136 research outputs found
Intrinsic Metastabilities in the Charge Configuration of a Double Quantum Dot
We report a thermally activated metastability in a GaAs double quantum dot
exhibiting real-time charge switching in diamond shaped regions of the charge
stability diagram. Accidental charge traps and sensor back action are excluded
as the origin of the switching. We present an extension of the canonical double
dot theory based on an intrinsic, thermal electron exchange process through the
reservoirs, giving excellent agreement with the experiment. The electron spin
is randomized by the exchange process, thus facilitating fast, gate-controlled
spin initialization. At the same time, this process sets an intrinsic upper
limit to the spin relaxation time.Comment: 4 pages, 5 figures (color
GaAs Quantum Dot Thermometry Using Direct Transport and Charge Sensing
We present measurements of the electron temperature using gate defined
quantum dots formed in a GaAs 2D electron gas in both direct transport and
charge sensing mode. Decent agreement with the refrigerator temperature was
observed over a broad range of temperatures down to 10 mK. Upon cooling nuclear
demagnetization stages integrated into the sample wires below 1 mK, the device
electron temperature saturates, remaining close to 10 mK. The extreme
sensitivity of the thermometer to its environment as well as electronic noise
complicates temperature measurements but could potentially provide further
insight into the device characteristics. We discuss thermal coupling
mechanisms, address possible reasons for the temperature saturation and
delineate the prospects of further reducing the device electron temperature.Comment: 8 pages, 3 (color) figure
Photochemical versus Thermal Synthesis of Cobalt Oxyhydroxide Nanocrystals
Photochemical methods facilitate the generation, isolation, and study of metastable nanomaterials having unusual size, composition, and morphology. These harder-to-isolate and highly reactive phases, inaccessible using conventional high-temperature pyrolysis, are likely to possess enhanced and unprecedented chemical, electromagnetic, and catalytic properties. We report a fast, low-temperature and scalable photochemical route to synthesize very small (~3 nm) monodisperse cobalt oxyhydroxide (Co(O)OH) nanocrystals. This method uses readily and commercially available pentaamminechlorocobalt(III) chloride, [Co(NH3) 5Cl]Cl2, under acidic or neutral pH and proceeds under either near-UV (350 nm) or Vis (575 nm) illumination. Control experiments showed that the reaction proceeds at competent rates only in the presence of light, does not involve a free radical mechanism, is insensitive to O 2, and proceeds in two steps: (1) Aquation of [Co(NH3) 5Cl] 2+ to yield [Co(NH3) 5(H2O)] 3+, followed by (2) slow photoinduced release of NH3 from the aqua complex. This reaction is slow enough for Co(O)OH to form but fast enough so that nanocrystals are small (ca. 3 nm). The alternative dark thermal reaction proceeds much more slowly and produces much larger (~250 nm) polydisperse Co(O)OH aggregates. UV-Vis absorption measurements and ab initio calculations yield a Co(O)OH band gap of 1.7 eV. Fast thermal annealing of Co(O)OH nanocrystals leads to Co3O4 nanocrystals with overall retention of nanoparticle size and morphology. Thermogravimetric analysis shows that oxyhydroxide to mixed-oxide phase transition occurs at significantly lower temperatures (up to T = 64 degrees C) for small nanocrystals compared with the bulk
Manual therapy with and without vestibular rehabilitation for cervicogenic dizziness: a systematic review
<p>Abstract</p> <p>Background</p> <p>Manual therapy is an intervention commonly advocated in the management of dizziness of a suspected cervical origin. Vestibular rehabilitation exercises have been shown to be effective in the treatment of unilateral peripheral vestibular disorders, and have also been suggested in the literature as an adjunct in the treatment of cervicogenic dizziness. The purpose of this systematic review is to evaluate the evidence for manual therapy, in conjunction with or without vestibular rehabilitation, in the management of cervicogenic dizziness.</p> <p>Methods</p> <p>A comprehensive search was conducted in the databases Scopus, Mantis, CINHAL and the Cochrane Library for terms related to manual therapy, vestibular rehabilitation and cervicogenic dizziness. Included studies were assessed using the Maastricht-Amsterdam criteria.</p> <p>Results</p> <p>A total of fifteen articles reporting findings from thirteen unique investigations, including five randomised controlled trials and eight prospective, non-controlled cohort studies were included in this review. The methodological quality of the included studies was generally poor to moderate. All but one study reported improvement in dizziness following either unimodal or multimodal manual therapy interventions. Some studies reported improvements in postural stability, joint positioning, range of motion, muscle tenderness, neck pain and vertebrobasilar artery blood flow velocity.</p> <p>Discussion</p> <p>Although it has been argued that manual therapy combined with vestibular rehabilitation may be superior in the treatment of cervicogenic dizziness, there are currently no observational and experimental studies demonstrating such effects. A rationale for combining manual therapy and vestibular rehabilitation in the management of cervicogenic dizziness is presented.</p> <p>Conclusion</p> <p>There is moderate evidence to support the use of manual therapy, in particular spinal mobilisation and manipulation, for cervicogenic dizziness. The evidence for combining manual therapy and vestibular rehabilitation in the management of cervicogenic dizziness is lacking. Further research to elucidate potential synergistic effects of manual therapy and vestibular rehabilitation is strongly recommended.</p
Microplastic-Associated Biofilms: A Comparison of Freshwater and Marine Environments
Microplastics (<5 mm particles) occur within both engineered and natural freshwater ecosystems, including wastewater treatment plants, lakes, rivers, and estuaries. While a significant proportion of microplastic pollution is likely sequestered within freshwater environments, these habitats also constitute an important conduit of microscopic polymer particles to oceans worldwide. The quantity of aquatic microplastic waste is predicted to dramatically increase over the next decade, but the fate and biological implications of this pollution are still poorly understood. A growing body of research has aimed to characterize the formation, composition, and spatiotemporal distribution of microplastic-associated (“plastisphere”) microbial biofilms. Plastisphere microorganisms have been suggested to play significant roles in pathogen transfer, modulation of particle buoyancy, and biodegradation of plastic polymers and co-contaminants, yet investigation of these topics within freshwater environments is at a very early stage. Here, what is known about marine plastisphere assemblages is systematically compared with up-to-date findings from freshwater habitats. Through analysis of key differences and likely commonalities between environments, we discuss how an integrated view of these fields of research will enhance our knowledge of the complex behavior and ecological impacts of microplastic pollutants
Intrinsic metastabilities in the charge configuration of a double quantum dot
We report a thermally activated metastability in a GaAs double quantum dot exhibiting real-time charge switching in diamond shaped regions of the charge stability diagram. Accidental charge traps and sensor backaction are excluded as the origin of the switching. We present an extension of the canonical double dot theory based on an intrinsic, thermal electron exchange process through the reservoirs, giving excellent agreement with the experiment. The electron spin is randomized by the exchange process, thus facilitating fast, gate-controlled spin initialization. At the same time, this process sets an intrinsic upper limit to the spin relaxation time
GaAs Quantum Dot Thermometry Using Direct Transport and Charge Sensing
We present measurements of the electron temperature using gate defined quantum dots formed in a GaAs 2D electron gas in both direct transport and charge sensing mode. Decent agreement with the refrigerator temperature was observed over a broad range of temperatures down to 10 mK. Upon cooling nuclear demagnetization stages integrated into the sample wires below 1 mK, the device electron temperature saturates, remaining close to 10 mK. The extreme sensitivity of the thermometer to its environment as well as electronic noise complicates temperature measurements but could potentially provide further insight into the device characteristics. We discuss thermal coupling mechanisms, address possible reasons for the temperature saturation and delineate the prospects of further reducing the device electron temperature
- …