268 research outputs found

    Influence of anticardiolipin and anti-β2 glycoprotein I antibody cutoff values on antiphospholipid syndrome classification

    Get PDF
    Background: Anticardiolipin (aCL) and anti-beta 2 glycoprotein I (a beta 2GPI) immunoglobulin (Ig) G/IgM antibodies are 2 of the 3 laboratory criteria for classification of antiphospholipid syndrome (APS). The threshold for clinically relevant levels of antiphospholipid antibodies (aPL) for the diagnosis of APS remains a matter of debate. The aim of this study was to evaluate the variation in cutoffs as determined in different clinical laboratories based on the results of a questionnaire as well as to determine the optimal method for cutoff establishment based on a clinical approach.Methods: The study included samples from 114 patients with thrombotic APS, 138 patients with non-APS thrombosis, 138 patients with autoimmune disease, and 183 healthy controls. aCL and a beta 2GPI IgG/IgM antibodies were measured at 1 laboratory using 4 commercial assays. Assay-specific cutoff values for aPL were obtained by determining 95th and 99th percentiles of 120 compared to 200 normal controls by different statistical methods.Results: Normal reference value data showed a nonparametric distribution. Higher cutoff values were found when calculated as 99th rather than 95th percentiles. These values also showed a stronger association with thrombosis. The use of 99th percentile cutoffs reduced the chance of false positivity but at the same time reduced sensitivity. The decrease in sensitivity was higher than the gain in specificity when 99th percentiles were calculated by methods wherein no outliers were eliminated.Conclusions: We present cutoff values for aPL determined by different statistical methods. The 99th percentile cutoff value seemed more specific. However, our findings indicate the need for standardized statistical criteria to calculate 99th percentile cutoff reference values.Background: Anticardiolipin (aCL) and anti-beta 2 glycoprotein I (a beta 2GPI) immunoglobulin (Ig) G/IgM antibodies are 2 of the 3 laboratory criteria for classification of antiphospholipid syndrome (APS). The threshold for clinically relevant levels of antiphospholipid antibodies (aPL) for the diagnosis of APS remains a matter of debate. The aim of this study was to evaluate the variation in cutoffs as determined in different clinical laboratories based on the results of a questionnaire as well as to determine the optimal method for cutoff establishment based on a clinical approach.Methods: The study included samples from 114 patients with thrombotic APS, 138 patients with non-APS thrombosis, 138 patients with autoimmune disease, and 183 healthy controls. aCL and a beta 2GPI IgG/IgM antibodies were measured at 1 laboratory using 4 commercial assays. Assay-specific cutoff values for aPL were obtained by determining 95th and 99th percentiles of 120 compared to 200 normal controls by different statistical methods.Results: Normal reference value data showed a nonparametric distribution. Higher cutoff values were found when calculated as 99th rather than 95th percentiles. These values also showed a stronger association with thrombosis. The use of 99th percentile cutoffs reduced the chance of false positivity but at the same time reduced sensitivity. The decrease in sensitivity was higher than the gain in specificity when 99th percentiles were calculated by methods wherein no outliers were eliminated.Conclusions: We present cutoff values for aPL determined by different statistical methods. The 99th percentile cutoff value seemed more specific. However, our findings indicate the need for standardized statistical criteria to calculate 99th percentile cutoff reference values.A

    Semi-automated thrombin dynamics applying the ST Genesia thrombin generation assay

    Get PDF
    BackgroundThe haemostatic balance is an equilibrium of pro- and anticoagulant factors that work synergistically to prevent bleeding and thrombosis. As thrombin is the central enzyme in the coagulation pathway, it is desirable to measure thrombin generation (TG) in order to detect possible bleeding or thrombotic phenotypes, as well as to investigate the capacity of drugs affecting the formation of thrombin. By investigating the underlying processes of TG (i.e., prothrombin conversion and inactivation), additional information is collected about the dynamics of thrombin formation.ObjectivesTo obtain reference values for thrombin dynamics (TD) analysis in 112 healthy donors using an automated system for TG.MethodsTG was measured on the ST Genesia, fibrinogen on the Start, anti-thrombin (AT) on the STA R Max and α2Macroglobulin (α2M) with an in-house chromogenic assay.ResultsTG was measured using STG-BleedScreen, STG-ThromboScreen and STG-DrugScreen. The TG data was used as an input for TD analysis, in combination with plasma levels of AT, α2M and fibrinogen that were 113% (108–118%), 2.6 μM (2.2 μM−3.1 μM) and 2.9 g/L (2.6–3.2 g/L), respectively. The maximum rate of the prothrombinase complex (PCmax) and the total amount of prothrombin converted (PCtot) increased with increasing tissue factor (TF) concentration. PCtot increased from 902 to 988 nM, whereas PCmax increased from 172 to 508 nM/min. Thrombin (T)-AT and T-α2M complexes also increased with increasing TF concentration (i.e., from 860 to 955 nM and from 28 to 33 nm, respectively). PCtot, T-AT and T-α2M complex formation were strongly inhibited by addition of thrombomodulin (−44%, −43%, and −48%, respectively), whereas PCmax was affected less (−24%). PCtot, PCmax, T-AT, and T-α2M were higher in women using oral contraceptives (OC) compared to men/women without OC, and inhibition by thrombomodulin was also significantly less in women on OC (p < 0.05).ConclusionsTG measured on the ST Genesia can be used as an input for TD analysis. The data obtained can be used as reference values for future clinical studies as the balance between prothrombin conversion and thrombin inactivation has shown to be useful in several clinical settings

    Geven om de omgeving : milieugedrag van ondernemingen in de chemische industrie

    Get PDF

    Comparison of effects of anti-thrombin aptamers HD1 and HD22 on aggregation of human platelets, thrombin generation, fibrin formation, and thrombus formation under flow conditions

    Get PDF
    HD1 and HD22 are two of the most-studied aptamers binding to thrombin exosite I and exosite, respectively. To complete of their pharmacological profiles, the effects of HD1 and HD22 on thrombin-, ristocetin-, and collagen-induced human platelet aggregation, on thrombin generation and fibrin formation in human plasma, as well as on thrombus formation in human whole blood under flow conditions were assessed. The dissociation constants for HD1 and HD22 complexes with thrombin in simulated plasma ionic buffer were also evaluated. HD1 was more potent than HD22 in terms of inhibiting thrombin-induced platelet aggregation in platelet-rich plasma (PRP; 0.05-3 mu M) and in washed platelets (WPs; 0.005-3 mu M): approximately 8.31% (+/- 6.99% SD) and 89.53% (+/- 11.38% SD) for HD1 (0.5 mu M) and HD22 (0.5 mu M), respectively. Neither HD1 nor HD22 (3 mu M) did influence platelets aggregation induced by collagen. Both of them inhibited ristocetin-induced aggregation in PRP. Surprisingly, HD1 and HD22 aptamers (3 mu M) potentiated ristocetin-induced platelet aggregation in WP. HD1 reduced thrombin generation in a concentration-dependent manner [ETP at 3 mu M: 1677.53 +/- 55.77 (nM +/- min) vs. control 2271.71 +/- 423.66 (nM +/- min)], inhibited fibrin formation (lag time at 3 mu M: 33.70 min +/- 8.01 min vs. control 7.91 min +/- 0.91 min) and reduced thrombus formation under flow conditions [AUC(30) at 3 mu M: 758.30 +/- 344.23 (kPa +/- min) vs. control 1553.84 +/- 118.03 (kPa +/- min)]. HD22 (3 mu M) also delayed thrombin generation but increased the thrombin peak. HD22 (3 mu M) shortened the lag time of fibrin generation (5.40 min +/- 0.26 min vs. control 7.58 min +/- 1.14 min) but did not modify thrombus formation (3, 15 mu M). K-d values for the HD1 complex with thrombin was higher (257.8 +/- 15.0 nM) than the K-d for HD22 (97.6 +/- 2.2 nM). In conclusion, HD1 but not HD22 represents a potent anti-thrombotic agent, confirming the major role of exosite I in the action of thrombin. HD22 aptamer blocking exosite II displays weaker anti-platelet and anti-coagulant activity, with surprising activating effects on thrombin and fibrin generation most likely induced by HD22-induced allosteric changes in thrombin dynamic structure.</p

    Active von Willebrand Factor in patients with a bleeding diathesis

    Get PDF
    Introduction: Increased levels of circulating von Willebrand Factor (VWF) in its active, platelet-binding conformation have been implicated in the pathogenesis of several thrombotic conditions as well as bleeding conditions characterized by severe thrombocytopenia. However, it is unclear whether the proportion of activated VWF in the circulation also plays a role in patients with mild to moderate bleeding without thrombocytopenia. Methods: Citrated plasma samples were collected from 145 patients with a bleeding diathesis with unknown cause. Active VWF levels were measured with an in-house developed ELISA assay. In addition, VWF antigen (VWF:Ag), VWF ristocetin cofactor activity (VWF:RCo) and (flow-cytometric) platelet-VWF binding (Plt:VWF) were determined. Results: Active VWF levels were on average mildly, but not significantly, lowered in patients with a bleeding diathesis compared to the reference interval (especially in individuals with non-O blood groups). Active VWF was not significantly different for subjects with (median 107.4%, IQR 18.3) versus without (median 111.1%, IQR 32.3%) an increased bleeding score, nor between subjects with suspected VWD (median 104%, IQR 20.6%) versus other suspected causes of bleeding diathesis (median 111.7%, IQR 33.3%). Conclusion: In this clinically heterogeneous population of patients with a mild bleeding phenotype, quantification of active VWF levels does not have added diagnostic value to VWF:Ag and VWF activity assays in the diagnosis of unexplained bleeding disorders

    Comparison of Effects of Anti-thrombin Aptamers HD1 and HD22 on Aggregation of Human Platelets, Thrombin Generation, Fibrin Formation, and Thrombus Formation Under Flow Conditions

    Get PDF
    HD1 and HD22 are two of the most-studied aptamers binding to thrombin exosite I and exosite, respectively. To complete of their pharmacological profiles, the effects of HD1 and HD22 on thrombin-, ristocetin-, and collagen-induced human platelet aggregation, on thrombin generation and fibrin formation in human plasma, as well as on thrombus formation in human whole blood under flow conditions were assessed. The dissociation constants for HD1 and HD22 complexes with thrombin in simulated plasma ionic buffer were also evaluated. HD1 was more potent than HD22 in terms of inhibiting thrombin-induced platelet aggregation in platelet-rich plasma (PRP; 0.05–3 μM) and in washed platelets (WPs; 0.005–3 μM): approximately 8.31% (±6.99% SD) and 89.53% (±11.38% SD) for HD1 (0.5 μM) and HD22 (0.5 μM), respectively. Neither HD1 nor HD22 (3 μM) did influence platelets aggregation induced by collagen. Both of them inhibited ristocetin-induced aggregation in PRP. Surprisingly, HD1 and HD22 aptamers (3 μM) potentiated ristocetin-induced platelet aggregation in WP. HD1 reduced thrombin generation in a concentration-dependent manner [ETP at 3 μM: 1677.53 ± 55.77 (nM⋅min) vs. control 2271.71 ± 423.66 (nM⋅min)], inhibited fibrin formation (lag time at 3 μM: 33.70 min ± 8.01 min vs. control 7.91 min ± 0.91 min) and reduced thrombus formation under flow conditions [AUC30 at 3 μM: 758.30 ± 344.23 (kPa⋅min) vs. control 1553.84 ± 118.03 (kPa⋅min)]. HD22 (3 μM) also delayed thrombin generation but increased the thrombin peak. HD22 (3 μM) shortened the lag time of fibrin generation (5.40 min ± 0.26 min vs. control 7.58 min ± 1.14 min) but did not modify thrombus formation (3, 15 μM). Kd values for the HD1 complex with thrombin was higher (257.8 ± 15.0 nM) than the Kd for HD22 (97.6 ± 2.2 nM). In conclusion, HD1 but not HD22 represents a potent anti-thrombotic agent, confirming the major role of exosite I in the action of thrombin. HD22 aptamer blocking exosite II displays weaker anti-platelet and anti-coagulant activity, with surprising activating effects on thrombin and fibrin generation most likely induced by HD22-induced allosteric changes in thrombin dynamic structure

    Deciphering the coagulation profile through the dynamics of thrombin activity

    Get PDF
    Thrombosis has proven to be extremely difficult to predict. Measuring the generation of thrombin is a very sensitive method to detect changes in the hemostatic system. We developed a method based on the generation of thrombin to further fingerprint hemostasis, which we have named thrombin dynamics. Via this method we are able to exactly measure the prothrombin conversion and thrombin inactivation, and any change in the coagulation cascade will be reflected in these two processes. In the current study we analyzed the importance of the members of the pr

    Optimized electrocardiographic criteria for the detection of left ventricular hypertrophy in obesity patients

    Get PDF
    Background: Despite a generally high specificity, electrocardiographic (ECG) criteria for the detection of left ventricular hypertrophy (LVH) lack sensitivity, particularly in obesity patients. Objectives: The aim of the study was to evaluate the accuracy of the most commonly used ECG criteria (Cornell voltage and Sokolow-Lyon index), the recently introduced Peguero-Lo Presti criteria and the correction of these criteria by body mass index (BMI) to detect LVH in obesity patients and to propose adjusted ECG criteria with optimal accuracy. Methods: The accuracy of the ECG criteria for the detection of LVH was retrospectively tested in a cohort of obesity patients referred for a transthoracic echocardiogram based on clinical grounds (test cohort, n = 167). Adjusted ECG criteria with optimal sensitivity for the detection of LVH were developed. Subsequently, the value of these criteria was prospectively tested in an obese population without known cardiovascular disease (validation cohort, n = 100). Results: Established ECG criteria had a poor sensitivity in obesity patients in both the test cohort and the validation cohort. The adjusted criteria showed improved sensitivity, with optimal values for males using the Cornell voltage corrected for BMI, (RaVL+SV3)*BMI ≥700 mm*kg/m2; sensitivity 47% test cohort, 40% validation cohort; for females, the Sokolow-Lyon index corrected for BMI, (SV1 + RV5/RV6)*BMI ≥885 mm*kg/m2; sensitivity 26% test cohort, 23% validation cohort. Conclusions: Established ECG criteria for the detection of LVH lack sufficient sensitivity in obesity patients. We propose new criteria for the detection of LVH in obesit
    • …
    corecore