14 research outputs found

    Comparison between First- and Second-Generation Cryoballoon for Paroxysmal Atrial Fibrillation Ablation

    Get PDF
    Introduction. Cryoballoon (CB) ablation has emerged as a novel treatment for pulmonary vein isolation (PVI) for patients with paroxysmal atrial fibrillation (PAF). The second-generation Arctic Front Advance (ADV) was redesigned with technical modifications aiming at procedural and outcome improvements. We aimed to compare the efficacy of the two different technologies over a long-term follow-up. Methods. A total of 120 patients with PAF were enrolled. Sixty patients underwent PVI using the first-generation CB and 60 patients with the ADV catheter. All patients were evaluated over a follow-up period of 2 years. Results. There were no significant differences between the two groups of patients. Procedures performed with the first-generation CB showed longer fluoroscopy time (36.3±16.8 versus 14.2±13.5 min, resp.; p=0.00016) and longer procedure times as well (153.1±32 versus 102±24.8 min, resp.; p=0.019). The overall long-term success was significantly different between the two groups (68.3 versus 86.7%, resp.; p=0.017). No differences were found in the lesion areas of left and right PV between the two groups (resp., p=0.61 and 0.57). There were no significant differences in procedural-related complications. Conclusion. The ADV catheter compared to the first-generation balloon allows obtaining a significantly higher success rate after a single PVI procedure during the long-term follow-up. Fluoroscopy and procedural times were significantly shortened using the ADV catheter

    Comparison between First-and Second-Generation Cryoballoon for Paroxysmal Atrial Fibrillation Ablation

    Get PDF
    Introduction. Cryoballoon (CB) ablation has emerged as a novel treatment for pulmonary vein isolation (PVI) for patients with paroxysmal atrial fibrillation (PAF). The second-generation Arctic Front Advance (ADV) was redesigned with technical modifications aiming at procedural and outcome improvements. We aimed to compare the efficacy of the two different technologies over a long-term follow-up. Methods. A total of 120 patients with PAF were enrolled. Sixty patients underwent PVI using the firstgeneration CB and 60 patients with the ADV catheter. All patients were evaluated over a follow-up period of 2 years. Results. There were no significant differences between the two groups of patients. Procedures performed with the first-generation CB showed longer fluoroscopy time (36.3 ± 16.8 versus 14.2 ± 13.5 min, resp.; = 0.00016) and longer procedure times as well (153.1 ± 32 versus 102±24.8 min, resp.; = 0.019). The overall long-term success was significantly different between the two groups (68.3 versus 86.7%, resp.; = 0.017). No differences were found in the lesion areas of left and right PV between the two groups (resp., = 0.61 and 0.57). There were no significant differences in procedural-related complications. Conclusion. The ADV catheter compared to the first-generation balloon allows obtaining a significantly higher success rate after a single PVI procedure during the long-term follow-up. Fluoroscopy and procedural times were significantly shortened using the ADV catheter

    Early Clinical Outcomes and Advantages of a Novel-Size Adjustable Second-Generation Cryoballoon: A Proof-of-Concept Study

    No full text
    (1) Background/Objective Balloon-guided catheter ablation (CA) has emerged as an alternative option for atrial fibrillation (AF) management. The recent introduction of a novel-size adjustable second-generation cryoballoon (CB) system offers innovations, but clinical outcomes remain unexplored. This study aims to assess the acute performance of the POLARx FIT™ CB system in AFCA. (2) Methods: Consecutive patients undergoing AF ablation with the POLARx FIT™ CB system in our center were included. The primary outcome was the rate of 31 mm balloon-size utilization, with secondary outcomes including acute pulmonary vein isolation (PVI) rate, periprocedural complications, and in-hospital AF recurrences. (3) Results: Twenty-four patients with a mean age of 59.5 years, predominantly male (87.5%), and exhibiting paroxysmal AF (91.7%) were enrolled. Procedural characteristics demonstrated a high acute success rate (100% PV isolation) with a favorable safety profile. Notably, the 31 mm CB configuration was utilized in 51% of applications, showcasing its adaptability in challenging anatomies. No major complications occurred, with two patients experiencing in-hospital self-limiting AF recurrences. (4) Conclusions: This study represents the first comprehensive assessment of the POLARx FIT™ CB system in AF ablation. While acknowledging the study’s limitations, this novel CB emerges as a promising tool, warranting further exploration in larger studies with extended follow-up periods

    Idiopathic Ventricular Tachycardia: Transcatheter Ablation or Antiarrhythmic Drugs?

    No full text
    Ventricular tachycardia or frequent premature ventricular contractions (PVCs) can occur in the absence of any detectable structural heart disease. In this clinical setting, these arrhythmias are termed idiopathic. Usually, they carry a benign prognosis and any potential ablative intervention is carried out if patients are highly symptomatic or, more importantly, if frequent ventricular arrhythmias can lead to ventricular dysfunction
    corecore