854 research outputs found

    Combination of intact, middle-up and bottom-up levels to characterize 7 therapeutic monoclonal antibodies by capillary electrophoresis – Mass spectrometry

    Get PDF
    Significant growth of biopharmaceuticals requires powerful analytical methods to better understand their structure by establishing a complete characterization. To this end, a combination of bottom-up, middle-up and intact molecule levels with a capillary electrophoresis-mass spectrometry coupling has been performed to have a comprehensive picture of monoclonal antibodies. In this study, 7 worldwide health authorities approved mAbs have been analyzed to get information about their charge heterogeneity, the identification of post translational modifications (PTMs), their location and relative quantitation. Intact mAbs isoforms have been partially separated in less than 12 minutes and enabled to have a global illustration of mAbs heterogeneity and high masses PTMs characterization notably major N-glycosylation forms. Particularly, 2X-glycosylated and 1X-glycosylated forms have been partially separated. To deepen characterize PTMs carried by the backbone structure, advanced investigations at a middle-up level have been performed. Limited IdeS proteolysis allowed to study independently Fc/2 and F(ab)’2 fragments. Following the same separation conditions, isoforms of these fragments have been separated and data interpretation allowed to disclose additional PTMs as K-clip, oxidations or deamidations. A second intermediate level has been examined by adding a reduction step to establish a more precise assessment of PTMs and isoforms from the F(ab)’2 fragment. This reduction step released the light chains from the Fd fragment to get only 25 kDa fragments to analyze. CE-ESI-MS coupling allowed to get more information particularly about low masses PTMs. The precise location and relative quantitation of each PTM has been investigated at the peptidic level induced by a tryptic digestion of the studied mAbs. The concordance of the results shows the efficiency of the CE-ESI-MS coupling to characterize mAbs and highlight the need of the multi-level combination to get a comprehensive characterization of biotherapeutics

    Top-down analysis of immunoglobulin G isotypes 1 and 2 with electron transfer dissociation on a high-field Orbitrap mass spectrometer

    Get PDF
    The increasing importance of immunoglobulins G (IgGs) as biotherapeutics calls for improved structural characterization methods designed for these large (~ 150 kDa) macromolecules. Analysis workflows have to be rapid, robust, and require minimal sample preparation. In a previous work we showed the potential of Orbitrap Fourier transform mass spectrometry (FTMS) combined with electron transfer dissociation (ETD) for the top-down investigation of an intact IgG1, resulting in ~ 30% sequence coverage. Here, we describe a top-down analysis of two IgGs1 (adalimumab and trastuzumab) and one IgG2 (panitumumab) performed with ETD on a mass spectrometer equipped with a high-field Orbitrap mass analyzer. For the IgGs1, sequence coverage comparable to the previous results was achieved in a two-fold reduced number of summed transients, which corresponds, taken together with the significantly increased spectra acquisition rate, to ~ six-fold improvement in analysis time. Furthermore, we studied the influence of ion-ion interaction times on ETD product ions for IgGs1, and the differences in fragmentation behavior between IgGs1 and IgG2, which present structural differences. Overall, these results reinforce the hypothesis that gas phase dissociation using both energy threshold-based and radical-driven ion activations is directed to specific regions of the polypeptide chains mostly by the location of disulfide bonds

    Fluctuating diamagnetism in underdoped high temperature superconductors

    Full text link
    The fluctuation induced diamagnetism of underdoped high temperature superconductors is studied in the framework of the Lawrence-Doniach model. By taking into account the fluctuations of the phase of the order parameter only, the latter reduces to a layered XY-model describing a liquid of vortices which can be either thermally excited or induced by the external magnetic field. The diamagnetic response is given by a current-current correlation function which is evaluated using the Coulomb gas analogy. Our results are then applied to recent measurements of fluctuation diamagnetism in underdoped YBCO. They allow to understand both the observed anomalous temperature dependence of the zero-field susceptibility and the two distinct regimes appearing in the magnetic field dependence of the magnetization.Comment: 12 pages, 4 figures included, accepted for publication in PR

    Intact monoclonal antibodies separation and analysis by sheathless capillary electrophoresis-mass spectrometry

    Get PDF
    Capillary electrophoresis mass spectrometry coupling (CE-MS) is a growing technique in biopharmaceutics characterization. Assessment of monoclonal antibodies (mAbs) is well known at middle-up and bottom-up levels to obtain information about the sequence, post-translational modifications (PTMs) and degradation products. Intact protein analysis is an actual challenge to be closer to the real protein structure. At this level, actual techniques are time consuming or cumbersome processes. In this work, a 20 minutes separation method has been developed to optimize characterization of intact mAbs. Thus, separation have been done on a positively-charged coated capillary (PEI) with optimized volatile background electrolyte (BGE) and sample buffer (SB). A sheathless interface allowed to hyphenate CE to a quadrupole-time-of-flight mass spectrometer (Q-TOF) which parameters has been tuned to improve the high masses detection and identification of intact mAbs. Three world-wide health authorities approved mAbs have been used to set up a rapid and ease of use method. Intact trastuzumab, rituximab and palivizumab isoforms have been partially separated with this method in less than 20 minutes under denaturing conditions. For each mAb, 2X-glycosylated and 1X-glycosylated structures have been identified and separated. Concerning basic and acidic variants potential Iso-Asp modification and Asn deamidation have been observed. Accurate mass determination for high-mass molecular species remains a challenge, but the progress in intact mAbs separation appears very promising for biopharmaceutics characterization

    Structural characterization of antibody drug conjugate by a combination of intact, middle-up and bottom-up techniques using sheathless capillary electrophoresis – Tandem mass spectrometry as nanoESI infusion platform and separation method

    Get PDF
    Antibody-drug conjugates (ADCs) represent a fast growing class of biotherapeutic products. Their production leads to a distribution of species exhibiting different number of conjugated drugs overlaying the inherent com-plexity resulting from the monoclonal antibody format, such as glycoforms. ADCs require an additional level of characterization compared to first generation of biotherapeutics obtained through multiple analytical tech-niques for complete structure assessment. We report the development of complementary approaches imple-menting sheathless capillary electrophoresis-mass spectrometry (sheathless CE-MS) to characterize the differ-ent aspects defining the structure of brentuximab vedotin. Native MS using sheathless CE-MS instrument as a nanoESI infusion platform enabled accurate mass measurements and estimation of the average drug to anti-body ratio alongside to drug load distribution. Middle-up analysis performed after limited IdeS proteolysis allowed to study independently the light chain, Fab and F(ab’)2 subunits incorporating 1, 0 to 4 and 0 to 8 pay-loads respectively. Finally, a CZE-ESI-MS/MS methodology was developed in order to be compatible with hy-drophobic drug composing ADCs. From a single injection, complete sequence coverage could be achieved. Using the same dataset, glycosylation and drug-loaded peptides could be simultaneously identified revealing robust information regarding their respective localization and abundance. Drug-loaded peptide fragmentation mass spectra study demonstrated drug specific fragments reinforcing identification confidence, undescribed so far. Results reveal the method ability to characterize ADCs primary structure in a comprehensive manner while reducing tremendously the number of experiments required. Data generated showed that sheathless CZE-ESI-MS/MS characteristics position the methodology developed as a relevant alternative for comprehensive multi-level characterization of these complex biomolecule

    Phenoloxidase activity acts as a mosquito innate immune response against infection with semliki forest virus

    Get PDF
    Several components of the mosquito immune system including the RNA interference (RNAi), JAK/STAT, Toll and IMD pathways have previously been implicated in controlling arbovirus infections. In contrast, the role of the phenoloxidase (PO) cascade in mosquito antiviral immunity is unknown. Here we show that conditioned medium from the Aedes albopictus-derived U4.4 cell line contains a functional PO cascade, which is activated by the bacterium Escherichia coli and the arbovirus Semliki Forest virus (SFV) (Togaviridae; Alphavirus). Production of recombinant SFV expressing the PO cascade inhibitor Egf1.0 blocked PO activity in U4.4 cell- conditioned medium, which resulted in enhanced spread of SFV. Infection of adult female Aedes aegypti by feeding mosquitoes a bloodmeal containing Egf1.0-expressing SFV increased virus replication and mosquito mortality. Collectively, these results suggest the PO cascade of mosquitoes plays an important role in immune defence against arboviruses

    Rapid and multi-level characterization of trastuzumab using sheathless capillary electrophoresis-tandem mass spectrometry

    Get PDF
    Monoclonal antibodies (mAbs) are highly complex proteins that display a wide range of microheterogeneity that requires multiple analytical methods for full structure assessment and quality control. As a consequence, the characterization of mAbs on different levels is particularly product - and time - consuming. This work presents the characterization of trastuzumab sequence using sheathless capillary electrophoresis (referred as CESI) – tandem mass spectrometry (CESIMS/MS). Using this bottom-up proteomic-like approach, CESI-MS/MS provided 100% sequence coverage for both heavy and light chain via peptide fragment fingerprinting (PFF) identification. The result was accomplished in a single shot, corresponding to the analysis of 100 fmoles of digest. The same analysis also enabled precise characterization of the post-translational hot spots of trastuzumab, used as a representative widely marketed therapeutic mAb, including the structural confirmation of the five major N-glycoforms

    Monoclonal antibodies biosimilarity assessment using transient isotachophoresis capillary zone electrophoresis-tandem mass spectrometry

    Get PDF
    Out of all categories, monoclonal antibody (mAb) therapeutics attract the most interest due to their strong therapeutic potency and specificity. Six of the ten top-selling drugs are antibody-based therapeutics that will lose patent protection soon. The European Medicines Agency has pioneered the regulatory framework for approval of biosimilar products and approved the first biosimilar antibodies by the end of 2013. As highly complex glycoproteins with a wide range of micro-variants, mAbs require extensive characterization through multiple analytical methods for structure assessment rendering manufacturing control and biosimilarity studies particularly product and time-consuming. Here, capillary zone electrophoresis coupled to mass spectrometry by a sheathless interface (CESI-MS) was used to characterize marketed reference mAbs and their respective biosimilar candidate simultaneously over different facets of their primary structure. CESI-MS/MS data were compared between approved mAbs and their biosimilar candidates to prove/disconfirm biosimilarity regarding recent regulation directives. Using only a single sample injection of 200 fmol, CESI-MS/MS data enabled 100% amino acids (AA) sequence characterization, which allows a difference of even one AA between two samples to be distinguished precisely. Simultaneously glycoforms were characterized regarding their structures and position through fragmentation spectra and glycoforms semiquantitative analysis was established, showing the capacity of the developed methodology to detect up to 16 different glycans. Other posttranslational modifications hotspots were characterized while their relative occurrence levels were estimated and compared to biosimilars. These results proved the value of using CESI-MS because the separation selectivity and ionization efficiency provided by the system allowed substantial improvement in the characterization workflow robustness and accuracy. Biosimilarity assessment could be performed routinely with a single injection of each candidate enabling improvements in the biosimilar development pipeline

    Characterization by liquid chromatography combined with mass spectrometry of monoclonal anti-IGF-1 receptor antibodies produced in CHO and NS0 cells

    Get PDF
    7H2HM is a new humanized recombinant monoclonal antibody (MAb) directed against insulin-like growth factor-1 receptor and produced in CHO cells. Homogeneity of intact antibody, reduced light and heavy chains, Fab and Fc fragments were investigated by analytical methods based on mass (SDS-PAGE, SEC), charge (IEF, C-IEX) and hydrophobicity differences (RP-HPLC, HIC) and compared side-by-side with A2CHM, produced in NS0 cells. Primary structures and disulfide bridge pairing were analyzed by microsequencing (Edman degradation), mass spectrometry (MALDI–TOF, ES–TOF) and peptide mapping after enzymatic digestion (Trypsin, endoprotease Lys-C, papain). The light chains demonstrated the expected sequences. The heavy chains yielded post-translational modifications previously reported for other recombinant humanized or human IgG1 such as N-terminal pyroglutamic acid, C-terminal lysine clipping and N-glycosylation for asparagine 297. More surprisingly, two-thirds of the 7H2HM heavy chains were shown to contain an additional 24-amino-acid sequence, corresponding to the translation of an intron located between the variable and the constant domains. Taken together these data suggest that 7H2HM is a mixture of three families of antibodies corresponding (i) to the expected structure (17%; 149 297 Da; 1330 amino acids), (ii) a variant with a translated intron in one heavy chains (33%; 152 878 Da; 1354 amino acids) and (iii) a variant with translated introns in two heavy chains (50%; 154 459 Da; 1378 amino acids), respectively. RP-HPLC is not a commonly used chromatographic method to assess purity of monoclonal antibodies but unlike to SEC and SDS-PAGE, was able to show and to quantify the family of structures present in 7H2HM, which were also identified by peptide mapping, mass spectrometry and microsequencing
    • …
    corecore