21 research outputs found

    Cost-effectiveness of implantable cardiac devices in patients with systolic heart failure

    Get PDF
    Objective To evaluate the cost-effectiveness of implantable cardioverter defibrillators (ICDs), cardiac resynchronisation therapy pacemakers (CRT-Ps) and combination therapy (CRT-D) in patients with heart failure with reduced ejection fraction based on a range of clinical characteristics. Methods Individual patient data from 13 randomised trials were used to inform a decision analytical model. A series of regression equations were used to predict baseline all-cause mortality, hospitalisation rates and health-related quality of life and device-related treatment effects. Clinical variables used in these equations were age, QRS duration, New York Heart Association (NYHA) class, ischaemic aetiology and left bundle branch block (LBBB). A UK National Health Service perspective and a lifetime time horizon were used. Benefits were expressed as quality-adjusted life-years (QALYs). Results were reported for 24 subgroups based on LBBB status, QRS duration and NYHA class. Results At a threshold of £30 000 per QALY gained, CRT-D was cost-effective in 10 of the 24 subgroups including all LBBB morphology patients with NYHA I/II/III. ICD is cost-effective for all non-NYHA IV patients with QRS duration 120 ms and for NYHA I/II non-LBBB morphology patients with QRS duration between 120 ms and 149 ms. CRT-P was also cost-effective in all NYHA III/IV patients with QRS duration 120 ms. Device therapy is cost-effective in most patient groups with LBBB at a threshold of £20 000 per QALY gained. Results were robust to altering key model parameters. Conclusions At a threshold of £30 000 per QALY gained, CRT-D is cost-effective in a far wider group than previously recommended in the UK. In some subgroups ICD and CRT-P remain the cost-effective choice

    Prognosis of Myocardial Damage in Sarcoidosis Patients With Preserved Left Ventricular Ejection Fraction

    No full text
    BackgroundCardiac sarcoidosis is associated with an increased risk of heart failure and sudden death, but its risk in patients with preserved left ventricular ejection fraction is unknown. Using cardiovascular magnetic resonance in patients with extracardiac sarcoidosis and preserved left ventricular ejection fraction, we sought to (1) determine the prevalence of cardiac sarcoidosis or associated myocardial damage, defined by the presence of late gadolinium enhancement (LGE), (2) quantify their risk of death/ventricular tachycardia (VT), and (3) identify imaging-based covariates that predict who is at greatest risk of death/VT.Methods and resultsParameters of left and right ventricular function and LGE burden were measured in 205 patients with left ventricular ejection fraction >50% and extracardiac sarcoidosis who underwent cardiovascular magnetic resonance for LGE evaluation. The association between covariates and death/VT in the entire group and within the LGE+ group was determined using Cox proportional hazard models and time-dependent receiver-operator curves analysis. Forty-one of 205 patients (20%) had LGE; 12 of 205 (6%) died or had VT during follow-up; of these, 10 (83%) were in the LGE+ group. In the LGE+ group (1) the rate of death/VT per year was >20× higher than LGE- (4.9 versus 0.2%, P<0.01); (2) death/VT were associated with a greater burden of LGE (14±11 versus 5±5%, P<0.01) and right ventricular dysfunction (right ventricular EF 45±12 versus 53±28%, P=0.04). LGE burden was the best predictor of death/VT (area under the receiver-operating characteristics curve, 0.80); for every 1% increase of LGE burden, the hazard of death/VT increased by 8%.ConclusionsSarcoidosis patients with LGE are at significant risk for death/VT, even with preserved left ventricular ejection fraction. Increased LGE burden and right ventricular dysfunction can identify LGE+ patients at highest risk of death/VT
    corecore