51 research outputs found
Variable profiles of plasma pulses generated from high-k dielectric barrier discharge
With a specific design of a high-k dielectric barrier discharge, we observed plasma pulses with variable spatial profiles as a consequence of excitation by a high-voltage pulse at different pressures. The dependence of the profile of the generated plasma pulses on the charging voltage and the operating gas (air) pressure is described and the description of their temporal and spatial build-up mechanism is given. We demonstrate that the profile variation of the plasma pulses is caused by the co-existence of dipole switching-based electron emission and field electron emission from triple junctions. Finally, we propose a scheme describing the interaction of these two electron emission mechanisms that leads to the pressure dependence of plasma pulse profile
Patient-specific stopping power calibration for proton therapy planning based on single-detector proton radiography.
A simple robust optimizer has been developed that can produce patient-specific calibration curves to convert x-ray computed tomography (CT) numbers to relative stopping powers (HU-RSPs) for proton therapy treatment planning. The difference between a digitally reconstructed radiograph water-equivalent path length (DRRWEPL) map through the x-ray CT dataset and a proton radiograph (set as the ground truth) is minimized by optimizing the HU-RSP calibration curve. The function of the optimizer is validated with synthetic datasets that contain no noise and its robustness is shown against CT noise. Application of the procedure is then demonstrated on a plastic and a real tissue phantom, with proton radiographs produced using a single detector. The mean errors using generic/optimized calibration curves between the DRRWEPL map and the proton radiograph were 1.8/0.4% for a plastic phantom and -2.1/ - 0.2% for a real tissue phantom. It was then demonstrated that these optimized calibration curves offer a better prediction of the water equivalent path length at a therapeutic depth. We believe that these promising results are suggestive that a single proton radiograph could be used to generate a patient-specific calibration curve as part of the current proton treatment planning workflow
Dose ratio proton radiography using the proximal side of the Bragg peak
Purpose: In recent years there has been a movement towards single-detector proton radiography, due to its potential ease of implementation within the clinical environment. One such single-detector technique is the dose ratio method, in which the dose maps from two pristine Bragg peaks are recorded beyond the patient. To date, this has only been investigated on the distal side of the lower energy Bragg peak, due to the sharp fall-off. We investigate the limits and applicability of the dose ratio method on the proximal side of the lower energy Bragg peak, which has the potential to allow a much wider range of water-equivalent thicknesses (WET) to be imaged. Comparisons are made with the use of the distal side of the Bragg peak. Methods: Using the analytical approximation for the Bragg peak we generated theoretical dose ratio curves for a range of energy pairs, and then determined how an uncertainty in the dose ratio would translate to a spread in the WET estimate. By defining this spread as the accuracy one could achieve in the WET estimate, we were able to generate look-up graphs of the range on the proximal side of the Bragg peak that one could reliably use. These were dependent on the energy pair, noise level in the dose ratio image and the required accuracy in the WET. Using these look-up graphs we investigated the applicability of the technique for a range of patient treatment sites. We validated the theoretical approach with experimental measurements using a complementary metal oxide semiconductor active pixel sensor (CMOS APS), by imaging a small sapphire sphere in a high energy proton beam. Results: Provided the noise level in the dose ratio image was 1% or less, a larger spread of WETs could be imaged using the proximal side of the Bragg peak (max 5.31 cm) compared to the distal side (max 2.42 cm). In simulation it was found that, for a pediatric brain, it is possible to use the technique to image a region with a square field equivalent size of 7.6 cm2, for a required accuracy in the WET of 3 mm and a 1% noise level in the dose ratio image. The technique showed limited applicability for other patient sites. The CMOS APS demonstrated a good accuracy, with a root-mean-square-error of 1.6 mm WET. The noise in the measured images was found to be σ =1.2% (standard deviation) and theoretical predictions with a 1.96σ noise level showed good agreement with the measured errors. Conclusions: After validating the theoretical approach with measurements, we have shown that the use of the proximal side of the Bragg peak when performing dose ratio imaging is feasible, and allows for a wider dynamic range than when using the distal side. The dynamic range available increases as the demand on the accuracy of the WET decreases. The technique can only be applied to clinical sites with small maximum WETs such as for pediatric brains
Plasma Panel Sensors for Particle and Beam Detection
The plasma panel sensor (PPS) is an inherently digital, high gain, novel
variant of micropattern gas detectors inspired by many operational and
fabrication principles common to plasma display panels (PDPs). The PPS is
comprised of a dense array of small, plasma discharge, gas cells within a
hermetically-sealed glass panel, and is assembled from non-reactive,
intrinsically radiation-hard materials such as glass substrates, metal
electrodes and mostly inert gas mixtures. We are developing the technology to
fabricate these devices with very low mass and small thickness, using gas gaps
of at least a few hundred micrometers. Our tests with these devices demonstrate
a spatial resolution of about 1 mm. We intend to make PPS devices with much
smaller cells and the potential for much finer position resolutions. Our PPS
tests also show response times of several nanoseconds. We report here our
results in detecting betas, cosmic-ray muons, and our first proton beam tests.Comment: 2012 IEEE NS
Plasma panel‐based radiation detectors
The plasma panel sensor (PPS) is a gaseous micropattern radiation detector under current development. It has many operational and fabrication principles common to plasma display panels. It comprises a dense matrix of small, gas plasma discharge cells within a hermetically sealed panel. As in plasma display panels, it uses nonreactive, intrinsically radiation‐hard materials such as glass substrates, refractory metal electrodes, and mostly inert gas mixtures. We are developing these devices primarily as thin, low‐mass detectors with gas gaps from a few hundred microns to a few millimeters. The PPS is a high gain, inherently digital device with the potential for fast response times, fine position resolution (<50‐µm RMS) and low cost. In this paper, we report on prototype PPS experimental results in detecting betas, protons, and cosmic muons, and we extrapolate on the PPS potential for applications including the detection of alphas, heavy ions at low‐to‐medium energy, thermal neutrons, and X‐rays.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/98325/1/jsid151.pd
Glassy dynamics in mono-, di-, and tri-propylene glycol: From the alpha- to the fast beta-relaxation
We present a thorough characterization of the glassy dynamics of three
propylene glycols (mono-, di- and trimer) by broadband dielectric spectroscopy.
By covering a frequency range of more than 15 decades, we have access to the
entire variety of dynamic processes typical for glassy dynamics. These results
add three more molecular glass formers to the sparse list of materials for
which real broadband spectra, including the region of the fast beta-process,
are available. Some first analyses of the various observed dynamic processes
are provided
Social Isolation over puberty disrupts the estrous cycle and reduces sexual receptivity in female mice
editorial reviewe
- …