156 research outputs found
Bioengineering, augmented reality, and robotic surgery in vascular surgery: A literature review
Biomedical engineering integrates a variety of applied sciences with life sciences to improve human health and reduce the invasiveness of surgical procedures. Technological advances, achieved through biomedical engineering, have contributed to significant improvements in the field of vascular and endovascular surgery. This paper aims to review the most cutting-edge technologies of the last decade involving the use of augmented reality devices and robotic systems in vascular surgery, highlighting benefits and limitations. Accordingly, two distinct literature surveys were conducted through the PubMed database: the first review provides a comprehensive assessment of augmented reality technologies, including the different techniques available for the visualization of virtual content (11 papers revised); the second review collects studies with bioengineering content that highlight the research trend in robotic vascular surgery, excluding works focused only on the clinical use of commercially available robotic systems (15 papers revised). Technological flow is constant and further advances in imaging techniques and hardware components will inevitably bring new tools for a clinical translation of innovative therapeutic strategies in vascular surgery
The Management of Ruptured Abdominal Aortic Aneurysms: An Ongoing Challenge
Background: despite improvements in the diagnosis and treatment of elective AAAs, ruptured abdominal aortic aneurysms (RAAAs) continue to cause a substantial number of deaths. The choice between an open or endovascular approach remains a challenge, as does postoperative complications in survivors. The aim of this manuscript is to offer an overview of the contemporary management of RAAA patients, with a focus on preoperative and intraoperative factors that could help surgeons provide more appropriate treatment. Methods: we performed a search on MEDLINE, Embase, and Scopus from 1 January 1985 to 1 May 2023 and reviewed SVS and ESVS guidelines. A total of 278 articles were screened, but only those with data available on ruptured aneurysms' incidence and prevalence, preoperative scores, and mortality rates after emergency endovascular or open repair for ruptured AAA were included in the narrative synthesis. Articles were not restricted due to the designs of the studies. Results: the centralization of RAAAs has improved outcomes after both surgical and endovascular repair. Preoperative mortality risk scores and knowledge of intraoperative factors influencing mortality could help surgeons with decision-making, although there is still no consensus about the best treatment. Complications continue to be an issue in patients surviving intervention. Conclusions: RAAA still represents a life-threatening condition, with high mortality rates. Effective screening and centralization matched with adequate preoperative risk-benefit assessment may improve outcomes
Emergent management of diabetic foot problems in the modern era: Improving outcomes
Limb amputation is a consequence, and the leading complication, of diabetic foot ulcers. Prevention depends on prompt diagnosis and management. Patients should be managed by multidisciplinary teams and efforts should be focused on limb salvage (“time is tissue”). The diabetic foot service should be organized in a way to meet the patient's clinical needs, with the diabetic foot centers at the highest level of this structure. Surgical management should be multimodal and include not only revascularization, but also surgical and biological debridement, minor amputations, and advanced wound therapy. Medical treatment, including an adequate antimicrobial therapy, has a key role in the eradication of infection and should be guided by microbiologists and infection disease physicians with special interest in bone infection. Input from diabetologists, radiologists, orthopedic teams (foot and ankle), orthotists, podiatrists, physiotherapists, and prosthetics, as well as psychological counseling, is required to make the service comprehensive. After the acute phase, a well-structured, pragmatic follow-up program is necessary to adequately manage the patients with the aim to detect earlier potential failures of the revascularization or antimicrobial therapy. Considering the cost and societal impact of diabetic foot problems, health care providers should provide resources to manage the burden of diabetic foot problems in the modern er
Laparoscopic treatment of splenic artery aneurysms
OBJECTIVES:
The purpose of this study was to report a series of 16 consecutive patients who underwent laparoscopic treatment of splenic artery aneurysms.
METHODS:
Over a period of 8 years, patients were selected for the laparoscopic option by a team of specialists that included the vascular surgeon, the interventional radiologist, and the laparoscopic surgeon. The mean size of the aneurysm was 32 mm and most was located at the splenic hilum. They were twice as common in females as in males. Ultrasonography with color Doppler function was used to define intraoperative strategy.
RESULTS:
The laparoscopic treatment entailed excision of the aneurysm or its exclusion, usually reserved for distally located lesions. In one patient, laparoscopic resection and robotic anastomosis of the splenic artery was performed to re-establish flow to the spleen. In two patients, the intraoperative decision was added to combine a laparoscopic splenectomy due to insufficient residual arterial flow to the spleen. There was no conversion, or need for re-operation or related mortality. Analysis of intraoperative arterial flow data avoided unnecessary splenectomy following noncritical reduction of flow to the spleen.
CONCLUSIONS:
The use of intraoperative color Doppler ultrasonography is essential in deciding the appropriate procedure and whether the spleen should be removed or saved. Early control of the splenic artery proximal to the aneurysm can limit the risk of conversion due to intraoperative bleeding. Distally located aneurysms are more difficult to manage and entail a higher risk of associated splenectomy. The laparoscopic option offers some advantages over the endovascular treatment in selected patients. A multidisciplinary approach is the key to a successful treatment of this uncommon disease
Alternative Nuclear Imaging Tools for Infection Imaging
Purpose of Review Cardiovascular infections are serious disease associated with high morbidity and mortality. Their diagnosis is challenging, requiring a proper management for a prompt recognition of the clinical manifestations, and a multidisciplinary approach involving cardiologists, cardiothoracic surgeons, infectious diseases specialist, imagers, and microbiologists. Imaging plays a central role in the diagnostic workout, including molecular imaging techniques. In this setting, two different strategies might be used to image infections: the first is based on the use of agents targeting the microorganism responsible for the infection. Alternatively, we can target the components of the pathophysiological changes of the inflammatory process and/or the host response to the infectious pathogen can be considered. Understanding the strength and limitations of each strategy is crucial to select the most appropriate imaging tool. Recent Findings Currently, multislice computed tomography (MSCT) and nuclear imaging (F-18-fluorodeoxyglucose positron emission tomography/computed tomography, and leucocyte scintigraphy) are part of the diagnostic strategies. The main role of nuclear medicine imaging (PET/CT and SPECT/CT) is the confirmation of valve/CIED involvement and/or associated perivalvular infection and the detection of distant septic embolism. Proper patients' preparation, imaging acquisition, and reconstruction as well as imaging reading are crucial to maximize the diagnostic information. In this manuscript, we described the use of molecular imaging techniques, in particular WBC imaging, in patients with infective endocarditis, cardiovascular implantable electronic device infections, and infections of composite aortic graft, underlying the strength and limitations of such approached as compared to the other imaging modalities
A technical review of bail-out procedures to place Najuta stent-graft into the ascending aorta
BackgroundThe Najuta stent-graft (Kawasumi Laboratories Inc., Tokyo, Japan) is usually easily advanced to the correct deployment position in the ascending aorta thanks to the pre-curved delivery J-sheath with all fenestrations automatically oriented towards the supra-aortic vessels. Aortic arch anatomy and delivery system stiffness could however represent limitations for proper endograft advancement, especially when the aortic arch bends sharply. The aim of this technical note is to report a series of bail-out procedures that could be useful to overcome the difficulties encountered during the Najuta stent-graft advancement up to the ascending aorta.Main bodyThe insertion, positioning and deployment of a Najuta stent-graft requires a through-and-through guidewire technique using a .035 '' 400 cm hydrophilic nitinol guidewire (Radifocus (TM) Guidewire M Non-Vascular, Terumo Corporation, Tokyo, Japan) with right brachial and both femoral accesses. When standard maneuver to put the endograft tip into the aortic arch, some bail-out procedures can be applied to obtain proper positioning. Five techniques are described into the text: positioning of a coaxial extra-stiff guidewire; positioning of a long introducer sheath down to the aortic root from the right brachial access; inflation of a balloon inside the ostia of the supra-aortic vessels; inflation of a balloon inside the aortic arch (coaxial to the device); and transapical access technique. This is a troubleshooting guide for allowing physicians to overcome various difficulties with the Najuta endograft as well as for other similar devices.Short conclusionTechnical issues in advancing the delivery system of Najuta stent-graft could occur. Therefore, the rescue procedures described in this technical note could be useful to guarantee the correct positioning and deployment of the stent-graft
Rupture Of Abdominal Aortic Aneurysm Due To Endograft Infection After Endovascular Aneurysm Repair (EVAR): A Case Report
Endograft infection is a rare event, with few reports in the literature.
This report describes delayed infection of an aortic endoprosthesis that eventually resulted in abdominal aortic aneurysm (AAA) rupture. The procedure was performed in an angiographic suite. In the postoperative period the patient developed a central venous line infection. This appears to be the first recognized and reported case in which the infected aortic neck completely dilated due to the radial force of the stent graft
Ensemble deep learning for the prediction of proficiency at a virtual simulator for robot-assisted surgery
Background
Artificial intelligence (AI) has the potential to enhance patient safety in surgery, and all its aspects, including education and training, will derive considerable benefit from AI. In the present study, deep-learning models were used to predict the rates of proficiency acquisition in robot-assisted surgery (RAS), thereby providing surgical programs directors information on the levels of the innate ability of trainees to facilitate the implementation of flexible personalized training.
Methods
176 medical students, without prior experience with surgical simulators, were trained to reach proficiency in five tasks on a virtual simulator for RAS. Ensemble deep neural networks (DNN) models were developed and compared with other ensemble AI algorithms, i.e., random forests and gradient boosted regression trees (GBRT).
Results
DNN models achieved a higher accuracy than random forests and GBRT in predicting time to proficiency, 0.84 vs. 0.70 and 0.77, respectively (Peg board 2), 0.83 vs. 0.79 and 0.78 (Ring walk 2), 0.81 vs 0.81 and 0.80 (Match board 1), 0.79 vs. 0.75 and 0.71 (Ring and rail 2), and 0.87 vs. 0.86 and 0.84 (Thread the rings 2). Ensemble DNN models outperformed random forests and GBRT in predicting number of attempts to proficiency, with an accuracy of 0.87 vs. 0.86 and 0.83, respectively (Peg board 2), 0.89 vs. 0.88 and 0.89 (Ring walk 2), 0.91 vs. 0.89 and 0.89 (Match board 1), 0.89 vs. 0.87 and 0.83 (Ring and rail 2), and 0.96 vs. 0.94 and 0.94 (Thread the rings 2).
Conclusions
Ensemble DNN models can identify at an early stage the acquisition rates of surgical technical proficiency of trainees and identify those struggling to reach the required expected proficiency level
- …