8 research outputs found

    Comparability of automated drusen volume measurements in age-related macular degeneration: a MACUSTAR study report

    Get PDF
    Drusen are hallmarks of early and intermediate age-related macular degeneration (AMD) but their quantification remains a challenge. We compared automated drusen volume measurements between different OCT devices. We included 380 eyes from 200 individuals with bilateral intermediate (iAMD, n = 126), early (eAMD, n = 25) or no AMD (n = 49) from the MACUSTAR study. We assessed OCT scans from Cirrus (200 × 200 macular cube, 6 × 6 mm; Zeiss Meditec, CA) and Spectralis (20° × 20°, 25 B-scans; 30° × 25°, 241 B-scans; Heidelberg Engineering, Germany) devices. Sensitivity and specificity for drusen detection and differences between modalities were assessed with intra-class correlation coefficients (ICCs) and mean difference in a 5 mm diameter fovea-centered circle. Specificity was > 90% in the three modalities. In eAMD, we observed highest sensitivity in the denser Spectralis scan (68.1). The two different Spectralis modalities showed a significantly higher agreement in quantifying drusen volume in iAMD (ICC 0.993 [0.991–0.994]) than the dense Spectralis with Cirrus scan (ICC 0.807 [0.757–0.847]). Formulae for drusen volume conversion in iAMD between the two devices are provided. Automated drusen volume measures are not interchangeable between devices and softwares and need to be interpreted with the used imaging devices and software in mind. Accounting for systematic difference between methods increases comparability and conversion formulae are provided. Less dense scans did not affect drusen volume measurements in iAMD but decreased sensitivity for medium drusen in eAMD. Trial registration: ClinicalTrials.gov NCT03349801. Registered on 22 November 2017

    Characteristics and Spatial Distribution of Structural Features in Age-Related Macular Degeneration: A MACUSTAR Study Report

    Get PDF
    Purpose: To report the prevalence and topographic distribution of structural characteristics in study participants with age-related macular degeneration (AMD) and controls in the cross-sectional study part of the MACUSTAR study (ClinicalTrials.gov Identifier: NCT03349801). Design: European, multicenter cohort study. Subjects: Overall, 301 eyes of 301 subjects with early (n = 34), intermediate (n = 168), and late AMD (n = 43), as well as eyes without any AMD features (n = 56). Methods: In study eyes with intermediate AMD (iAMD), the presence of structural AMD biomarkers, including pigmentary abnormalities (PAs), pigment epithelium detachment (PED), refractile deposits, reticular pseudodrusen (RPD), hyperreflective foci (HRF), incomplete/complete retinal pigment epithelium (RPE), and outer retinal atrophy (i/cRORA), and quiescent choroidal neovascularization (qCNV) was systematically determined in the prospectively acquired multimodal retinal imaging cross-sectional data set of MACUSTAR. Retinal layer thicknesses and the RPE drusen complex (RPEDC) volume were determined for the total study cohort in spectral-domain (SD) OCT imaging using a deep-learning–based algorithm. Main Outcome Measures: Prevalence and topographic distribution of structural iAMD features. Results: A total of 301 study eyes of 301 subjects with a mean (± standard deviation) age of 71.2 ± 7.20 years (63.1% women) were included. Besides large drusen, the most prevalent structural feature in iAMD study eyes were PA (57.1%), followed by HRF (51.8%) and RPD (22.0%). Pigment epithelium detachment lesions were observed in 4.8%, vitelliform lesions in 4.2%, refractile deposits in 3.0%, and qCNV in 2.4%. Direct precursor lesions for manifest retinal atrophy were detected in 10.7% (iRORA) and 4.2% (cRORA) in iAMD eyes. Overall, the highest RPEDC volume with a median of 98.92 × 10−4 mm³ was found in iAMD study eyes. Spatial analysis demonstrated a predominant distribution of RPD in the superior and temporal subfields at a foveal eccentricity of 1.5 to 2 mm, whereas HRF and large drusen had a distinct topographic distribution involving the foveal center. Conclusions: Detailed knowledge of the prevalence and distribution of structural iAMD biomarkers is vital to identify reliable outcome measure for disease progression. Longitudinal analyses are needed to evaluate their prognostic value for conversion to advanced disease stages. Financial Disclosure(s): Proprietary or commercial disclosure may be found after the references

    Comparability of automated drusen volume measurements in age-related macular degeneration: a MACUSTAR study report

    Get PDF
    Drusen are hallmarks of early and intermediate age-related macular degeneration (AMD) but their quantification remains a challenge. We compared automated drusen volume measurements between different OCT devices. We included 380 eyes from 200 individuals with bilateral intermediate (iAMD, n = 126), early (eAMD, n = 25) or no AMD (n = 49) from the MACUSTAR study. We assessed OCT scans from Cirrus (200 × 200 macular cube, 6 × 6 mm; Zeiss Meditec, CA) and Spectralis (20° × 20°, 25 B-scans; 30° × 25°, 241 B-scans; Heidelberg Engineering, Germany) devices. Sensitivity and specificity for drusen detection and differences between modalities were assessed with intra-class correlation coefficients (ICCs) and mean difference in a 5 mm diameter fovea-centered circle. Specificity was > 90% in the three modalities. In eAMD, we observed highest sensitivity in the denser Spectralis scan (68.1). The two different Spectralis modalities showed a significantly higher agreement in quantifying drusen volume in iAMD (ICC 0.993 [0.991–0.994]) than the dense Spectralis with Cirrus scan (ICC 0.807 [0.757–0.847]). Formulae for drusen volume conversion in iAMD between the two devices are provided. Automated drusen volume measures are not interchangeable between devices and softwares and need to be interpreted with the used imaging devices and software in mind. Accounting for systematic difference between methods increases comparability and conversion formulae are provided. Less dense scans did not affect drusen volume measurements in iAMD but decreased sensitivity for medium drusen in eAMD

    Frail inner limiting membrane maculopathy suggested to describe a new retinal Alport-like condition with two variants in three generations of females.

    No full text
    We report a three-generation family with isolated Alport-like retinal abnormalities in the absence of lenticonus, hearing loss, kidney disease, and detectable molecular genetic defects in known Alport-related genes. Clinical examination includes ocular biomicroscopy, fundus photography, optical coherence tomography, dipstick urinalysis, serum creatinine assessment, and molecular genetic analysis. The proband, her mother, and her maternal grandmother had normal best-corrected visual acuity and normal visual fields in both eyes. The macula presented a petaloid stair-case profile with scarce vessels in both eyes of the proband and a flat temporal macula lacking a foveal avascular zone in her mother and her grandmother. No family member had renal symptoms, unexplained subnormal hearing, or lenticonus. Sequencing and MLPA found no defect in COL4A3, COL4A4, and COL4A5. Common SNPs around the genes ± 1Mb showed no segregation. Furthermore, none of the variants shared between the affected individuals in genes from a gene panel of genes relevant for ophthalmopathy nor whole exome- and genome sequencing explained the phenotype. A new condition with two retinal Alport-like phenotypes was found. No abnormalities of the kidneys and lens were found, neither abnormalities of the type IV collagen genes related to Alport syndrome. Homology with retinal abnormalities seen in patients after surgical removal of the inner limiting membrane of the retina suggests that this is where the defect is located. We therefore suggest that the new retinal phenotypes and similar phenotypes can be described with the new definition "frail inner limiting membrane maculopathy.
    corecore