10 research outputs found

    Factors Associated with Revision Surgery after Internal Fixation of Hip Fractures

    Get PDF
    Background: Femoral neck fractures are associated with high rates of revision surgery after management with internal fixation. Using data from the Fixation using Alternative Implants for the Treatment of Hip fractures (FAITH) trial evaluating methods of internal fixation in patients with femoral neck fractures, we investigated associations between baseline and surgical factors and the need for revision surgery to promote healing, relieve pain, treat infection or improve function over 24 months postsurgery. Additionally, we investigated factors associated with (1) hardware removal and (2) implant exchange from cancellous screws (CS) or sliding hip screw (SHS) to total hip arthroplasty, hemiarthroplasty, or another internal fixation device. Methods: We identified 15 potential factors a priori that may be associated with revision surgery, 7 with hardware removal, and 14 with implant exchange. We used multivariable Cox proportional hazards analyses in our investigation. Results: Factors associated with increased risk of revision surgery included: female sex, [hazard ratio (HR) 1.79, 95% confidence interval (CI) 1.25-2.50; P = 0.001], higher body mass index (fo

    Determinants of urinary output response to IV furosemide in acute kidney injury: a pharmacokinetic/pharmacodynamic study

    No full text
    Objectives: This study assessed the determinants of urinary output response to furosemide in acute kidney injury; specifically, whether the response is related to altered pharmacokinetics or pharmacodynamics. Design: Prospective cohort. Setting: Tertiary ICU. Patients: Thirty critically ill patients with acute kidney injury without preexisting renal impairment or recent diuretic exposure. Intervention: A single dose of IV furosemide. Measurements and Main Results: Baseline markers of intravascular volume status were obtained prior to administering furosemide. Six-hour creatinine clearance, hourly plasma/urinary furosemide concentrations, and hourly urinary output were used to assess furosemide pharmacokinetics/pharmacodynamics parameters. Of 30 patients enrolled, 11 had stage-1 (37%), nine had stage-2 (30%), and 10 had stage-3 (33%) Acute Kidney Injury Network acute kidney injury. Seventy-three percent were septic, 47% required norepinephrine, and 53% were mechanically ventilated. Urinary output doubled in 20 patients (67%) following IV furosemide. Measured creatinine clearance was strongly associated with the amount of urinary furosemide excreted and was the only reliable predictor of the urinary output after furosemide (area under the receiver-operating-characteristic curve, 0.75; 95% CI, 0.57-0.93). In addition to an altered pharmacokinetics (p < 0.01), a reduced pharmacodynamics response to furosemide also became important when creatinine clearance was reduced to less than 40 mL/min/1.73 m 2 (p = 0.01). Acute kidney injury staging and markers of intravascular volume, including central venous pressure, brain-natriuretic-peptide concentration, and fractional urinary sodium excretion were not predictive of urinary output response to furosemide. Conclusions: The severity of acute kidney injury, as reflected by the measured creatinine clearance, alters both pharmacokinetics and pharmacodynamics of furosemide in acute kidney injury, and was the only reliable predictor of the urinary output response to furosemide in acute kidney injury

    Before Roe v. Wade: Voices that Shaped the Abortion Debate before the Supreme Court's Ruling

    No full text

    Fracture fixation in the operative management of hip fractures (FAITH): an international, multicentre, randomised controlled trial

    No full text
    Background Reoperation rates are high after surgery for hip fractures. We investigated the effect of a sliding hip screw versus cancellous screws on the risk of reoperation and other key outcomes. Methods For this international, multicentre, allocation concealed randomised controlled trial, we enrolled patients aged 50 years or older with a low-energy hip fracture requiring fracture fixation from 81 clinical centres in eight countries. Patients were assigned by minimisation with a centralised computer system to receive a single large-diameter screw with a side-plate (sliding hip screw) or the present standard of care, multiple small-diameter cancellous screws. Surgeons and patients were not blinded but the data analyst, while doing the analyses, remained blinded to treatment groups. The primary outcome was hip reoperation within 24 months after initial surgery to promote fracture healing, relieve pain, treat infection, or improve function. Analyses followed the intention-to-treat principle. This study was registered with ClinicalTrials.gov, number NCT00761813. Findings Between Mar

    Femoral Neck Shortening After Hip Fracture Fixation Is Associated With Inferior Hip Function : Results From the FAITH Trial

    No full text

    Pathological Changes in the Elderly Human Brain

    No full text

    Fracture fixation in the operative management of hip fractures (FAITH): an international, multicentre, randomised controlled trial

    No full text
    corecore