9 research outputs found

    International nosocomial infection control consortium (INICC) report, data summary of 36 countries, for 2004-2009

    Get PDF
    The results of a surveillance study conducted by the International Nosocomial Infection Control Consortium (INICC) from January 2004 through December 2009 in 422 intensive care units (ICUs) of 36 countries in Latin America, Asia, Africa, and Europe are reported. During the 6-year study period, using Centers for Disease Control and Prevention (CDC) National Healthcare Safety Network (NHSN; formerly the National Nosocomial Infection Surveillance system [NNIS]) definitions for device-associated health care-associated infections, we gathered prospective data from 313,008 patients hospitalized in the consortium's ICUs for an aggregate of 2,194,897 ICU bed-days. Despite the fact that the use of devices in the developing countries' ICUs was remarkably similar to that reported in US ICUs in the CDC's NHSN, rates of device-associated nosocomial infection were significantly higher in the ICUs of the INICC hospitals; the pooled rate of central line-associated bloodstream infection in the INICC ICUs of 6.8 per 1,000 central line-days was more than 3-fold higher than the 2.0 per 1,000 central line-days reported in comparable US ICUs. The overall rate of ventilator-associated pneumonia also was far higher (15.8 vs 3.3 per 1,000 ventilator-days), as was the rate of catheter-associated urinary tract infection (6.3 vs. 3.3 per 1,000 catheter-days). Notably, the frequencies of resistance of Pseudomonas aeruginosa isolates to imipenem (47.2% vs 23.0%), Klebsiella pneumoniae isolates to ceftazidime (76.3% vs 27.1%), Escherichia coli isolates to ceftazidime (66.7% vs 8.1%), Staphylococcus aureus isolates to methicillin (84.4% vs 56.8%), were also higher in the consortium's ICUs, and the crude unadjusted excess mortalities of device-related infections ranged from 7.3% (for catheter-associated urinary tract infection) to 15.2% (for ventilator-associated pneumonia). Copyright © 2012 by the Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved

    Early experience with COVID-19 patients in a private tertiary hospital in the Philippines: Implications on surge capacity, healthcare systems response, and clinical care

    No full text
    Background: Our healthcare institution was one of the first to see SARS CoV-2 cases in the country. We describe the early COVID-19 experience of a private hospital in the Philippines and discuss the healthcare system response in the setting of surge capacity. Methods: We reviewed the medical records of adult COVID-19 hospitalized patients admitted in March 2020. We reported their demographic and clinical characteristics using descriptive statistics. Results: Of 40 patients admitted, 23 (57.5%) were male and 19 (47.5%) were aged <60 years. Most (n = 27, 67.5%) had moderate-risk, 9 (22.5%) had high-risk, and 4 (10%) had low-risk COVID-19. SARS-CoV-2 testing took 5.5 (range 1–10) days. Overall mortality rate was 6/40 (15.0%). Clinical cure was documented in all low-risk patients, 25 (92.6%) moderate-risk patients, and only 1 (11.1%) high-risk patient. In response to the surge, the hospital rapidly introduced one-way traffic systems, dedicated screening, triage and Emergency Department areas for COVID-19, a clinical pathway, engineering controls, patient cohorting, and strict infection prevention and control measures. Conclusion: Majority of patients recovered from COVID-19. Older age and high-risk pneumonia were associated with poor outcomes. Adaptations to hospital structure and staff were quickly made in response to surge capacity, although our response was hampered by prolonged time to COVID-19 confirmation. Our study underscores the urgent need for rapid adaptive response by the healthcare system to address the surge of cases

    Nosocomial Infection Control Consortium (INICC)

    No full text
    We aimed to evaluate the impact of a multidimensional infection control strategy for the reduction of the incidence of catheter-associated urinary tract infection (CAUTI) in patients hospitalized in adult intensive care units (AICUs) of hospitals which are members of the International Nosocomial Infection Control Consortium (INICC), from 40 cities of 15 developing countries: Argentina, Brazil, China, Colombia, Costa Rica, Cuba, India, Lebanon, Macedonia, Mexico, Morocco, Panama, Peru, Philippines, and Turkey.We conducted a prospective before-after surveillance study of CAUTI rates on 56,429 patients hospitalized in 57 AICUs, during 360,667 bed-days. The study was divided into the baseline period (Phase 1) and the intervention period (Phase 2). In Phase 1, active surveillance was performed. In Phase 2, we implemented a multidimensional infection control approach that included: (1) a bundle of preventive measures, (2) education, (3) outcome surveillance, (4) process surveillance, (5) feedback of CAUTI rates, and (6) feedback of performance. The rates of CAUTI obtained in Phase 1 were compared with the rates obtained in Phase 2, after interventions were implemented.We recorded 253,122 urinary catheter (UC)-days: 30,390 in Phase 1 and 222,732 in Phase 2. In Phase 1, before the intervention, the CAUTI rate was 7.86 per 1,000 UC-days, and in Phase 2, after intervention, the rate of CAUTI decreased to 4.95 per 1,000 UC-days [relative risk (RR) 0.63 (95 % confidence interval [CI] 0.55-0.72)], showing a 37 % rate reduction.Our study showed that the implementation of a multidimensional infection control strategy is associated with a significant reduction in the CAUTI rate in AICUs from developing countries

    Impact of International Nosocomial Infection Control Consortium (INICC) strategy on central line-associated bloodstream infection rates in the intensive care units of 15 developing countries

    No full text
    BACKGROUND. The International Nosocomial Infection Control Consortium (INICC) was established in 15 developing countries to reduce infection rates in resource-limited hospitals by focusing on education and feedback of outcome surveillance (infection rates) and process surveillance (adherence to infection control measures). We report a time-sequence analysis of the effectiveness of this approach in reducing rates of central line-associated bloodstream infection (CLABSI) and associated deaths in 86 intensive care units with a minimum of 6-month INICC membership. METHODS. Pooled CLABSI rates during the first 3 months (baseline) were compared with rates at 6-month intervals during the first 24 months in 53,719 patients (190,905 central line-days). Process surveillance results at baseline were compared with intervention period data. RESULTS. During the first 6 months, CLABSI incidence decreased by 33% (from 14.5 to 9.7 CLABSIs per 1,000 central line-days). Over the first 24 months there was a cumulative reduction from baseline of 54% (from 16.0 to 7.4 CLABSIs per 1,000 central line-days; relative risk, 0.46 [95% confidence interval, 0.33-0.63]; P < .001). The number of deaths in patients with CLABSI decreased by 58%. During the intervention period, hand hygiene adherence improved from 50% to 60% (P < .001); the percentage of intensive care units that used maximal sterile barriers at insertion increased from 45% to 85% (P < .001 ), that adopted chlorhexidine for antisepsis increased from 7% to 27% (P=.018 ), and that sought to remove unneeded catheters increased from 37% to 83% (P=.004); and the duration of central line placement decreased from 4.1 to 3.5 days (P < .001). CONCLUSIONS. Education, performance feedback, and outcome and process surveillance of CLABSI rates significantly improved infection control adherence, reducing the CLABSI incidence by 54% and the number of CLABSI-associated deaths by 58% in INICC hospitals during the first 2 years. © 2010 by The Society for Healthcare Epidemiology of America. All rights reserved

    Erratum: International Nosocomial Infection Control Consortium report, data summary of 43 countries for 2007-2012. Device-associated module (American Journal of Infection Control (2014) 42 (942-956))

    No full text

    International Nosocomial Infection Control Consortiu (INICC) report, data summary of 43 countries for 2007-2012. Device-associated module

    No full text
    We report the results of an International Nosocomial Infection Control Consortium (INICC) surveillance study from January 2007-December 2012 in 503 intensive care units (ICUs) in Latin America, Asia, Africa, and Europe. During the 6-year study using the Centers for Disease Control and Prevention's (CDC) U.S. National Healthcare Safety Network (NHSN) definitions for device-associated health care–associated infection (DA-HAI), we collected prospective data from 605,310 patients hospitalized in the INICC's ICUs for an aggregate of 3,338,396 days. Although device utilization in the INICC's ICUs was similar to that reported from ICUs in the U.S. in the CDC's NHSN, rates of device-associated nosocomial infection were higher in the ICUs of the INICC hospitals: the pooled rate of central line–associated bloodstream infection in the INICC's ICUs, 4.9 per 1,000 central line days, is nearly 5-fold higher than the 0.9 per 1,000 central line days reported from comparable U.S. ICUs. The overall rate of ventilator-associated pneumonia was also higher (16.8 vs 1.1 per 1,000 ventilator days) as was the rate of catheter-associated urinary tract infection (5.5 vs 1.3 per 1,000 catheter days). Frequencies of resistance of Pseudomonas isolates to amikacin (42.8% vs 10%) and imipenem (42.4% vs 26.1%) and Klebsiella pneumoniae isolates to ceftazidime (71.2% vs 28.8%) and imipenem (19.6% vs 12.8%) were also higher in the INICC's ICUs compared with the ICUs of the CDC's NHSN
    corecore