    Experimental pre-clinical assessment of the primary stability of two cementless femoral knee components

    Get PDF
    Item does not contain fulltextTo achieve long-lasting fixation of cementless implants, an adequate primary stability is required. We aimed to compare primary stability of a new cementless femoral knee component (Attune(R)) against a conventional implant (LCS(R)) under different loading conditions. Six pairs of femora were prepared following the normal surgical procedure. Calibrated CT-scans and 3D-optical scans of the bones were obtained to measure bone mineral density (BMD) and cut accuracy, respectively. Micromotions were measured in nine regions of interest at the bone-implant interface using digital image correlation. The reconstructions were subjected to the implant-specific's peak tibiofemoral load of gait and a deep knee bend loading profiles. Afterwards, the implants were pushed-off at a flexion angle of 150 degrees . Micromotions of Attune were significantly lower than LCS under both loading conditions (P </= 0.001). Cut accuracy did not affect micromotions, and BMD was only a significant factor affecting the micromotions under simplified gait loading. No significant difference was found in high-flex push-off force, but Attune required a significantly higher load to generate excessive micromotions during push-off. Parallel anterior and posterior bone cuts in the LCS versus the tapered bone cuts of the Attune may explain the difference between the two designs. Additionally, the rims at the borders of the LCS likely reduced the area of contact with the bone for the LCS, which may have affected the initial fixation

    Interface micromechanics of transverse sections from retrieved cemented hip reconstructions: an experimental and finite element comparison.

    Get PDF
    Contains fulltext : 108389.pdf (publisher's version ) (Open Access)In finite element analysis (FEA) models of cemented hip reconstructions, it is crucial to include the cement-bone interface mechanics. Recently, a micromechanical cohesive model was generated which reproduces the behavior of the cement-bone interface. The goal was to investigate whether this cohesive model was directly applicable on a macro level. From transverse sections of retrieved cemented hip reconstructions, two FEA-models were generated. The cement-bone interface was modeled with cohesive elements. A torque was applied and the cement-bone interface micromotions, global stiffness and stem translation were monitored. A sensitivity analysis was performed to investigate whether the cohesive model could be improved. All results were compared with experimental findings. That the original cohesive model resulted in a too compliant macromechanical response; the motions were too large and the global stiffness too small. When the cohesive model was modified, the match with the experimental response improved considerably.1 augustus 201
    corecore