans ce contexte, l’Office fĂ©dĂ©ral de la SantĂ© publique (OFSP) a mandatĂ© l’Institut universitaire de mĂ©decine sociale et prĂ©ventive (IUMSP) de Lausanne pour faire un inventaire et une description des modalitĂ©s de RMIS en vigueur dans les prisons suisses en 2016. RepĂšres historiques : En 1992 la Suisse fait oeuvre de pionniĂšre. Un mĂ©decin pĂ©nitentiaire prend l’initiative de remettre du matĂ©riel d’injection stĂ©rile aux dĂ©tenus. Peu de temps aprĂšs, un projet pilote soutenu par l’OFSP voit le jour Ă  la prison pour femmes de Hindelbank oĂč six distributeurs de seringues sont mis Ă  disposition des dĂ©tenues. La mise en oeuvre de ce projet pilote se passe sans difficultĂ© et permet de conclure Ă  la faisabilitĂ© et Ă  l’utilitĂ© de mettre Ă  disposition des dĂ©tenu-e-s du matĂ©riel d’injection stĂ©rile. En 2001, sept Ă©tablissements en Suisse proposent du matĂ©riel d’injection stĂ©rile aux dĂ©tenu-e-s consommatrices et consommateurs de substances psychoactives par injection ; fin 2015, seuls 15 des 117 Ă©tablissements pĂ©nitentiaires que compte la Suisse ont un dispositif de RMIS : deux dans le canton de Soleure, trois dans le canton de Berne, un dans le canton de St-Gall, un dans les Grisons et huit Ă©tablissements dans le canton de GenĂšve. Objectifs et mĂ©thode de l’étude : Afin de rendre compte des dispositifs de RMIS en Suisse nous avons optĂ© pour une dĂ©marche comprĂ©hensive en recourant Ă  des entretiens semi-directifs (N=7) dans chaque Ă©tablissement concernĂ©. Ces entretiens se sont dĂ©roulĂ©s avec la personne responsable du service de santĂ© ou un-e professionnel-le impliquĂ©-e dans la RMIS. Les entretiens ont Ă©tĂ© enregistrĂ©s avec l’accord de nos interlocuteurs et ont fait l’objet d’une synthĂšse, puis d’une analyse thĂ©matique transversale. Une revue ciblĂ©e de la littĂ©rature scientifique a complĂ©tĂ© cette dĂ©marche

    Feshbach resonances in Cesium at Ultra-low Static Magnetic Fields

    Get PDF
    We have observed Feshbach resonances for 133Cs atoms in two different hyperfine states at ultra-low static magnetic fields by using an atomic fountain clock. The extreme sensitivity of our setup allows for high signal-to-noise-ratio observations at densities of only 2*10^7 cm^{-3}. We have reproduced these resonances using coupled-channels calculations which are in excellent agreement with our measurements. We justify that these are s-wave resonances involving weakly-bound states of the triplet molecular Hamiltonian, identify the resonant closed channels, and explain the observed multi-peak structure. We also describe a model which precisely accounts for the collisional processes in the fountain and which explains the asymmetric shape of the observed Feshbach resonances in the regime where the kinetic energy dominates over the coupling strength.Comment: 5 pages, 4 figures, 1 tabl

    A Search for Variations of Fundamental Constants using Atomic Fountain Clocks

    Get PDF
    Over five years we have compared the hyperfine frequencies of 133Cs and 87Rb atoms in their electronic ground state using several laser cooled 133Cs and 87Rb atomic fountains with an accuracy of ~10^{-15}. These measurements set a stringent upper bound to a possible fractional time variation of the ratio between the two frequencies : (d/dt)ln(nu_Rb/nu_Cs)=(0.2 +/- 7.0)*10^{-16} yr^{-1} (1 sigma uncertainty). The same limit applies to a possible variation of the quantity (mu_Rb/mu_Cs)*alpha^{-0.44}, which involves the ratio of nuclear magnetic moments and the fine structure constant.Comment: 4 pages, 3 figures, 1 table submitted to Phys. Rev. Let

    EnquĂȘte nationale sur la remise de matĂ©riel d’injection stĂ©rile par les pharmacies en 2016

    Get PDF
    Dans le cade du mandat de l’Office fĂ©dĂ©ral de la santĂ© publique concernant le systĂšme de suivi de la stratĂ©gie de lutte contre le VIH/Sida en Suisse, 2012-2016, l’Institut universitaire de mĂ©decine sociale et prĂ©ventive de Lausanne a menĂ© a trois reprises (1997, 2005 et 2016) une enquĂȘte nationale auprĂšs des pharmacies au sujet de la remise et de la vente de matĂ©riel d’injection stĂ©rile ainsi que de la dispensation de traitements de substitution. MĂ©thode : Cette enquĂȘte a Ă©tĂ© rĂ©alisĂ©e de janvier Ă  fĂ©vrier 2016 Ă  l’aide d’un questionnaire en allemand, français et italien adressĂ© Ă  l’ensemble des pharmacies de Suisse. La liste des pharmacies comprenait 1’347 membres de la SociĂ©tĂ© suisse des pharmaciens (SSPh, statistique au 08.01.2016) et 429 non membres. Les pharmacies devaient estimer le nombre moyen mensuel de seringues (seringues simples et boĂźtes Flash) vendues aux consommateurs de drogues pour la pĂ©riode d’octobre Ă  dĂ©cembre de l’annĂ©e prĂ©cĂ©dant l’enquĂȘte. Des questions portaient Ă©galement sur l’évolution de cette demande, le mode de remise, les Ă©ventuelles restrictions liĂ©es Ă  la remise de matĂ©riel d’injection stĂ©rile, les difficultĂ©s rapportĂ©es dans la remise de matĂ©riel d’injection stĂ©rile, et enfin sur le retour et l’élimination du matĂ©riel usagĂ©

    Tests of relativity using a microwave resonator

    Get PDF
    The frequencies of a cryogenic sapphire oscillator and a hydrogen maser are compared to set new constraints on a possible violation of Lorentz invariance. We determine the variation of the oscillator frequency as a function of its orientation (Michelson-Morley test) and of its velocity (Kennedy-Thorndike test) with respect to a preferred frame candidate. We constrain the corresponding parameters of the Mansouri and Sexl test theory to ή−ÎČ+1/2=(1.5±4.2)×10−9\delta - \beta + 1/2 = (1.5\pm 4.2) \times 10^{-9} and ÎČ−α−1=(−3.1±6.9)×10−7\beta - \alpha - 1 = (-3.1\pm 6.9) \times 10^{-7} which is equivalent to the best previous result for the former and represents a 30 fold improvement for the latter.Comment: 8 pages, 2 figures, submitted to Physical Review Letters (October 3, 2002
    • 

    corecore