10 research outputs found

    Comments on the Preliminary Framework for Equitable Allocation of COVID-19 Vaccine

    Get PDF
    On September 1, 2020 the National Academies released a draft framework for Equitable Allocation of a COVID-19 Vaccine. In this response, we analyze the proposed framework and highlight several areas. Among the proposed changes, we highlight the need for the following interventions. The final framework for distribution of COVID-19 vaccines should give a higher priority to populations made most vulnerable by the social determinants of health. It should incorporate more geography-based approaches in at least some of the four proposed phases of vaccine distribution. It should address the possibility of a vaccine being made available through an emergency use authorization (EUA), which we argue should not serve as a basis for widespread distribution of COVID-19 vaccines, and which may not be appropriate at all for the regulatory review of new vaccines. Moreover, it should address potential adjustments to the allocative framework once additional data pertaining to multiple vaccines becomes available, especially by discussing whether steps should be taken to prevent the administration of different vaccines to the same individual. Finally, it should provide guidance on allocation of vaccine in the case of a surplus, and specifically the Committee should specify whether unused doses of vaccine would automatically be allocated to next-level priority populations, and whether that would take place in the same geographical area

    Comments on the Preliminary Framework for Equitable Allocation of COVID-19 Vaccine

    Get PDF
    On September 1, 2020 the National Academies released a draft framework for Equitable Allocation of a COVID-19 Vaccine. In this response, we analyze the proposed framework and highlight several areas. Among the proposed changes, we highlight the need for the following interventions. The final framework for distribution of COVID-19 vaccines should give a higher priority to populations made most vulnerable by the social determinants of health. It should incorporate more geography-based approaches in at least some of the four proposed phases of vaccine distribution. It should address the possibility of a vaccine being made available through an emergency use authorization (EUA), which we argue should not serve as a basis for widespread distribution of COVID-19 vaccines, and which may not be appropriate at all for the regulatory review of new vaccines. Moreover, it should address potential adjustments to the allocative framework once additional data pertaining to multiple vaccines becomes available, especially by discussing whether steps should be taken to prevent the administration of different vaccines to the same individual. Finally, it should provide guidance on allocation of vaccine in the case of a surplus, and specifically the Committee should specify whether unused doses of vaccine would automatically be allocated to next-level priority populations, and whether that would take place in the same geographical area

    Millimeter-sized marine plastics: a new pelagic habitat for microorganisms and invertebrates

    Get PDF
    Millimeter-sized plastics are abundant in most marine surface waters, and known to carry fouling organisms that potentially play key roles in the fate and ecological impacts of plastic pollution. In this study we used scanning electron microscopy to characterize biodiversity of organisms on the surface of 68 small floating plastics (length range = 1.7–24.3 mm, median = 3.2 mm) from Australia-wide coastal and oceanic, tropical to temperate sample collections. Diatoms were the most diverse group of plastic colonizers, represented by 14 genera. We also recorded ‘epiplastic’ coccolithophores (7 genera), bryozoans, barnacles (Lepas spp.), a dinoflagellate (Ceratium), an isopod (Asellota), a marine worm, marine insect eggs (Halobates sp.), as well as rounded, elongated, and spiral cells putatively identified as bacteria, cyanobacteria, and fungi. Furthermore, we observed a variety of plastic surface microtextures, including pits and grooves conforming to the shape of microorganisms, suggesting that biota may play an important role in plastic degradation. This study highlights how anthropogenic millimeter-sized polymers have created a new pelagic habitat for microorganisms and invertebrates. The ecological ramifications of this phenomenon for marine organism dispersal, ocean productivity, and biotransfer of plastic-associated pollutants, remains to be elucidated

    ILC Reference Design Report Volume 1 - Executive Summary

    No full text
    The International Linear Collider (ILC) is a 200-500 GeV center-of-mass high-luminosity linear electron-positron collider, based on 1.3 GHz superconducting radio-frequency (SCRF) accelerating cavities. The ILC has a total footprint of about 31 km and is designed for a peak luminosity of 2x10^34 cm^-2s^-1. This report is the Executive Summary (Volume I) of the four volume Reference Design Report. It gives an overview of the physics at the ILC, the accelerator design and value estimate, the detector concepts, and the next steps towards project realization.The International Linear Collider (ILC) is a 200-500 GeV center-of-mass high-luminosity linear electron-positron collider, based on 1.3 GHz superconducting radio-frequency (SCRF) accelerating cavities. The ILC has a total footprint of about 31 km and is designed for a peak luminosity of 2x10^34 cm^-2s^-1. This report is the Executive Summary (Volume I) of the four volume Reference Design Report. It gives an overview of the physics at the ILC, the accelerator design and value estimate, the detector concepts, and the next steps towards project realization

    ILC Reference Design Report Volume 4 - Detectors

    No full text
    This report, Volume IV of the International Linear Collider Reference Design Report, describes the detectors which will record and measure the charged and neutral particles produced in the ILC's high energy e+e- collisions. The physics of the ILC, and the environment of the machine-detector interface, pose new challenges for detector design. Several conceptual designs for the detector promise the needed performance, and ongoing detector R&D is addressing the outstanding technological issues. Two such detectors, operating in push-pull mode, perfectly instrument the ILC interaction region, and access the full potential of ILC physics.This report, Volume IV of the International Linear Collider Reference Design Report, describes the detectors which will record and measure the charged and neutral particles produced in the ILC's high energy e+e- collisions. The physics of the ILC, and the environment of the machine-detector interface, pose new challenges for detector design. Several conceptual designs for the detector promise the needed performance, and ongoing detector R&D is addressing the outstanding technological issues. Two such detectors, operating in push-pull mode, perfectly instrument the ILC interaction region, and access the full potential of ILC physics

    ILC Reference Design Report Volume 3 - Accelerator

    No full text
    The International Linear Collider (ILC) is a 200-500 GeV center-of-mass high-luminosity linear electron-positron collider, based on 1.3 GHz superconducting radio-frequency (SCRF) accelerating cavities. The ILC has a total footprint of about 31 km and is designed for a peak luminosity of 2x10^34 cm^-2 s^-1. The complex includes a polarized electron source, an undulator-based positron source, two 6.7 km circumference damping rings, two-stage bunch compressors, two 11 km long main linacs and a 4.5 km long beam delivery system. This report is Volume III (Accelerator) of the four volume Reference Design Report, which describes the design and cost of the ILC.The International Linear Collider (ILC) is a 200-500 GeV center-of-mass high-luminosity linear electron-positron collider, based on 1.3 GHz superconducting radio-frequency (SCRF) accelerating cavities. The ILC has a total footprint of about 31 km and is designed for a peak luminosity of 2x10^34 cm^-2 s^-1. The complex includes a polarized electron source, an undulator-based positron source, two 6.7 km circumference damping rings, two-stage bunch compressors, two 11 km long main linacs and a 4.5 km long beam delivery system. This report is Volume III (Accelerator) of the four volume Reference Design Report, which describes the design and cost of the ILC

    International Linear Collider Reference Design Report Volume 2: PHYSICS AT THE ILC

    No full text
    This article reviews the physics case for the ILC. Baseline running at 500 GeV as well as possible upgrades and options are discussed. The opportunities on Standard Model physics, Higgs physics, Supersymmetry and alternative theories beyond the Standard Model are described.This article reviews the physics case for the ILC. Baseline running at 500 GeV as well as possible upgrades and options are discussed. The opportunities on Standard Model physics, Higgs physics, Supersymmetry and alternative theories beyond the Standard Model are described
    corecore