    Morphological features of the photoplethysmographic signal: a new approach to characterize the microcirculatory response to photobiomodulation

    Get PDF
    Introduction and Objectives: Advanced analysis of the morphological features of the photoplethysmographic (PPG) waveform may provide greater understanding of mechanisms of action of photobiomodulation (PBM). Photobiomodulation is a non-ionizing, red to near-infrared irradiation shown to induce peripheral vasodilatation, promote wound healing, and reduce pain. Using laser Doppler flowmetry combined with thermal imaging we found previously in a clinical study that PBM stimulates microcirculatory blood flow and that baseline palm skin temperature determines, at least in part, why some individuals respond favorably to PBM while others do not. “Responders” (n = 12) had a skin temperature range of 33°C–37.5°C, while “non-responders” (n = 8) had “cold” or “hot” skin temperature (<33°C or >37.5°C respectively). The continuous PPG signals recorded from the index fingers of both hands in the original clinical study were subjected to advanced post-acquisitional analysis in the current study, aiming to identify morphological features that may improve the accuracy of discrimination between potential responders and non-responders to PBM.Methods: The PPG signals were detrended by subtracting the lower envelope from the raw signal. The Root Mean Square (RMS) and Entropy features were extracted as were two additional morphological features -- Smoothness and number of local extrema per PPG beat (#Extrema). These describe the signal jaggedness and were developed specifically for this study. The Wilcoxon test was used for paired comparisons. Correlations were determined by the Spearman correlation test (rs).Results: The PPG waveforms of responders to PBM had increased amplitude and decreased jaggedness (Baseline vs. 10’ post-irradiation: Entropy, 5.0 ± 1.3 vs. 3.9 ± 1.1, p = 0.012; #Extrema, 4.0 ± 1.1 vs. 3.0 ± 1.6, p = 0.009; RMS, 1.6 ± 0.9 vs. 2.3 ± 1.2, p = 0.004; Smoothness, 0.10 ± 0.05 vs. 0.19 ± 0.16, p = 0.016). In addition, unilateral irradiation resulted in a bilateral response, although the response of the contralateral, non-irradiated hand was shorter in duration and lower in magnitude. Although subjects with ‘cold,’ or ‘hot,’ baseline skin temperature appeared to have morphologically distinct PPG waveforms, representing vasoconstriction and vasodilatation, these were not affected by PBM irradiation.Conclusion: This pilot study indicates that post-acquisitional analysis of morphological features of the PPG waveform provides new measures for the exploration of microcirculation responsiveness to PBM

    Relative and Absolute Risk to Guide the Management of Pulse Pressure, an Age-Related Cardiovascular Risk Factor

    Get PDF
    BACKGROUND Pulse pressure (PP) reflects the age-related stiffening of the central arteries, but no study addressed the management of the PP-related risk over the human lifespan. METHODS In 4663 young (18-49 years) and 7185 older adults (≄50 years), brachial PP was recorded over 24-hour. Total mortality and all major cardiovascular events combined (MACE) were co-primary endpoints. Cardiovascular death, coronary events and stroke were secondary endpoints. RESULTS In young adults (median follow-up, 14.1 years; mean PP, 45.1 mmHg), greater PP was not associated with absolute risk; the endpoint rates were ≀2.01 per 1000 person-years. The adjusted hazard ratios expressed per 10-mmHg PP increments were less than unity (P≀0.027) for MACE (0.67; 95% CI, 0.47-0.96) and cardiovascular death (0.33; 95% CI, 0.11-0.75). In older adults (median follow-up, 13.1 years; mean PP, 52.7 mmHg), the endpoint rates, expressing absolute risk, ranged from 22.5 to 45.4 per 1000 person-years and the adjusted hazard ratios, reflecting relative risk, from 1.09 to 1.54 (P3-fold from age 55 to 75 years, whereas absolute risk rose by a factor 3. CONCLUSIONS From 50 years onwards, the PP-related relative risk decreases, whereas absolute risk increases. From a lifecourse perspective, young adulthood provides a window of opportunity to manage risk factors and prevent target organ damage as forerunner of premature death and MACE. In older adults, treatment should address absolute risk, thereby extending life in years and qualit

    Correlating Ambulatory Blood Pressure Measurements With Arterial Stiffness: A Conceptual Inconsistency?

    No full text

    DataSheet1_Morphological features of the photoplethysmographic signal: a new approach to characterize the microcirculatory response to photobiomodulation.PDF

    No full text
    Introduction and Objectives: Advanced analysis of the morphological features of the photoplethysmographic (PPG) waveform may provide greater understanding of mechanisms of action of photobiomodulation (PBM). Photobiomodulation is a non-ionizing, red to near-infrared irradiation shown to induce peripheral vasodilatation, promote wound healing, and reduce pain. Using laser Doppler flowmetry combined with thermal imaging we found previously in a clinical study that PBM stimulates microcirculatory blood flow and that baseline palm skin temperature determines, at least in part, why some individuals respond favorably to PBM while others do not. “Responders” (n = 12) had a skin temperature range of 33°C–37.5°C, while “non-responders” (n = 8) had “cold” or “hot” skin temperature (37.5°C respectively). The continuous PPG signals recorded from the index fingers of both hands in the original clinical study were subjected to advanced post-acquisitional analysis in the current study, aiming to identify morphological features that may improve the accuracy of discrimination between potential responders and non-responders to PBM.Methods: The PPG signals were detrended by subtracting the lower envelope from the raw signal. The Root Mean Square (RMS) and Entropy features were extracted as were two additional morphological features -- Smoothness and number of local extrema per PPG beat (#Extrema). These describe the signal jaggedness and were developed specifically for this study. The Wilcoxon test was used for paired comparisons. Correlations were determined by the Spearman correlation test (rs).Results: The PPG waveforms of responders to PBM had increased amplitude and decreased jaggedness (Baseline vs. 10’ post-irradiation: Entropy, 5.0 ± 1.3 vs. 3.9 ± 1.1, p = 0.012; #Extrema, 4.0 ± 1.1 vs. 3.0 ± 1.6, p = 0.009; RMS, 1.6 ± 0.9 vs. 2.3 ± 1.2, p = 0.004; Smoothness, 0.10 ± 0.05 vs. 0.19 ± 0.16, p = 0.016). In addition, unilateral irradiation resulted in a bilateral response, although the response of the contralateral, non-irradiated hand was shorter in duration and lower in magnitude. Although subjects with ‘cold,’ or ‘hot,’ baseline skin temperature appeared to have morphologically distinct PPG waveforms, representing vasoconstriction and vasodilatation, these were not affected by PBM irradiation.Conclusion: This pilot study indicates that post-acquisitional analysis of morphological features of the PPG waveform provides new measures for the exploration of microcirculation responsiveness to PBM.</p

    Effects of gravity-induced upper-limb blood pressure changes on wave transmission and arterial radial waveform

    No full text
    Background: Local blood pressure (BP) changes induced by arm tilting may influence pressure wave transmission and reflection. We investigated the effects of upper-limb tilting on radial augmentation index (rAIx) and related central measures [aortic augmentation index (aAIx)]. Methods: In 45 volunteers (age 49 ± 19 years), supine brachial BP and radial artery waveforms were obtained by applanation tonometry with the dominant arm stretched and gently supported in three different positions: at the heart level, with the BP cuff 15 cm above heart level (approximately +30°), and 15 cm below heart level (-30°). Results: Brachial SBP/DBP was 120/68 ± 17/8 mmHg. Mean arterial pressure changed predictably with arm tilting (99 ± 12 mmHg at -30°, 88 ± 10 mmHg at 0°, 77 ± 11 mmHg at +30°, all P < 0.001). rAIx decreased at -30° (69 ± 22%), and increased at +30° (93 ± 20%) compared with 0° (82 ± 20%, all P less than 0.001). Changes in rAIx (value at +30° minus value at -30°) showed an inverse relationship with age (r = -0.32, P = 0.03). Heart rate, BP and rAIx did not change in the contralateral arm, which was held at the heart level during the examination. aAIx followed the same pattern as rAIx (123 ± 27% at -30°, 144 ± 33% at +30°, 136 ± 31% at 0°, all P less than 0.001); changes in rAIx and aAIx were strongly related each other (r = 0.82, P < 0.001). Conclusion: Acute gravitational upper-limb BP changes generate opposite, profound changes in rAIx, and major artifactual changes in aAIx. These findings provide a rationale for recommending to keep the upper limb at the heart level during radial waveform assessment.8 page(s