17 research outputs found

    Structure-function correlates of vision loss in neuromyelitis optica spectrum disorders

    Get PDF
    Optic neuritis (ON) in neuromyelitis optica spectrum disorders (NMOSD) regularly leads to more profound vision loss compared to multiple sclerosis (MS) and myelin-oligodendrocyte-glycoprotein-antibody associated disease (MOGAD). Here we investigate ON-related vision loss in NMOSD compared to MS and MOGAD in order to identify neuroaxonal and retinal contributors to visual dysfunction. In this retrospective study we included patients with aquaporin-4-antibody seropositive NMOSD (n = 28), MOGAD (n = 14), MS (n = 29) and controls (n = 14). We assessed optic nerve damage and fovea morphometry by optical coherence tomography. Visual function was assessed as high (HCVA) and low contrast visual acuity (LCVA), and visual fields' mean deviation (MD). In all diseases, lower visual function was associated with peripapillary retinal nerve fiber layer (pRNFL) and ganglion cell and inner plexiform layer (GCIP) thinning following a broken stick model, with pRNFL and GCIP cutoff point at ca. 60 µm. HCVA loss per µm pRNFL and GCIP thinning was stronger in NMOSD compared with MOGAD. Foveal inner rim volume contributed to MD and LCVA in NMOSD eyes, only. Together these data supports that visual dysfunction in NMOSD is associated with neuroaxonal damage beyond the effect seen in MS and MOGAD. A primary retinopathy, respectively Müller cell pathology, may contribute to this effect

    Cohort profile: a collaborative multicentre study of retinal optical coherence tomography in 539 patients with neuromyelitis optica spectrum disorders (CROCTINO)

    Get PDF
    PURPOSE: Optical coherence tomography (OCT) captures retinal damage in neuromyelitis optica spectrum disorders (NMOSD). Previous studies investigating OCT in NMOSD have been limited by the rareness and heterogeneity of the disease. The goal of this study was to establish an image repository platform, which will facilitate neuroimaging studies in NMOSD. Here we summarise the profile of the Collaborative OCT in NMOSD repository as the initial effort in establishing this platform. This repository should prove invaluable for studies using OCT to investigate NMOSD. PARTICIPANTS: The current cohort includes data from 539 patients with NMOSD and 114 healthy controls. These were collected at 22 participating centres from North and South America, Asia and Europe. The dataset consists of demographic details, diagnosis, antibody status, clinical disability, visual function, history of optic neuritis and other NMOSD defining attacks, and OCT source data from three different OCT devices. FINDINGS TO DATE: The cohort informs similar demographic and clinical characteristics as those of previously published NMOSD cohorts. The image repository platform and centre network continue to be available for future prospective neuroimaging studies in NMOSD. For the conduct of the study, we have refined OCT image quality criteria and developed a cross-device intraretinal segmentation pipeline. FUTURE PLANS: We are pursuing several scientific projects based on the repository, such as analysing retinal layer thickness measurements, in this cohort in an attempt to identify differences between distinct disease phenotypes, demographics and ethnicities. The dataset will be available for further projects to interested, qualified parties, such as those using specialised image analysis or artificial intelligence applications

    Retinal optical coherence tomography in neuromyelitis optica

    Get PDF
    BACKGROUND AND OBJECTIVES: To determine optic nerve and retinal damage in aquaporin-4 antibody (AQP4-IgG)-seropositive neuromyelitis optica spectrum disorders (NMOSD) in a large international cohort after previous studies have been limited by small and heterogeneous cohorts. METHODS: The cross-sectional Collaborative Retrospective Study on retinal optical coherence tomography (OCT) in neuromyelitis optica collected retrospective data from 22 centers. Of 653 screened participants, we included 283 AQP4-IgG-seropositive patients with NMOSD and 72 healthy controls (HCs). Participants underwent OCT with central reading including quality control and intraretinal segmentation. The primary outcome was thickness of combined ganglion cell and inner plexiform (GCIP) layer; secondary outcomes were thickness of peripapillary retinal nerve fiber layer (pRNFL) and visual acuity (VA). RESULTS: Eyes with ON (NMOSD-ON, N = 260) or without ON (NMOSD-NON, N = 241) were assessed compared with HCs (N = 136). In NMOSD-ON, GCIP layer (57.4 ± 12.2 μm) was reduced compared with HC (GCIP layer: 81.4 ± 5.7 μm, p < 0.001). GCIP layer loss (-22.7 μm) after the first ON was higher than after the next (-3.5 μm) and subsequent episodes. pRNFL observations were similar. NMOSD-NON exhibited reduced GCIP layer but not pRNFL compared with HC. VA was greatly reduced in NMOSD-ON compared with HC eyes, but did not differ between NMOSD-NON and HC. DISCUSSION: Our results emphasize that attack prevention is key to avoid severe neuroaxonal damage and vision loss caused by ON in NMOSD. Therapies ameliorating attack-related damage, especially during a first attack, are an unmet clinical need. Mild signs of neuroaxonal changes without apparent vision loss in ON-unaffected eyes might be solely due to contralateral ON attacks and do not suggest clinically relevant progression but need further investigation

    Serial Branches

    No full text
    The question whether contemporary information technology with its potential for individual fabrication allows for a new approach to the uniqueness that is offered to us by nature was discussed within a 8-day workshop. 19 students of KADK explored the performative potential of naturally angled and forked wood – a desired material until 19th century, but swept away by industrialization and its standardization of processes and materials

    The dimensions of context and its role in mobile information retrieval

    No full text

    Serial Branches: Strategies to activate the performative capacity of naturally grown wooden form with contemporary information technology

    No full text
    The question whether contemporary information technology with its potential for individual fabrication allows for a new approach to the uniqueness that is offered to us by nature was discussed within a 8-day workshop. 19 students of KADK explored the performative potential of naturally angled and forked wood \u96 a desired material until 19th century, but swept away by industrialization and its standardization of processes and materials

    Automatic quality evaluation as assessment standard for optical coherence tomography

    No full text
    Retinal optical coherence tomography (OCT) is increasingly used for quantifying neuroaxonal damage in diseases of the central nervous system such as multiple sclerosis. High-quality OCT images are essential for accurate intraretinal segmentation and for correct quantification of retinal thickness changes. The quality of OCT images depends largely on the operator and patient compliance. Quality evaluation is time-consuming, and current OCT image quality criteria depend on the experience of the grader and are therefore subjective. The automatic graderindependent real-time feedback system for quality evaluation of retinal OCT images, AQuA, was developed to standardize quality evaluation and data accuracy. It classifies by signal quality, anatomical completeness and segmentation plausibility and has been validated by experienced graders. However, it is currently limited to OCT scans taken with one device from a single vendor. The aim of this work is to improve the capability of the AQuA quality classifier to generalize to new data, by developing a convolutional neural network (CNN), AQuANet. Moreover, this CNN may serve as a basic quality classifier, that can be adapted to specific problems by transfer learning. AQuANet is trained on A-Scan batches with quality labels automatically obtained with AQuA. Thus, a large set of training data of about 13000 A-Scan batches could be used, leading to an accuracy of 99.53%
    corecore