1,016 research outputs found

    Performance of magnetic resonance imaging-based prostate cancer risk calculators and decision strategies in two large European medical centres

    Get PDF
    Objectives: To compare the performance of currently available biopsy decision support tools incorporating magnetic resonance imaging (MRI) findings in predicting clinically significant prostate cancer (csPCa). Patients and Methods: We retrospectively included men who underwent prostate MRI and subsequent targeted and/or systematic prostate biopsies in two large European centres. Available decision support tools were identified by a PubMed search. Performance was assessed by calibration, discrimination, decision curve analysis (DCA) and numbers of biopsies avoided vs csPCa cases missed, before and after recalibration, at risk thresholds of 5%–20%. Results: A total of 940 men were included, 507 (54%) had csPCa. The median (interquartile range) age, prostate-specific antigen (PSA) level, and PSA density (PSAD) were 68 (63–72) years, 9 (7–15) ng/mL, and 0.20 (0.13–0.32) ng/mL2, respectively. In all, 18 multivariable risk calculators (MRI-RCs) and dichotomous biopsy decision strategies based on MRI findings and PSAD thresholds were assessed. The Van Leeuwen model and the Rotterdam Prostate Cancer Risk Calculator (RPCRC) had the best discriminative ability (area under the receiver operating characteristic curve 0.86) of the MRI-RCs that could be assessed in the whole cohort. DCA showed the highest clinical utility for the Van Leeuwen model, followed by the RPCRC. At the 10% threshold the Van Leeuwen model would avoid 22% of biopsies, missing 1.8% of csPCa, whilst the RPCRC would avoid 20% of biopsies, missing 2.6% of csPCas. These multivariable models outperformed all dichotomous decision strategies based only on MRI-findings and PSAD. Conclusions: Even in this high-risk cohort, biopsy decision support tools would avoid many prostate biopsies, whilst missing very few csPCa cases. The Van Leeuwen model had the highest clinical utility, followed by the RPCRC. These multivariable MRI-RCs outperformed and should be favoured over decision strategies based only on MRI and PSAD.</p

    Vestibular disease in dogs: association between neurological examination, MRI lesion localisation and outcome.

    Get PDF
    OBJECTIVES To determine whether the neurological examination correctly distinguishes between central and peripheral vestibular lesions in dogs. MATERIALS AND METHODS Retrospective study on dogs with vestibular disease presenting to two referral clinics in Germany. RESULTS Ninety-three dogs were included; neurological examination suggested central vestibular disease in 62 and a peripheral lesion in 31. MRI diagnosis was central vestibular disease in 68 dogs and peripheral in 25. Of the 62 dogs with a lesion localisation diagnosed as central vestibular by neurological exam, 61 were correctly identified (98.4%). Twenty-four of the 31 dogs diagnosed with a peripheral lesion by neurological exam had a consistent lesion on MRI (77.4%). CLINICAL SIGNIFICANCE The neurological examination is efficient at identifying lesions in the central vestibular system but less so for peripheral lesions. Therefore it is prudent to recommend imaging in dogs that show signs of peripheral vestibular syndrome but do not rapidly respond to treatment

    Diamond (111) surface reconstruction and epitaxial graphene interface

    Get PDF
    The evolution of the diamond (111) surface as it undergoes reconstruction and subsequent graphene formation is investigated with angle-resolved photoemission spectroscopy, low energy electron diffraction, and complementary density functional theory calculations. The process is examined starting at the C(111)-(2x1) surface reconstruction that occurs following detachment of the surface adatoms at 920 {\deg}C, and continues through to the liberation of the reconstructed surface atoms into a free-standing monolayer of epitaxial graphene at temperatures above 1000 {\deg}C. Our results show that the C(111)-(2x1) surface is metallic as it has electronic states that intersect the Fermi-level. This is in strong agreement with a symmetrically {\pi}-bonded chain model and should contribute to resolving the controversies that exist in the literature surrounding the electronic nature of this surface. The graphene formed at higher temperatures exists above a newly formed C(111)-(2\times1) surface and appears to have little substrate interaction as the Dirac-point is observed at the Fermi-level. Finally, we demonstrate that it is possible to hydrogen terminate the underlying diamond surface by means of plasma processing without removing the graphene layer, forming a graphene-semiconductor interface. This could have particular relevance for doping the graphene formed on the diamond (111)surface via tuneable substrate interactions as a result of changing the terminating species at the diamond-graphene interface by plasma processing.Comment: 10 pages, 4 figure

    Quantification of multiple steroid hormones in serum and human breast cancer tissue by liquid chromatography-tandem mass spectrometry analysis

    Get PDF
    IntroductionSystemic and local steroid hormone levels may function as novel prognostic and predictive biomarkers in breast cancer patients. We aimed at developing a novel liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the simultaneous measurement of multiple, biologically pivotal steroid hormones in human serum and breast cancer tissue.MethodsThe quantitative method consisted of liquid-liquid extraction, Sephadex LH-20 chromatography for tissue extracts, and analysis of steroid hormones by liquid-chromatography-tandem mass spectrometry. We analyzed serum and tissue steroid hormone levels in 16 and 40 breast cancer patients, respectively, and assessed their correlations with clinical parameters.ResultsThe method included quantification of nine steroid hormones in serum [including cortisol, cortisone, corticosterone, estrone (E1), 17β-estradiol (E2), 17α-hydroxyprogesterone, androstenedione (A4), testosterone and progesterone) and six (including cortisone, corticosterone, E1, E2, A4, and testosterone) in cancer tissue. The lower limits of quantification were between 0.003–10 ng/ml for serum (250 µl) and 0.038–125 pg/mg for tissue (20 mg), respectively. Accuracy was between 98%-126%, intra-assay coefficient of variations (CV) was below 15%, and inter-assay CV were below 11%. The analytical recoveries for tissue were between 76%-110%. Tissue levels of E1 were positively correlated with tissue E2 levels (p&lt;0.001), and with serum levels of E1, E2 and A4 (p&lt;0.01). Tissue E2 levels were positively associated with serum E1 levels (p=0.02), but not with serum E2 levels (p=0.12). The levels of tissue E2 and ratios of E1 to A4 levels (an index for aromatase activity) were significantly higher in patients with larger tumors (p=0.03 and p=0.02, respectively).ConclusionsThe method was convenient and suitable for a specific and accurate profiling of clinically important steroid hormones in serum. However, the sensitivity of the profile method in steroid analysis in tissue samples is limited, but it can be used for the analysis of steroids in breast cancer tissues if the size of the sample or its steroid content is sufficient

    International Veterinary Epilepsy Task Force recommendations for a veterinary epilepsy-specific MRI protocol

    Get PDF
    Epilepsy is one of the most common chronic neurological diseases in veterinary practice. Magnetic resonance imaging (MRI) is regarded as an important diagnostic test to reach the diagnosis of idiopathic epilepsy. However, given that the diagnosis requires the exclusion of other differentials for seizures, the parameters for MRI examination should allow the detection of subtle lesions which may not be obvious with existing techniques. In addition, there are several differentials for idiopathic epilepsy in humans, for example some focal cortical dysplasias, which may only apparent with special sequences, imaging planes and/or particular techniques used in performing the MRI scan. As a result, there is a need to standardize MRI examination in veterinary patients with techniques that reliably diagnose subtle lesions, identify post-seizure changes, and which will allow for future identification of underlying causes of seizures not yet apparent in the veterinary literature. There is a need for a standardized veterinary epilepsy-specific MRI protocol which will facilitate more detailed examination of areas susceptible to generating and perpetuating seizures, is cost efficient, simple to perform and can be adapted for both low and high field scanners. Standardisation of imaging will improve clinical communication and uniformity of case definition between research studies. A 6–7 sequence epilepsy-specific MRI protocol for veterinary patients is proposed and further advanced MR and functional imaging is reviewed

    Multiplicity dependence of jet-like two-particle correlations in p-Pb collisions at sNN\sqrt{s_{NN}} = 5.02 TeV

    Full text link
    Two-particle angular correlations between unidentified charged trigger and associated particles are measured by the ALICE detector in p-Pb collisions at a nucleon-nucleon centre-of-mass energy of 5.02 TeV. The transverse-momentum range 0.7 <pT,assoc<pT,trig< < p_{\rm{T}, assoc} < p_{\rm{T}, trig} < 5.0 GeV/cc is examined, to include correlations induced by jets originating from low momen\-tum-transfer scatterings (minijets). The correlations expressed as associated yield per trigger particle are obtained in the pseudorapidity range η<0.9|\eta|<0.9. The near-side long-range pseudorapidity correlations observed in high-multiplicity p-Pb collisions are subtracted from both near-side short-range and away-side correlations in order to remove the non-jet-like components. The yields in the jet-like peaks are found to be invariant with event multiplicity with the exception of events with low multiplicity. This invariance is consistent with the particles being produced via the incoherent fragmentation of multiple parton--parton scatterings, while the yield related to the previously observed ridge structures is not jet-related. The number of uncorrelated sources of particle production is found to increase linearly with multiplicity, suggesting no saturation of the number of multi-parton interactions even in the highest multiplicity p-Pb collisions. Further, the number scales in the intermediate multiplicity region with the number of binary nucleon-nucleon collisions estimated with a Glauber Monte-Carlo simulation.Comment: 23 pages, 6 captioned figures, 1 table, authors from page 17, published version, figures at http://aliceinfo.cern.ch/ArtSubmission/node/161
    corecore