23 research outputs found

    Evaluation of Donor and Recipient Characteristics Involved in Descemet Stripping Automated Endothelial Keratoplasty Outcomes

    Get PDF
    Aims: To evaluate both donor and recipient features involved in visual acuity restoring and complication insurgence in eyes that have undergone Descemet stripping automated endothelial keratoplasty (DSAEK). Methods: In this retrospective study, charts of 111 eyes of 96 patients (mean age 70.25 ± 8.58 years) that underwent DSAEK were evaluated. Only Fuch's Distrophy (FD) or Bullous Keratopathy (BK) due to cataract surgery eyes were included. A complete ophthalmic check with endothelial cell density (ECD) and central corneal thickness (CCT) measurement was performed before surgery and at 1, 3, 6, and 12 months follow-up. Each DSAEK was performed by the same well-trained surgeon; only pre-cut lenticules, provided by same Eye Bank, were implanted. Results: A total of 48 (43%) complications have been observed (most of them were 22 partial graft detachments and 17 IOP spikes). At the last follow-up (mean: 8.58 ± 4.09 months), a significant increase (p < 0.05) of best corrected visual acuity (BCVA) was detected. Overall mean BCVA of the eyes evaluated was 0.40 ± 0.43 LogMAR with BK eyes showing a significantly higher improvement (p < 0.05) compared to FD eyes. The only factor showing a significant correlation (p < 0.05) with visual acuity enhancement was the implant of a lenticule thinner than 100 μm. Recipient features significantly (p < 0.05) associated with complications observed after surgery were glaucoma and diabetes mellitus. Conclusion: The use of a graft thinner than 100 μm can provide better visual acuity recovery while recipients affected by glaucoma or diabetes mellitus are more prone to develop complications after surgery

    Correlation between choriocapillaris density and retinal sensitivity in age-related macular degeneration

    Get PDF
    Purpose: The purpose of this study was to investigate the relationship between perfusion of the choriocapillaris (CC) and retinal sensitivity in eyes with intermediate agerelated macular degeneration (iAMD). Methods: This prospective study included patients with iAMD and healthy controls. All enrolled subjects underwent optical coherence tomography angiography (OCT-A) in order to compute the percent perfused choriocapillaris area (PPCA). In patients with iAMD, microperimetry (MP) testing was performed in order to quantify: mean retinal sensitivity (MRS), over an area of 10 degrees; mean macular sensitivity (MMS), over the macular area scanned with OCT-A; and retinal sensitivity (RS) in each macular point. Results: Eighteen eyes of 13 patients were included in the analysis. In addition, 18 eyes of 12 healthy subjects were enrolled as controls. No statistically significant difference (P value > 0.2) was observed in age between patients (73.9 ± 2.0 years) and controls (70.1 ± 2.8 years). We observed significantly lower values of PPCA between patients with iAMD and healthy controls (42.0% ± 3.8% vs. 66.4% ± 3.0%; -Β = 23.8%; P value < 0.001). Among iAMD eyes, higher values of PPCA were significantly associated with higher values of MRS (P value=0.002) and MMS (P value=0.013). Finally, higher values of RS in eachmacular point analyzedwithMPwere significantly (P value<0.001) associated with higher values of PPCA computed in circular regions of interest (ROIs) centered in each analyzed MP point with radii of 0.5 degrees and 1.0 degree. Conclusions: Using OCT-A, we demonstrated a significant association between CC impairment and macular dysfunction, quantified by MP, in iAMD eyes. Translational Relevance: OCT-A could be a useful tool for detecting CC alterations and to monitor disease progression

    Improving accuracy of corneal power measurement with partial coherence interferometry after corneal refractive surgery using a multivariate polynomial approach

    Get PDF
    Background: To improve accuracy of IOLMaster (Carl Zeiss, Jena, Germany) in corneal power measurement after myopic excimer corneal refractive surgery (MECRS) using multivariate polynomial analysis (MPA). Methods: One eye of each of 403 patients (mean age 31.53 ± 8.47 years) was subjected to MECRS for a myopic defect, measured as spherical equivalent, ranging from - 9.50 to - 1 D (mean - 4.55 ± 2.20 D). Each patient underwent a complete eye examination and IOLMaster scan before surgery and at 1, 3 and 6 months follow up. Axial length (AL), flatter keratometry value (K1), steeper keratometry value (K2), mean keratometry value (KM) and anterior chamber depth measured from the corneal endothelium to the anterior surface of the lens (ACD) were used in a MPA to devise a method to improve accuracy of KM measurements. Results: Using AL, K1, K2 and ACD measured after surgery in polynomial degree 2 analysis, mean error of corneal power evaluation after MECRS was + 0.16 ± 0.19 D. Conclusions: MPA was found to be an effective tool in devising a method to improve precision in corneal power evaluation in eyes previously subjected to MECRS, according to our results.Background: To improve accuracy of IOLMaster (Carl Zeiss, Jena, Germany) in corneal power measurement after myopic excimer corneal refractive surgery (MECRS) using multivariate polynomial analysis (MPA). Methods: One eye of each of 403 patients (mean age 31.53 ± 8.47 years) was subjected to MECRS for a myopic defect, measured as spherical equivalent, ranging from - 9.50 to - 1 D (mean - 4.55 ± 2.20 D). Each patient underwent a complete eye examination and IOLMaster scan before surgery and at 1, 3 and 6 months follow up. Axial length (AL), flatter keratometry value (K1), steeper keratometry value (K2), mean keratometry value (KM) and anterior chamber depth measured from the corneal endothelium to the anterior surface of the lens (ACD) were used in a MPA to devise a method to improve accuracy of KM measurements. Results: Using AL, K1, K2 and ACD measured after surgery in polynomial degree 2 analysis, mean error of corneal power evaluation after MECRS was + 0.16 ± 0.19 D. Conclusions: MPA was found to be an effective tool in devising a method to improve precision in corneal power evaluation in eyes previously subjected to MECRS, according to our results

    Le lenti a contatto terapeutiche nel post trapianto di cornea

    No full text
    Comeal transplant is inevitabile when the corneal trasparency is corrupted. . The normal post operatory course islong and it depend to many factors. The ab• normal post operatory course is camc- terized by differents clinical pictures that need to terapy and also to use the contact lens to reduce the inflammation and pam. The choiceof contact lens is an important step to check the clinical pic- ture and to improve the efficiency of the terapy
    corecore