    The Possibilities of Personalized 3D Printed Implants—A Case Series Study

    Full text link
    Background and Objectives: Following the most recent software and 3D printing developments, the use of personalized 3D printed orthopedic implants for treatment of complicated surgical cases has gained more popularity. Today, orthopedic problems that cannot be solved with standard implants may be effectively addressed using personalized prostheses. The aim of this study is to present the designing, modeling and production stages of four different personalized 3D printed prostheses and their application in clinical cases of patients who underwent treatment in various anatomical locations with a precisely specified indication for implantation. Materials and Methods: Based on computed tomography scanning, personalized 3D printed prostheses were designed, produced and used in four patients within a period of three to five days after injury or admission. Results: Early term follow-ups demonstrated good to excellent results. Conclusions: Personalized 3D printed prostheses offer an opportunity for a treatment of choice and provide good anatomical and functional results, shortened surgical time, less complications, and high satisfaction in patients with appropriate indications. The method should be considered primarily for patients with large bone defects, or such indicated for resection. Personalized 3D printed prostheses have the potential to become more common and beneficial in the future

    A Novel Implant for Superior Pubic Ramus Fracture Fixation: Development and a Biomechanical Feasibility Study

    Full text link
    Background and Objectives: Pubic ramus fractures are common in compound pelvic injuries known to have an increased rate of morbidity and mortality along with recurrent and chronic pain, impeding a patient’s quality of life. The current standard treatment of these fractures is percutaneous screw fixation due to its reduced risk of blood loss and shorter surgery times. However, this is an intricate surgical technique associated with high failure rates of up to 15%, related to implant failure and loss of reduction. Therefore, the aim of this biomechanical feasibility study was to develop and test a novel intramedullary splinting implant for fixation of superior pubic ramus fractures (SPRF), and to evaluate its biomechanical viability in comparison with established fixation methods using conventional partially or fully threaded cannulated screws. Materials and Methods: A type II superior pubic ramus fracture according to the Nakatani classification was created in 18 composite hemi-pelvises via a vertical osteotomy with an additional osteotomy in the inferior pubic ramus to isolate the testing of three SPRF fixation techniques performed in 6 semi-pelvises each using either (1) a novel ramus intramedullary splint, (2) a partially threaded ramus screw, or (3) a fully threaded ramus screw. Results: No significant differences were detected among the fixation techniques in terms of initial construct stiffness and number of cycles to failure, p ≥ 0.213. Conclusion: The novel ramus intramedullary splint can be used as an alternative option for treatment of pubic ramus fractures and has the potential to decrease the rate of implant failures due to its minimally invasive implantation procedure

    Single-Stage Externalized Locked Plating for Treatment of Unstable Meta-Diaphyseal Tibial Fractures

    No full text
    (1) Background: Unstable meta-diaphyseal tibial fractures represent a heterogeneous group of injuries. Recently, good clinical results have been reported when applying a technique of externalized locked plating in appropriate cases, highlighting its advantage in terms of less additional tissue injury compared with conventional methods of fracture fixation. The aims of this prospective clinical cohort study were, firstly, to investigate the biomechanical and clinical feasibility and, secondly, to evaluate the clinical and functional outcomes of single-stage externalized locked plating for treatment of unstable, proximal (intra- and extra-articular) and distal (extra-articular), meta-diaphyseal tibial fractures. (2) Methods: Patients, who matched the inclusion criteria of sustaining a high-energy unstable meta-diaphyseal tibial fracture, were identified prospectively for single-stage externalized locked plating at a single trauma hospital in the period from April 2013 to December 2022. (3) Results: Eighteen patients were included in the study. Average follow-up was 21.4 ± 12.3 months, with 94% of the fractures healing without complications. The healing time was 21.1 ± 4.6 weeks, being significantly shorter for patients with proximal extra- versus intra-articular meta-diaphyseal tibial fractures, p = 0.04. Good and excellent functional outcomes in terms of HSS and AOFAS scores, and knee and ankle joints range of motion were observed among all patients, with no registered implant breakage, deep infection, and non-union. (4) Conclusions: Single-stage externalized locked plating of unstable meta-diaphyseal tibial fractures provides adequate stability of fixation with promising clinical results and represents an attractive alternative to the conventional methods of external fixation when inclusion criteria and rehabilitation protocol are strictly followed. Further experimental studies and randomized multicentric clinical trials with larger series of patients are necessary to pave the way of its use in clinical practice

    One-Staged Locked Externalized Plating for the Treatment of Unstable Proximal Metadiaphyseal Tibial Fractures // Заключваща едноетапна външна стабилизация при лечението на нестабилни проксимални метадиафизарни тибиялни фрактури

    No full text
    This prospective study aims to investigate the feasibility and evaluate the results of applying one-staged locked external plating (LEP) in the treatment of unstable tibial fractures with severe soft tissue injury. The biomechanical and biological aspects of LEP with metaphyseal LCP/LISS angle-stable plates were investigated by creating a computational three-dimensional finite element model. The optimal values of the parameters creating sufficient relative stability and conditions for secondary bone healing in aggregate fracture defects up to 20 mm were identified and clinically confirmed. LEP is an innovative, biological approach to the treatment of unstable proximal tibial fractures. A clinical study was conducted, and the results of surgical treatment of a sufficient number of patients with AO/OTA41A2/C2 type fractures resulting from high-energy trauma were evaluated. The results showed that LEP has the characteristics of one-staged elastic fixation and has final functional and clinical outcomes comparable to those of standard methods. LEP is safe and low-risk when strict indications and operative steps are followed. Practical guidelines and an algorithm for the application of a new surgical technique in emergency conditions have been outlined. A technologically simplified, low-risk one-staged surgical approach has been introduced as a treatment.Целта на настоящото проспективно изследване е да се проучат възможностите и да се оценят резултатите от приложението на заключваща едноетапната външна стабилизация(ЗЕВС) при лечението на нестабилните метадиафизарни фрактури на тибията в съчетание с мекотъканна увреда. Проучиха се биомеханичните и биологичните аспекти на ЗЕВС с метафизарни ъгловостабилни плаки LCP/LISS, чрез създаване на изчислителен триизмерен модел по метода на крайните елементи. Установиха и клинично се потвърдиха оптималните стойностите на параметрите, създаващи достатъчна релативна стабилност и условия за вторично костно зарастване при сумарен фрактурен дефект до 20 мм. ЗЕВС е иновативен, щадящ хирургичен подход при лечението на нестабилните тибиялни фрактури. Проведено е клинично проучване и оценка на резултатите от оперативното лечение на достатъчен брой пациенти с фрактури тип АО/ОТА41А2/C2 в резултат на високоенергийни травми. Резултатите показват, че ЗЕВС притежава характеристиките на едноетапна еластична фиксация и е с крайни функционални и клинични резултати, сравними с резултатите при стандартните методи. ЗЕВС е безопасен и нискорисков при спазване на строги индикации и техника на изпълнение. Изведени са практически насоки и алгоритъм за приложението на нова хирургична техника в условия на спешност. Въведен е като лечебна методика в практиката, технологично опростен, ниско рисков едноетапен хирургичен подход, предотвратяващ дълготрайните усложнения и продължителната инвалидизация при тези тежки увреди

    Single-Stage Externalized Locked Plating for Treatment of Unstable Meta-Diaphyseal Tibial Fractures

    Full text link
    (1) Background: Unstable meta-diaphyseal tibial fractures represent a heterogeneous group of injuries. Recently, good clinical results have been reported when applying a technique of externalized locked plating in appropriate cases, highlighting its advantage in terms of less additional tissue injury compared with conventional methods of fracture fixation. The aims of this prospective clinical cohort study were, firstly, to investigate the biomechanical and clinical feasibility and, secondly, to evaluate the clinical and functional outcomes of single-stage externalized locked plating for treatment of unstable, proximal (intra- and extra-articular) and distal (extra-articular), meta-diaphyseal tibial fractures. (2) Methods: Patients, who matched the inclusion criteria of sustaining a high-energy unstable meta-diaphyseal tibial fracture, were identified prospectively for single-stage externalized locked plating at a single trauma hospital in the period from April 2013 to December 2022. (3) Results: Eighteen patients were included in the study. Average follow-up was 21.4 ± 12.3 months, with 94% of the fractures healing without complications. The healing time was 21.1 ± 4.6 weeks, being significantly shorter for patients with proximal extra- versus intra-articular meta-diaphyseal tibial fractures, p = 0.04. Good and excellent functional outcomes in terms of HSS and AOFAS scores, and knee and ankle joints range of motion were observed among all patients, with no registered implant breakage, deep infection, and non-union. (4) Conclusions: Single-stage externalized locked plating of unstable meta-diaphyseal tibial fractures provides adequate stability of fixation with promising clinical results and represents an attractive alternative to the conventional methods of external fixation when inclusion criteria and rehabilitation protocol are strictly followed. Further experimental studies and randomized multicentric clinical trials with larger series of patients are necessary to pave the way of its use in clinical practice

    Single-Stage Externalized Locked Plating for Treatment of Unstable Meta-Diaphyseal Tibial Fractures

    No full text
    (1) Background: Unstable meta-diaphyseal tibial fractures represent a heterogeneous group of injuries. Recently, good clinical results have been reported when applying a technique of externalized locked plating in appropriate cases, highlighting its advantage in terms of less additional tissue injury compared with conventional methods of fracture fixation. The aims of this prospective clinical cohort study were, firstly, to investigate the biomechanical and clinical feasibility and, secondly, to evaluate the clinical and functional outcomes of single-stage externalized locked plating for treatment of unstable, proximal (intra- and extra-articular) and distal (extra-articular), meta-diaphyseal tibial fractures. (2) Methods: Patients, who matched the inclusion criteria of sustaining a high-energy unstable meta-diaphyseal tibial fracture, were identified prospectively for single-stage externalized locked plating at a single trauma hospital in the period from April 2013 to December 2022. (3) Results: Eighteen patients were included in the study. Average follow-up was 21.4 ± 12.3 months, with 94% of the fractures healing without complications. The healing time was 21.1 ± 4.6 weeks, being significantly shorter for patients with proximal extra- versus intra-articular meta-diaphyseal tibial fractures, p = 0.04. Good and excellent functional outcomes in terms of HSS and AOFAS scores, and knee and ankle joints range of motion were observed among all patients, with no registered implant breakage, deep infection, and non-union. (4) Conclusions: Single-stage externalized locked plating of unstable meta-diaphyseal tibial fractures provides adequate stability of fixation with promising clinical results and represents an attractive alternative to the conventional methods of external fixation when inclusion criteria and rehabilitation protocol are strictly followed. Further experimental studies and randomized multicentric clinical trials with larger series of patients are necessary to pave the way of its use in clinical practice

    Percutaneous fixation of intraarticular joint-depression calcaneal fractures with different screw configurations – a biomechanical human cadaveric analysis

    No full text
    Purpose: The aim of this study was to assess the biomechanical performance of different screw configurations for fixation of Sanders type II B joint-depression calcaneal fractures. Methods: Fifteen human cadaveric lower limbs were amputated and Sanders II B fractures were simulated. The specimens were randomized to three groups for fixation with different screw configurations. The calcanei in Group 1 were treated with two parallel longitudinal screws, entering superiorly the Achilles tendon insertion, and two screws fixing the intraarticular posterior facet fracture line. In Group 2 two screws entered the tuberosity inferiorly to the Achilles tendon insertion and two transverse screws fixed the posterior facet. In Group 3 two screws were inserted along the bone axis, one transverse screw fixed the posterior facet and one oblique screw was inserted from the posteroplantar part of the tuberosity supporting the posterolateral part of the posterior facet. All specimens were biomechanically tested to failure under progressively increasing cyclic loading. Results: Initial stiffness did not differ significantly between the groups, P = 0.152. Cycles to 2 mm plantar movement were significantly higher in both Group 1 (15,847 ± 5250) and Group 3 (13,323 ± 4363) compared with Group 2 (4875 ± 3480), P ≤ 0.048. No intraarticular displacement was observed in any group during testing. Conclusions: From a biomechanical perspective, posterior facet support by means of buttress or superiorly inserted longitudinal screws results in less plantar movement between the calcaneal tuberosity and the anterior fragments. Inferiorly inserted longitudinal screws are associated with bigger interfragmentary movements

    Perspectives and consensus among international orthopaedic surgeons during initial and mid-lockdown phases of coronavirus disease

    No full text
    With a lot of uncertainty, unclear, and frequently changing management protocols, COVID-19 has significantly impacted the orthopaedic surgical practice during this pandemic crisis. Surgeons around the world needed closed introspection, contemplation, and prospective consensual recommendations for safe surgical practice and prevention of viral contamination. One hundred orthopaedic surgeons from 50 countries were sent a Google online form with a questionnaire explicating protocols for admission, surgeries, discharge, follow-up, relevant information affecting their surgical practices, difficulties faced, and many more important issues that happened during and after the lockdown. Ten surgeons critically construed and interpreted the data to form rationale guidelines and recommendations. Of the total, hand and microsurgery surgeons (52%), trauma surgeons (32%), joint replacement surgeons (20%), and arthroscopy surgeons (14%) actively participated in the survey. Surgeons from national public health care/government college hospitals (44%) and private/semiprivate practitioners (54%) were involved in the study. Countries had lockdown started as early as January 3, 2020 with the implementation of partial or complete lifting of lockdown in few countries while writing this article. Surgeons (58%) did not stop their surgical practice or clinics but preferred only emergency cases during the lockdown. Most of the surgeons (49%) had three-fourths reduction in their total patients turn-up and the remaining cases were managed by conservative (54%) methods. There was a 50 to 75% reduction in the number of surgeries. Surgeons did perform emergency procedures without COVID-19 tests but preferred reverse transcription polymerase chain reaction (RT-PCR; 77%) and computed tomography (CT) scan chest (12%) tests for all elective surgical cases. Open fracture and emergency procedures (60%) and distal radius (55%) fractures were the most commonly performed surgeries. Surgeons preferred full personal protection equipment kits (69%) with a respirator (N95/FFP3), but in the case of unavailability, they used surgical masks and normal gowns. Regional/local anesthesia (70%) remained their choice for surgery to prevent the aerosolized risk of contaminations. Essential surgical follow-up with limited persons and visits was encouraged by 70% of the surgeons, whereas teleconsultation and telerehabilitation by 30% of the surgeons. Despite the protective equipment, one-third of the surgeons were afraid of getting infected and 56% feared of infecting their near and dear ones. Orthopaedic surgeons in private practice did face 50 to 75% financial loss and have to furlough 25% staff and 50% paramedical persons. Orthopaedics meetings were cancelled, and virtual meetings have become the preferred mode of sharing the knowledge and experiences avoiding human contacts. Staying at home, reading, and writing manuscripts became more interesting and an interesting lifestyle change is seen among the surgeons. Unanimously and without any doubt all accepted the fact that COVID-19 pandemic has reached an unprecedented level where personal hygiene, hand washing, social distancing, and safe surgical practices are the viable antidotes, and they have all slowly integrated these practices into their lives. Strict adherence to local authority recommendations and guidelines, uniform and standardized norms for admission, inpatient, and discharge, mandatory RT-PCR tests before surgery and in selective cases with CT scan chest, optimizing and regularizing the surgeries, avoiding and delaying nonemergency surgeries and follow-up protocols, use of teleconsultations cautiously, and working in close association with the World Health Organization and national health care systems will provide a conducive and safe working environment for orthopaedic surgeons and their fraternity and also will prevent the resurgence of COVID-19
    corecore