66 research outputs found

    Clinical applications of robotic technology in vascular and endovascular surgery

    Get PDF
    BackgroundEmerging robotic technologies are increasingly being used by surgical disciplines to facilitate and improve performance of minimally invasive surgery. Robot-assisted intervention has recently been introduced into the field of vascular surgery to potentially enhance laparoscopic vascular and endovascular capabilities. The objective of this study was to review the current status of clinical robotic applications in vascular surgery.MethodsA systematic literature search was performed in order to identify all published clinical studies related to robotic implementation in vascular intervention. Web-based search engines were searched using the keywords “surgical robotics,” “robotic surgery,” “robotics,” “computer assisted surgery,” and “vascular surgery” or “endovascular” for articles published between January 1990 and November 2009. An evaluation and critical overview of these studies is reported. In addition, an analysis and discussion of supporting evidence for robotic computer-enhanced telemanipulation systems in relation to their applications in laparoscopic vascular and endovascular surgery was undertaken.ResultsSeventeen articles reporting on clinical applications of robotics in laparoscopic vascular and endovascular surgery were detected. They were either case reports or retrospective patient series and prospective studies reporting laparoscopic vascular and endovascular treatments for patients using robotic technology. Minimal comparative clinical evidence to evaluate the advantages of robot-assisted vascular procedures was identified. Robot-assisted laparoscopic aortic procedures have been reported by several studies with satisfactory results. Furthermore, the use of robotic technology as a sole modality for abdominal aortic aneurysm repair and expansion of its applications to splenic and renal artery aneurysm reconstruction have been described. Robotically steerable endovascular catheter systems have potential advantages over conventional catheterization systems. Promising results from applications in cardiac interventions and preclinical studies have urged their use in vascular surgery. Although successful applications in endovascular repair of abdominal aortic aneurysm and lower extremity arterial disease have been reported, published clinical experience with the endovascular robot is limited.ConclusionsRobotic technology may enhance vascular surgical techniques given preclinical evidence and early clinical reports. Further clinical studies are required to quantify its advantages over conventional treatments and define its role in vascular and endovascular surgery

    Three-dimensional reconstruction of autologous vein bypass graft distal anastomoses imaged with magnetic resonance: clinical and research applications

    Get PDF
    AbstractHigh-resolution magnetic resonance imaging was combined with computational modeling to create focused three-dimensional reconstructions of the distal anastomotic region of autologous vein peripheral bypass grafts in a preliminary series of patients. Readily viewed on a personal computer or printed as hard copies, a detailed appreciation of in vivo postoperative features of the anastomosis is possible. These reconstructions are suitable for analysis of geometric features, including vessel caliber, tortuosity, anastomotic angles, and planarity. Some potential clinical and research applications of this technique are discussed

    Three-dimensional reconstruction of autologous vein bypass graft distal anastomoses imaged with magnetic resonance: clinical and research applications

    Get PDF
    AbstractHigh-resolution magnetic resonance imaging was combined with computational modeling to create focused three-dimensional reconstructions of the distal anastomotic region of autologous vein peripheral bypass grafts in a preliminary series of patients. Readily viewed on a personal computer or printed as hard copies, a detailed appreciation of in vivo postoperative features of the anastomosis is possible. These reconstructions are suitable for analysis of geometric features, including vessel caliber, tortuosity, anastomotic angles, and planarity. Some potential clinical and research applications of this technique are discussed

    Catheter manipulation analysis for objective performance and technical skills assessment in transcatheter aortic valve implantation

    Get PDF
    Purpose Transcatheter aortic valve implantation (TAVI) demands precise and efficient handling of surgical instruments within the confines of the aortic anatomy. Operational performance and dexterous skills are critical for patient safety, and objective methods are assessed with a number of manipulation features, derived from the kinematic analysis of the catheter/guidewire in fluoroscopy video sequences. Methods A silicon phantom model of a type I aortic arch was used for this study. Twelve endovascular surgeons, divided into two experience groups, experts (n=6) and novices (n=6), performed cannulation of the aorta, representative of valve placement in TAVI. Each participant completed two TAVI experiments, one with conventional catheters and one with the Magellan robotic platform. Video sequences of the fluoroscopic monitor were recorded for procedural processing. A semi-automated tracking software provided the 2D coordinates of the catheter/guidewire tip. In addition, the aorta phantom was segmented in the videos and the shape of the entire catheter was manually annotated in a subset of the available video frames using crowdsourcing. The TAVI procedure was divided into two stages, and various metrics, representative of the catheter’s overall navigation as well as its relative movement to the vessel wall, were developed. Results Experts consistently exhibited lower values of procedure time and dimensionless jerk, and higher average speed and acceleration than novices. Robotic navigation resulted in increased average distance to the vessel wall in both groups, a surrogate measure of safety and reduced risk of embolisation. Discrimination of experience level and types of equipment was achieved with the generated motion features and established clustering algorithms. Conclusions Evaluation of surgical skills is possible through the analysis of the catheter/guidewire motion pattern. The use of robotic endovascular platforms seems to enable more precise and controlled catheter navigation

    A risk-adjusted and anatomically stratified cohort comparison study of open surgery, endovascular techniques and medical management for juxtarenal aortic aneurysms-the UK COMPlex AneurySm Study (UK-COMPASS): a study protocol.

    Get PDF
    Funder: Health Technology Assessment Programme; Grant(s): Award ID: 15/153/02INTRODUCTION: In one-third of all abdominal aortic aneurysms (AAAs), the aneurysm neck is short (juxtarenal) or shows other adverse anatomical features rendering operations more complex, hazardous and expensive. Surgical options include open surgical repair and endovascular aneurysm repair (EVAR) techniques including fenestrated EVAR, EVAR with adjuncts (chimneys/endoanchors) and off-label standard EVAR. The aim of the UK COMPlex AneurySm Study (UK-COMPASS) is to answer the research question identified by the National Institute for Health Research Health Technology Assessment (NIHR HTA) Programme: 'What is the clinical and cost-effectiveness of strategies for the management of juxtarenal AAA, including fenestrated endovascular repair?' METHODS AND ANALYSIS: UK-COMPASS is a cohort study comparing clinical and cost-effectiveness of different strategies used to manage complex AAAs with stratification of physiological fitness and anatomical complexity, with statistical correction for baseline risk and indication biases. There are two data streams. First, a stream of routinely collected data from Hospital Episode Statistics and National Vascular Registry (NVR). Preoperative CT scans of all patients who underwent elective AAA repair in England between 1 November 2017 and 31 October 2019 are subjected to Corelab analysis to accurately identify and include every complex aneurysm treated. Second, a site-reported data stream regarding quality of life and treatment costs from prospectively recruited patients across England. Site recruitment also includes patients with complex aneurysms larger than 55 mm diameter in whom an operation is deferred (medical management). The primary outcome measure is perioperative all-cause mortality. Follow-up will be to a median of 5 years. ETHICS AND DISSEMINATION: The study has received full regulatory approvals from a Research Ethics Committee, the Confidentiality Advisory Group and the Health Research Authority. Data sharing agreements are in place with National Health Service Digital and the NVR. Dissemination will be via NIHR HTA reporting, peer-reviewed journals and conferences. TRIAL REGISTRATION NUMBER: ISRCTN85731188

    Targeted genetic analysis in a large cohort of familial and sporadic cases of aneurysm or dissection of the thoracic aorta

    Get PDF
    PURPOSE: Thoracic aortic aneurysm/aortic dissection (TAAD) is a disorder with highly variable age of onset and phenotype. We sought to determine the prevalence of pathogenic variants in TAAD-associated genes in a mixed cohort of sporadic and familial TAAD patients and identify relevant genotype–phenotype relationships. METHODS: We used a targeted polymerase chain reaction and next-generation sequencing–based panel for genetic analysis of 15 TAAD-associated genes in 1,025 unrelated TAAD cases. RESULTS: We identified 49 pathogenic or likely pathogenic (P/LP) variants in 47 cases (4.9% of those successfully sequenced). Almost half of the variants were in nonsyndromic cases with no known family history of aortic disease. Twenty-five variants were within FBN1 and two patients were found to harbor two P/LP variants. Presence of a related syndrome, younger age at presentation, family history of aortic disease, and involvement of the ascending aorta increased the risk of carrying a P/LP variant. CONCLUSION: Given the poor prognosis of TAAD that is undiagnosed prior to acute rupture or dissection, genetic analysis of both familial and sporadic cases of TAAD will lead to new diagnoses, more informed management, and possibly reduced mortality through earlier, preclinical diagnosis in genetically determined cases and their family members

    Results of the ANCHOR prospective, multicenter registry of EndoAnchors for type Ia endoleaks and endograft migration in patients with challenging anatomy

    Get PDF
    ObjectiveProximal attachment site complications continue to occur after endovascular repair of abdominal aortic aneurysms (EVAR), specifically type Ia endoleak and endograft migration. EndoAnchors (Aptus Endosystems, Sunnyvale, Calif) were designed to enhance endograft proximal fixation and sealing, and the current study was undertaken to evaluate the potential benefit of this treatment.MethodsDuring the 23-month period ending in December 2013, 319 subjects were enrolled at 43 sites in the United States and Europe. EndoAnchors were implanted in 242 patients (75.9%) at the time of an initial EVAR procedure (primary arm) and in 77 patients with an existing endograft and proximal aortic neck complications (revision arm). Technical success was defined as deployment of the desired number of EndoAnchors, adequate penetration of the vessel wall, and absence of EndoAnchor fracture. Procedural success was defined as technical success without a type Ia endoleak at completion angiography. Values are expressed as mean ± standard deviation and interquartile range.ResultsThe 238 male (74.6%) and 81 female (25.4%) subjects had a mean age of 74.1 ± 8.2 years. Aneurysms averaged 58 ± 13 (51-63) mm in diameter at the time of EndoAnchor implantation (core laboratory measurements). The proximal aortic neck averaged 16 ± 13 (7-23) mm in length (42.7% <10 mm and 42.7% conical) and 27 ± 4 mm (25-30 mm) in diameter; infrarenal neck angulation was 24 ± 15 (13-34) degrees. The number of EndoAnchors deployed was 5.8 ± 2.1 (4-7). Technical success was achieved in 303 patients (95.0%) and procedural success in 279 patients (87.5%), 217 of 240 (89.7%) and 62 of 77 (80.5%) in the primary and revision arms, respectively. There were 29 residual type Ia endoleaks (9.1%) at the end of the procedure. During mean follow-up of 9.3 ± 4.7 months, 301 patients (94.4%) were free from secondary procedures. Among the 18 secondary procedures, eight were performed for residual type Ia endoleaks and the others were unrelated to EndoAnchors. There were no open surgical conversions, there were no aneurysm-related deaths, and no aneurysm ruptured during follow-up.ConclusionsUse of EndoAnchors to treat existing and acute type Ia endoleaks and endograft migration was successful in most cases. Prophylactic use of EndoAnchors in patients with hostile aortic neck anatomy appears promising, but definitive conclusions must await longer term follow-up data

    Evaluating the Effects of SARS-CoV-2 Spike Mutation D614G on Transmissibility and Pathogenicity.

    Get PDF
    Global dispersal and increasing frequency of the SARS-CoV-2 spike protein variant D614G are suggestive of a selective advantage but may also be due to a random founder effect. We investigate the hypothesis for positive selection of spike D614G in the United Kingdom using more than 25,000 whole genome SARS-CoV-2 sequences. Despite the availability of a large dataset, well represented by both spike 614 variants, not all approaches showed a conclusive signal of positive selection. Population genetic analysis indicates that 614G increases in frequency relative to 614D in a manner consistent with a selective advantage. We do not find any indication that patients infected with the spike 614G variant have higher COVID-19 mortality or clinical severity, but 614G is associated with higher viral load and younger age of patients. Significant differences in growth and size of 614G phylogenetic clusters indicate a need for continued study of this variant

    Evaluating the Effects of SARS-CoV-2 Spike Mutation D614G on Transmissibility and Pathogenicity

    Get PDF
    Global dispersal and increasing frequency of the SARS-CoV-2 spike protein variant D614G are suggestive of a selective advantage but may also be due to a random founder effect. We investigate the hypothesis for positive selection of spike D614G in the United Kingdom using more than 25,000 whole genome SARS-CoV-2 sequences. Despite the availability of a large dataset, well represented by both spike 614 variants, not all approaches showed a conclusive signal of positive selection. Population genetic analysis indicates that 614G increases in frequency relative to 614D in a manner consistent with a selective advantage. We do not find any indication that patients infected with the spike 614G variant have higher COVID-19 mortality or clinical severity, but 614G is associated with higher viral load and younger age of patients. Significant differences in growth and size of 614G phylogenetic clusters indicate a need for continued study of this variant

    Changes in symptomatology, reinfection, and transmissibility associated with the SARS-CoV-2 variant B.1.1.7: an ecological study

    Get PDF
    Background The SARS-CoV-2 variant B.1.1.7 was first identified in December, 2020, in England. We aimed to investigate whether increases in the proportion of infections with this variant are associated with differences in symptoms or disease course, reinfection rates, or transmissibility. Methods We did an ecological study to examine the association between the regional proportion of infections with the SARS-CoV-2 B.1.1.7 variant and reported symptoms, disease course, rates of reinfection, and transmissibility. Data on types and duration of symptoms were obtained from longitudinal reports from users of the COVID Symptom Study app who reported a positive test for COVID-19 between Sept 28 and Dec 27, 2020 (during which the prevalence of B.1.1.7 increased most notably in parts of the UK). From this dataset, we also estimated the frequency of possible reinfection, defined as the presence of two reported positive tests separated by more than 90 days with a period of reporting no symptoms for more than 7 days before the second positive test. The proportion of SARS-CoV-2 infections with the B.1.1.7 variant across the UK was estimated with use of genomic data from the COVID-19 Genomics UK Consortium and data from Public Health England on spike-gene target failure (a non-specific indicator of the B.1.1.7 variant) in community cases in England. We used linear regression to examine the association between reported symptoms and proportion of B.1.1.7. We assessed the Spearman correlation between the proportion of B.1.1.7 cases and number of reinfections over time, and between the number of positive tests and reinfections. We estimated incidence for B.1.1.7 and previous variants, and compared the effective reproduction number, Rt, for the two incidence estimates. Findings From Sept 28 to Dec 27, 2020, positive COVID-19 tests were reported by 36 920 COVID Symptom Study app users whose region was known and who reported as healthy on app sign-up. We found no changes in reported symptoms or disease duration associated with B.1.1.7. For the same period, possible reinfections were identified in 249 (0·7% [95% CI 0·6–0·8]) of 36 509 app users who reported a positive swab test before Oct 1, 2020, but there was no evidence that the frequency of reinfections was higher for the B.1.1.7 variant than for pre-existing variants. Reinfection occurrences were more positively correlated with the overall regional rise in cases (Spearman correlation 0·56–0·69 for South East, London, and East of England) than with the regional increase in the proportion of infections with the B.1.1.7 variant (Spearman correlation 0·38–0·56 in the same regions), suggesting B.1.1.7 does not substantially alter the risk of reinfection. We found a multiplicative increase in the Rt of B.1.1.7 by a factor of 1·35 (95% CI 1·02–1·69) relative to pre-existing variants. However, Rt fell below 1 during regional and national lockdowns, even in regions with high proportions of infections with the B.1.1.7 variant. Interpretation The lack of change in symptoms identified in this study indicates that existing testing and surveillance infrastructure do not need to change specifically for the B.1.1.7 variant. In addition, given that there was no apparent increase in the reinfection rate, vaccines are likely to remain effective against the B.1.1.7 variant. Funding Zoe Global, Department of Health (UK), Wellcome Trust, Engineering and Physical Sciences Research Council (UK), National Institute for Health Research (UK), Medical Research Council (UK), Alzheimer's Society
    corecore