8 research outputs found

    Antibody Responses to SARS-CoV-2 Infection—Comparative Determination of Seroprevalence in Two High-Throughput Assays versus a Sensitive Spike Protein ELISA

    Get PDF
    From MDPI via Jisc Publications RouterHistory: accepted 2021-11-07, pub-electronic 2021-11-11Publication status: PublishedRobust assay development for SARS-CoV-2 serological testing requires assessment of asymptomatic and non-hospitalised individuals to determine if assays are sensitive to mild antibody responses. Our study evaluated the performance characteristics of two high-throughput SARS-CoV-2 IgG nucleocapsid assays (Abbott Architect and Roche) and The Binding Site (TBS) Anti-Spike IgG/A/M ELISA kit in samples from healthcare workers (HCWs). The 252 samples were collected from multi-site NHS trusts and analysed for SARS-CoV-2 serology. Assay performance was evaluated between these three platforms and ROC curves were used to redefine the Abbott threshold. Concordance between Abbott and TBS was 66%. Any discrepant results were analysed using Roche, which showed 100% concordance with TBS. Analysis conducted in HCWs within 58 days post-PCR result demonstrated 100% sensitivity for both Abbott and Roche. Longitudinal analysis for >100 days post-PCR led to sensitivity of 77.2% and 100% for Abbott and Roche, respectively. A redefined Abbott threshold (0.64) increased sensitivity to 90%, producing results comparable to TBS and Roche. The manufacturer’s threshold set by Abbott contributes to lower sensitivity and elevated false-negative occurrences. Abbott performance improved upon re-optimisation of the cut-off threshold. Our findings provided evidence that TBS can be used as bespoke alternative for SARS-CoV-2 serology analysis where high-throughput platforms are not feasible on site

    A National Survey of Hereditary Angioedema and Acquired C1 Inhibitor Deficiency in the United Kingdom

    Get PDF
    Background: Detailed demographic data on people with hereditary angioedema (HAE) and acquired C1 inhibitor deficiency in the United Kingdom are relatively limited. Better demographic data would be beneficial in planning service provision, identifying areas of improvement, and improving care./ Objective: To obtain more accurate data on the demographics of HAE and acquired C1 inhibitor deficiency in the United Kingdom, including treatment modalities and services available to patients./ Methods: A survey was distributed to all centers in the United Kingdom that look after patients with HAE and acquired C1 inhibitor deficiency to collect these data./ Results: The survey identified 1152 patients with HAE-1/2 (58% female and 92% type 1), 22 patients with HAE with normal C1 inhibitor, and 91 patients with acquired C1 inhibitor deficiency. Data were provided by 37 centers across the United Kingdom. This gives a minimum prevalence of 1:59,000 for HAE-1/2 and 1:734,000 for acquired C1 inhibitor deficiency in the United Kingdom. A total of 45% of patients with HAE were on long-term prophylaxis (LTP) with the most used medication being danazol (55% of all patients on LTP). Eighty-two percent of patients with HAE had a home supply of acute treatment with C1 inhibitor or icatibant. A total of 45% of patients had a supply of icatibant and 56% had a supply of C1 inhibitor at home./ Conclusions: Data obtained from the survey provide useful information about the demographics and treatment modalities used in HAE and acquired C1 inhibitor deficiency in the United Kingdom. These data are useful for planning service provision and improving services for these patients

    Antibody Responses to SARS-CoV-2 Infection—Comparative Determination of Seroprevalence in Two High-Throughput Assays versus a Sensitive Spike Protein ELISA

    No full text
    Robust assay development for SARS-CoV-2 serological testing requires assessment of asymptomatic and non-hospitalised individuals to determine if assays are sensitive to mild antibody responses. Our study evaluated the performance characteristics of two high-throughput SARS-CoV-2 IgG nucleocapsid assays (Abbott Architect and Roche) and The Binding Site (TBS) Anti-Spike IgG/A/M ELISA kit in samples from healthcare workers (HCWs). The 252 samples were collected from multi-site NHS trusts and analysed for SARS-CoV-2 serology. Assay performance was evaluated between these three platforms and ROC curves were used to redefine the Abbott threshold. Concordance between Abbott and TBS was 66%. Any discrepant results were analysed using Roche, which showed 100% concordance with TBS. Analysis conducted in HCWs within 58 days post-PCR result demonstrated 100% sensitivity for both Abbott and Roche. Longitudinal analysis for >100 days post-PCR led to sensitivity of 77.2% and 100% for Abbott and Roche, respectively. A redefined Abbott threshold (0.64) increased sensitivity to 90%, producing results comparable to TBS and Roche. The manufacturer’s threshold set by Abbott contributes to lower sensitivity and elevated false-negative occurrences. Abbott performance improved upon re-optimisation of the cut-off threshold. Our findings provided evidence that TBS can be used as bespoke alternative for SARS-CoV-2 serology analysis where high-throughput platforms are not feasible on site

    The United Kingdom Primary Immune Deficiency (UKPID) registry 2012 to 2017

    Get PDF
    This is the second report of the United Kingdom Primary Immunodeficiency (UKPID) registry. The registry will be a decade old in 2018 and, as of August 2017, had recruited 4758 patients encompassing 97% of immunology centres within the United Kingdom. This represents a doubling of recruitment into the registry since we reported on 2229 patients included in our first report of 2013. Minimum PID prevalence in the United Kingdom is currently 5·90/100 000 and an average incidence of PID between 1980 and 2000 of 7·6 cases per 100 000 UK live births. Data are presented on the frequency of diseases recorded, disease prevalence, diagnostic delay and treatment modality, including haematopoietic stem cell transplantation (HSCT) and gene therapy. The registry provides valuable information to clinicians, researchers, service commissioners and industry alike on PID within the United Kingdom, which may not otherwise be available without the existence of a well‐established registry

    COVID-19 in patients with primary and secondary immunodeficiency: The United Kingdom experience

    No full text
    Background As of November 2020, severe acute respiratory syndrome coronavirus 2 has resulted in 55 million infections worldwide and more than 1.3 million deaths from coronavirus disease 2019 (COVID-19). Outcomes following severe acute respiratory syndrome coronavirus 2 infection in individuals with primary immunodeficiency (PID) or symptomatic secondary immunodeficiency (SID) remain uncertain. Objectives We sought to document the outcomes of individuals with PID or symptomatic SID following COVID-19 in the United Kingdom. Methods At the start of the COVID-19 pandemic, the United Kingdom Primary Immunodeficiency Network established a registry of cases to collate the nationwide outcomes of COVID-19 in individuals with PID or symptomatic SID and determine risk factors associated with morbidity and mortality from COVID-19 in these patient groups. Results A total of 100 patients had been enrolled by July 1, 2020, 60 with PID, 7 with other inborn errors of immunity including autoinflammatory diseases and C1 inhibitor deficiency, and 33 with symptomatic SID. In individuals with PID, 53.3% (32 of 60) were hospitalized, the infection-fatality ratio was 20.0% (12 of 60), the case-fatality ratio was 31.6% (12 of 38), and the inpatient mortality was 37.5% (12 of 32). Individuals with SID had worse outcomes than those with PID; 75.8% (25 of 33) were hospitalized, the infection-fatality ratio was 33.3% (11 of 33), the case-fatality ratio was 39.2% (11 of 28), and inpatient mortality was 44.0% (11 of 25). Conclusions In comparison to the general population, adult patients with PID and symptomatic SID display greater morbidity and mortality from COVID-19. This increased risk must be reflected in public health guidelines to adequately protect vulnerable patients from exposure to the virus

    Outcomes following SARS-CoV-2 infection in patients with primary and secondary immunodeficiency in the UK.

    Get PDF
    In March 2020, the United Kingdom Primary Immunodeficiency Network (UKPIN) established a registry of cases to collate the outcomes of individuals with PID and SID following SARS-CoV-2 infection and treatment. A total of 310 cases of SARS-CoV-2 infection in individuals with PID or SID have now been reported in the UK. The overall mortality within the cohort was 17.7% (n = 55/310). Individuals with CVID demonstrated an infection fatality rate (IFR) of 18.3% (n = 17/93), individuals with PID receiving IgRT had an IFR of 16.3% (n = 26/159) and individuals with SID, an IFR of 27.2% (n = 25/92). Individuals with PID and SID had higher inpatient mortality and died at a younger age than the general population. Increasing age, low pre-SARS-CoV-2 infection lymphocyte count and the presence of common co-morbidities increased the risk of mortality in PID. Access to specific COVID-19 treatments in this cohort was limited: only 22.9% (n = 33/144) of patients admitted to the hospital received dexamethasone, remdesivir, an anti-SARS-CoV-2 antibody-based therapeutic (e.g. REGN-COV2 or convalescent plasma) or tocilizumab as a monotherapy or in combination. Dexamethasone, remdesivir, and anti-SARS-CoV-2 antibody-based therapeutics appeared efficacious in PID and SID. Compared to the general population, individuals with PID or SID are at high risk of mortality following SARS-CoV-2 infection. Increasing age, low baseline lymphocyte count, and the presence of co-morbidities are additional risk factors for poor outcome in this cohort
    corecore