41 research outputs found
Numerical Simulation of Nano Scanning in Intermittent-Contact Mode AFM under Q control
We investigate nano scanning in tapping mode atomic force microscopy (AFM)
under quality (Q) control via numerical simulations performed in SIMULINK. We
focus on the simulation of whole scan process rather than the simulation of
cantilever dynamics and the force interactions between the probe tip and the
surface alone, as in most of the earlier numerical studies. This enables us to
quantify the scan performance under Q control for different scan settings.
Using the numerical simulations, we first investigate the effect of elastic
modulus of sample (relative to the substrate surface) and probe stiffness on
the scan results. Our numerical simulations show that scanning in attractive
regime using soft cantilevers with high Qeff results in a better image quality.
We, then demonstrate the trade-off in setting the effective Q factor (Qeff) of
the probe in Q control: low values of Qeff cause an increase in tapping forces
while higher ones limit the maximum achievable scan speed due to the slow
response of the cantilever to the rapid changes in surface profile. Finally, we
show that it is possible to achieve higher scan speeds without causing an
increase in the tapping forces using adaptive Q control (AQC), in which the Q
factor of the probe is changed instantaneously depending on the magnitude of
the error signal in oscillation amplitude. The scan performance of AQC is
quantitatively compared to that of standard Q control using iso-error curves
obtained from numerical simulations first and then the results are validated
through scan experiments performed using a physical set-up
Evaluation of a new virtual-reality training simulator for hysteroscopy
BACKGROUND: To determine realism and training capacity of HystSim, a new virtual-reality simulator for the training of hysteroscopic interventions. METHODS: Sixty-two gynaecological surgeons with various levels of expertise were interviewed at the 13(th) Practical Course in Gynaecologic Endoscopy in Davos, Switzerland. All participants received a 20-min hands-on training on the simulator and filled out a four-page questionnaire. Twenty-three questions with respect to the realism of the simulation and the training capacity were answered on a seven-point Likert scale along with 11 agree-disagree statements concerning the HystSim training in general. RESULTS: Twenty-six participants had performed more than 50 hysteroscopies ("experts") and 36 equal to or fewer than 50 ("novices"). Four of 60 (6.6%) responding participants judged the overall impression as "7 - absolutely realistic", 40 (66.6%) as "6 - realistic", and 16 (26.6%) as "5 - somewhat realistic". Novices (6.48; 95% confidence interval [CI] 6.28-6.7) rated the overall training capacity significantly higher than experts (6.08; 95% CI 5.85-6.3), however, high-grade acceptance was found in both groups. In response to the statements, 95.2% believe that HystSim allows procedural training of diagnostic and therapeutic hysteroscopy, and 85.5% suggest that HystSim training should be offered to all novices before performing surgery on real patients. CONCLUSION: Face validity has been established for a new hysteroscopic surgery simulator. Potential trainees and trainers assess it to be a realistic and useful tool for the training of hysteroscopy. Further systematic validation studies are needed to clarify how this system can be optimally integrated into the gynaecological curriculum
Sensory Communication
Contains table of contents for Section 2, an introduction and reports on twelve research projects.National Institutes of Health Grant R01 DC00117National Institutes of Health Grant R01 DC02032National Institutes of Health/National Institute of Deafness and Other Communication Disorders Grant 2 R01 DC00126National Institutes of Health Grant 2 R01 DC00270National Institutes of Health Contract N01 DC-5-2107National Institutes of Health Grant 2 R01 DC00100U.S. Navy - Office of Naval Research Grant N61339-96-K-0002U.S. Navy - Office of Naval Research Grant N61339-96-K-0003U.S. Navy - Office of Naval Research Grant N00014-97-1-0635U.S. Navy - Office of Naval Research Grant N00014-97-1-0655U.S. Navy - Office of Naval Research Subcontract 40167U.S. Navy - Office of Naval Research Grant N00014-96-1-0379U.S. Air Force - Office of Scientific Research Grant F49620-96-1-0202National Institutes of Health Grant RO1 NS33778Massachusetts General Hospital, Center for Innovative Minimally Invasive Therapy Research Fellowship Gran
Sensory Communication
Contains table of contents for Section 2, an introduction and reports on fourteen research projects.National Institutes of Health Grant RO1 DC00117National Institutes of Health Grant RO1 DC02032National Institutes of Health/National Institute on Deafness and Other Communication Disorders Grant R01 DC00126National Institutes of Health Grant R01 DC00270National Institutes of Health Contract N01 DC52107U.S. Navy - Office of Naval Research/Naval Air Warfare Center Contract N61339-95-K-0014U.S. Navy - Office of Naval Research/Naval Air Warfare Center Contract N61339-96-K-0003U.S. Navy - Office of Naval Research Grant N00014-96-1-0379U.S. Air Force - Office of Scientific Research Grant F49620-95-1-0176U.S. Air Force - Office of Scientific Research Grant F49620-96-1-0202U.S. Navy - Office of Naval Research Subcontract 40167U.S. Navy - Office of Naval Research/Naval Air Warfare Center Contract N61339-96-K-0002National Institutes of Health Grant R01-NS33778U.S. Navy - Office of Naval Research Grant N00014-92-J-184