1,519 research outputs found
CoGeNT: A Search for Low-Mass Dark Matter using p-type Point Contact Germanium Detectors
CoGeNT employs p-type point-contact (PPC) germanium detectors to search for
Weakly Interacting Massive Particles (WIMPs). By virtue of its low energy
threshold and ability to reject surface backgrounds, this type of device allows
an emphasis on low-mass dark matter candidates (wimp mass of about 10 GeV/c2).
We report on the characteristics of the PPC detector presently taking data at
the Soudan Underground Laboratory, elaborating on aspects of shielding, data
acquisition, instrumental stability, data analysis, and background estimation.
A detailed background model is used to investigate the low energy excess of
events previously reported, and to assess the possibility of temporal
modulations in the low-energy event rate. Extensive simulations of all
presently known backgrounds do not provide a viable background explanation for
the excess of low-energy events in the CoGeNT data, or the previously observed
temporal variation in the event rate. Also reported on for the first time is a
determination of the surface (slow pulse rise time) event contamination in the
data as a function of energy. We conclude that the CoGeNT detector technology
is well suited to search for the annual modulation signature expected from dark
matter particle interactions in the region of WIMP mass and coupling favored by
the DAMA/LIBRA resultsComment: 20 pages, 31 figures. Several figures have been added, including an
updated allowed region (both 90% and 99% confidence level contours) based on
this analysis. There is also the addition of a Pb-210 background estimat
Large-Mass Ultra-Low Noise Germanium Detectors: Performance and Applications in Neutrino and Astroparticle Physics
A new type of radiation detector, a p-type modified electrode germanium
diode, is presented. The prototype displays, for the first time, a combination
of features (mass, energy threshold and background expectation) required for a
measurement of coherent neutrino-nucleus scattering in a nuclear reactor
experiment. The device hybridizes the mass and energy resolution of a
conventional HPGe coaxial gamma spectrometer with the low electronic noise and
threshold of a small x-ray semiconductor detector, also displaying an intrinsic
ability to distinguish multiple from single-site particle interactions. The
present performance of the prototype and possible further improvements are
discussed, as well as other applications for this new type of device in
neutrino and astroparticle physics (double-beta decay, neutrino magnetic moment
and WIMP searches).Comment: submitted to Phys. Rev.
Experimental constraints on a dark matter origin for the DAMA annual modulation effect
A claim for evidence of dark matter interactions in the DAMA experiment has
been recently reinforced. We employ a new type of germanium detector to
conclusively rule out a standard isothermal galactic halo of Weakly Interacting
Massive Particles (WIMPs) as the explanation for the annual modulation effect
leading to the claim. Bounds are similarly imposed on a suggestion that dark
pseudoscalars mightlead to the effect. We describe the sensitivity to light
dark matter particles achievable with our device, in particular to
Next-to-Minimal Supersymmetric Model candidates.Comment: v4: introduces recent results from arXiv:0807.3279 and
arXiv:0807.2926. Sensitivity to pseudoscalars is revised in light of the
first. Discussion on the subject adde
Results from a Search for Light-Mass Dark Matter with a P-type Point Contact Germanium Detector
We report on several features present in the energy spectrum from an ultra
low-noise germanium detector operated at 2,100 m.w.e. By implementing a new
technique able to reject surface events, a number of cosmogenic peaks can be
observed for the first time. We discuss several possible causes for an
irreducible excess of bulk-like events below 3 keVee, including a dark matter
candidate common to the DAMA/LIBRA annual modulation effect, the hint of a
signal in CDMS, and phenomenological predictions. Improved constraints are
placed on a cosmological origin for the DAMA/LIBRA effect.Comment: 4 pages, 4 figures. v2: submitted version. Minimal changes in
wording, one reference adde
Signal modeling of high-purity Ge detectors with a small read-out electrode and application to neutrinoless double beta decay search in Ge-76
The GERDA experiment searches for the neutrinoless double beta decay of Ge-76
using high-purity germanium detectors enriched in Ge-76. The analysis of the
signal time structure provides a powerful tool to identify neutrinoless double
beta decay events and to discriminate them from gamma-ray induced backgrounds.
Enhanced pulse shape discrimination capabilities of "Broad Energy Germanium"
detectors with a small read-out electrode have been recently reported. This
paper describes the full simulation of the response of such a detector,
including the Monte Carlo modeling of radiation interaction and subsequent
signal shape calculation. A pulse shape discrimination method based on the
ratio between the maximum current signal amplitude and the event energy applied
to the simulated data shows quantitative agreement with the experimental data
acquired with calibration sources. The simulation has been used to study the
survival probabilities of the decays which occur inside the detector volume and
are difficult to assess experimentally. Such internal decay events are produced
by the cosmogenic radio-isotopes Ge-68 and Co-60 and the neutrinoless double
beta decay of Ge-76. Fixing the experimental acceptance of the double escape
peak of the 2.614 MeV photon to 90%, the estimated survival probabilities at
Qbb = 2.039 MeV are (86+-3)% for Ge-76 neutrinoless double beta decays,
(4.5+-0.3)% for the Ge-68 daughter Ga-68, and (0.9+0.4-0.2)% for Co-60 decays.Comment: 27 pages, 17 figures. v2: fixed typos and references. Submitted to
JINS
The Majorana Project
Building a \BBz experiment with the ability to probe neutrino mass in the
inverted hierarchy region requires the combination of a large detector mass
sensitive to \BBz, on the order of 1-tonne, and unprecedented background
levels, on the order of or less than 1 count per year in the \BBz signal
region. The MAJORANA Collaboration proposes a design based on using high-purity
enriched Ge-76 crystals deployed in ultra-low background electroformed Cu
cryostats and using modern analysis techniques that should be capable of
reaching the required sensitivity while also being scalable to a 1-tonne size.
To demonstrate feasibility, the collaboration plans to construct a prototype
system, the MAJORANA DEMONSTRATOR, consisting of 30 kg of 86% enriched \Ge-76
detectors and 30 kg of natural or isotope-76-depleted Ge detectors. We plan to
deploy and evaluate two different Ge detector technologies, one based on a
p-type configuration and the other on n-type.Comment: paper submitted for the 2008 Carolina International Symposium on
Neutrino Physic
The Majorana experiment: an ultra-low background search for neutrinoless double-beta decay
The observation of neutrinoless double-beta decay would resolve the Majorana
nature of the neutrino and could provide information on the absolute scale of
the neutrino mass. The initial phase of the Majorana experiment, known as the
Demonstrator, will house 40 kg of Ge in an ultra-low background shielded
environment at the 4850' level of the Sanford Underground Laboratory in Lead,
SD. The objective of the Demonstrator is to determine whether a future 1-tonne
experiment can achieve a background goal of one count per tonne-year in a
narrow region of interest around the 76Ge neutrinoless double-beta decay peak.Comment: Presentation for the Rutherford Centennial Conference on Nuclear
Physic
Risk assessment for the spread of Serratia marcescens within dental-unit waterline systems using Vermamoeba vermiformis
Vermamoeba vermiformis is associated with the biofilm ecology of dental-unit waterlines (DUWLs). This study investigated whether V. vermiformis is able to act as a vector for potentially pathogenic bacteria and so aid their dispersal within DUWL systems. Clinical dental water was initially examined for Legionella species by inoculating it onto Legionella selective-medium plates. The molecular identity/profile of the glassy colonies obtained indicated none of these isolates were Legionella species. During this work bacterial colonies were identified as a non-pigmented Serratia marcescens. As the water was from a clinical DUWL which had been treated with Alpron™ this prompted the question as to whether S. marcescens had developed resistance to the biocide. Exposure to Alpron™ indicated that this dental biocide was effective, under laboratory conditions, against S. marcescens at up to 1x108 colony forming units/millilitre (cfu/ml). V. vermiformis was cultured for eight weeks on cells of S. marcescens and Escherichia coli. Subsequent electron microscopy showed that V. vermiformis grew equally well on S. marcescens and E. coli (p = 0.0001). Failure to detect the presence of S. marcescens within the encysted amoebae suggests that V. vermiformis is unlikely to act as a vector supporting the growth of this newly isolated, nosocomial bacterium
- …
