5,967 research outputs found

    Assessment of Regeneration Stocking Standards Used in Alberta: A Follow-Up

    Get PDF

    Aerobic training and angiogenesis activation in patients with stable chronic heart failure: a preliminary report.

    Get PDF
    The pathophysiology of chronic heart failure (CHF) involves multiple hystologic and molecular alterations. To determine the effects of physical training on circulating endothelial progenitor cells (EPCs), angiogenesis (angiogenin, angiopoietin-1 and -2, VEGF, Tie-2, SDF-1α) and inflammation (IL-6, CRP), we compared data obtained from 11 CHF pts before and after 3 months aerobic exercise training, to those from 10 non trained CHF pts (CHF-C group, age 64 + 2 years, NYHA 2). At the end of the study, EPCs count and AP-2 serum levels significantly increased in the CHF-TR group. These preliminary data suggest a significant effect of even a short program of physical training on angiogenic activation and endothelial dysfunction

    Evolution of Linear Absorption and Nonlinear Optical Properties in V-Shaped Ruthenium(II)-Based Chromophores

    Get PDF
    In this article, we describe a series of complexes with electron-rich cis-{Ru^(II)(NH_3)_4}^(2+) centers coordinated to two pyridyl ligands bearing N-methyl/arylpyridinium electron-acceptor groups. These V-shaped dipolar species are new, extended members of a class of chromophores first reported by us (Coe, B. J. et al. J. Am. Chem. Soc. 2005, 127, 4845−4859). They have been isolated as their PF_6− salts and characterized by using various techniques including ^1H NMR and electronic absorption spectroscopies and cyclic voltammetry. Reversible Ru^(III/II) waves show that the new complexes are potentially redox-switchable chromophores. Single crystal X-ray structures have been obtained for four complex salts; three of these crystallize noncentrosymmetrically, but with the individual molecular dipoles aligned largely antiparallel. Very large molecular first hyperpolarizabilities β have been determined by using hyper-Rayleigh scattering (HRS) with an 800 nm laser and also via Stark (electroabsorption) spectroscopic studies on the intense, visible d → π^* metal-to-ligand charge-transfer (MLCT) and π → π^* intraligand charge-transfer (ILCT) bands. The latter measurements afford total nonresonant β_0 responses as high as ca. 600 × 10^(−30) esu. These pseudo-C_(2v) chromophores show two substantial components of the β tensor, β_(zzz) and β_(zyy), although the relative significance of these varies with the physical method applied. According to HRS, β_(zzz) dominates in all cases, whereas the Stark analyses indicate that β_(zyy) is dominant in the shorter chromophores, but β_(zzz) and β_(zyy) are similar for the extended species. In contrast, finite field calculations predict that β_(zyy) is always the major component. Time-dependent density functional theory calculations predict increasing ILCT character for the nominally MLCT transitions and accompanying blue-shifts of the visible absorptions, as the ligand π-systems are extended. Such unusual behavior has also been observed with related 1D complexes (Coe, B. J. et al. J. Am. Chem. Soc. 2004, 126, 3880−3891)

    Prevalence of pain in the departments of surgery and oncohematology of a paediatric hospital that has joined the project "Towards pain free hospital"

    Get PDF
    Background. Among hospitalized adults and children pain is undertreated. This study wants to assess the effectiveness of pain therapy in two departments of a large children's hospital. Materials and Methods. During a single day work three committees, administering a questionnaire to patients or parents, have evaluated the adherence to international recommendations (JCI and WHO) in the management of analgesic therapy. Patient demographics, prevalence and intensity (moderate and/or severe) of pain (during hospitalization, 24 hours before and at the time of the interview), analgesia (type, route, duration and frequency of administration) and Pain Management Index (=analgesic score-pain score) were recorded. Results. 75 patients participated in the study (age: 2 months up to 24 years, mean 7.8 ± 6). During hospitalization 43 children (57%) had no pain while 32 (43%) have experienced pain. 22 children (29 %) had pain 24 hours before and 12 (16%) at the time of the interview. The average value of the PMI was -0.8±1.3 with a minimum of -3 and a maximum of +2: 60% (19) of the children had a PMI less than 0 (undertreated pain) while 40% (13) had a value=or > 0. Out of 32 patients who needed an analgesic therapy 14 (44%) received an around-the-clock dosing, 8 (25%) an intermittent therapy and 10 (31%) no treatment.17 (77 %) were the single drug therapy and 5 (23%) the multimodal ones. Conclusion. The prevalence of pain in the two departments is high. The main cause is that knowledge is not still well translated into clinical practice

    Measurement of the hadronic photon structure function F_{2}^{γ} at LEP2

    Get PDF
    The hadronic structure function of the photon F_{2}^{γ} (x, Q²) is measured as a function of Bjorken x and of the photon virtuality Q² using deep-inelastic scattering data taken by the OPAL detector at LEP at e⁺e⁻ centre-of-mass energies from 183 to 209 GeV. Previous OPAL measurements of the x dependence of F_{2}^{γ} are extended to an average Q² of 〈Q²〉=780 GeV² using data in the kinematic range 0.15<x<0.98. The Q² evolution of F_{2}^{γ} is studied for 12.1<〈Q²〉<780 GeV² using three ranges of x. As predicted by QCD, the data show positive scaling violations in F_{2}^{γ} with F_{2}^{γ} (Q²)/α = (0.08±0.02⁺⁰·⁰⁵_₀.₀₃) + (0.13±0.01⁺⁰·⁰¹_₀.₀₁) lnQ², where Q² is in GeV², for the central x region 0.10–0.60. Several parameterisations of F_{2}^{γ} are in qualitative agreement with the measurements whereas the quark-parton model prediction fails to describe the data

    Measurement of triple gauge boson couplings from W⁺W⁻ production at LEP energies up to 189 GeV

    Get PDF
    A measurement of triple gauge boson couplings is presented, based on W-pair data recorded by the OPAL detector at LEP during 1998 at a centre-of-mass energy of 189 GeV with an integrated luminosity of 183 pb⁻¹. After combining with our previous measurements at centre-of-mass energies of 161–183 GeV we obtain κ = 0.97_{-0.16}^{+0.20}, g_{1}^{z} = 0.991_{-0.057}^{+0.060} and λ = -0.110_{-0.055}^{+0.058}, where the errors include both statistical and systematic uncertainties and each coupling is determined by setting the other two couplings to their Standard Model values. These results are consistent with the Standard Model expectations

    Low and decreasing vaccine effectiveness against influenza A(H3) in 2011/12 among vaccination target groups in Europe: results from the I-MOVE multicentre case-control study

    Get PDF
    Within the Influenza Monitoring Vaccine Effectiveness in Europe (I-MOVE) project we conducted a multicentre case–control study in eight European Union (EU) Member States to estimate the 2011/12 influenza vaccine effectiveness against medically attended influenza-like illness (ILI) laboratory-confirmed as influenza A(H3) among the vaccination target groups. Practitioners systematically selected ILI / acute respiratory infection patients to swab within seven days of symptom onset. We restricted the study population to those meeting the EU ILI case definition and compared influenza A(H3) positive to influenza laboratory-negative patients. We used logistic regression with study site as fixed effect and calculated adjusted influenza vaccine effectiveness (IVE), controlling for potential confounders (age group, sex, month of symptom onset, chronic diseases and related hospitalisations, number of practitioner visits in the previous year). Adjusted IVE was 25% (95% confidence intervals (CI): -6 to 47) among all ages (n=1,014), 63% (95% CI: 26 to 82) in adults aged between 15 and 59 years and 15% (95% CI: -33 to 46) among those aged 60 years and above. Adjusted IVE was 38% (95%CI: -8 to 65) in the early influenza season (up to week 6 of 2012) and -1% (95% CI: -60 to 37) in the late phase. The results suggested a low adjusted IVE in 2011/12. The lower IVE in the late season could be due to virus changes through the season or waning immunity. Virological surveillance should be enhanced to quantify change over time and understand its relation with duration of immunological protection. Seasonal influenza vaccines should be improved to achieve acceptable levels of protection.ECD

    Measurement of the charm structure function F_{2,c)^{γ} of the photon at LEP

    Get PDF
    The production of charm quarks is studied in deep-inelastic electron–photon scattering using data recorded by the OPAL detector at LEP at nominal e⁺e⁻ centre-of-mass energies from 183 to 209 GeV. The charm quarks have been identified by full reconstruction of charged D* mesons using their decays into D⁰π with the D⁰ observed in two decay modes with charged particle final states, Kπ and Kπππ. The cross-section σ^{D*} for production of charged D* in the reaction e⁺e⁻→e⁺e⁻D*Χ is measured in a restricted kinematical region using two bins in Bjorken x, 0.00140.1 the perturbative QCD calculation at next-to-leading order agrees perfectly with the measured cross-section. For x<0.1 the measured cross-section is 43.8±14.3±6.3±2.8 pb with a next-to-leading order prediction of 17.0⁺²·⁹_₂.₃ pb
    corecore