12 research outputs found

    Radio Frequency MRI coils and safety: how infrared thermography can support quality assurance

    Get PDF
    Abstract Background The safety controls in Resonance Magnetic Imaging (MRI) diagnostic site are numerous and complex. Some of these are contained in international directives and regularly conducted by medical physics expert after acceptance tests, consisting of a series of checks, measurements, evaluations called quality controls (QCs) and made to guarantee the image quality of the equipment. In this context, ensuring that the coils are in proper operating conditions is important to prevent and reduce errors in use and to preserve patient safety. Results A study by thermography was conducted to evaluate temperature changes of MRI coils during Quality Control (QC), in order to prevent any problems for the patient due to Radio Frequency waves. This experiment involves use of a thermal camera to detect temperature variations during MRI scans using head and body coils of two different tomography 1.5 T and 3.0 T static magnetic field. Thermal camera was positioned inside the MRI room to acquire images every 15 s for all the scansions duration. The observations have shown a temperature increase only for body coil of 1.5 MRI tomography, whereas no significative temperature variation has occurred for the other coils under observation. This temperature increase was later related to a fault of such coil. Conclusions The authors believe this simple method useful as first approach, during routinely QCs, to verify coils functioning and so to avoid patient hazards and are preparing a methodological study about functioning of the coils with respect to their temperature variation

    Irradiation with Polychromatic Incoherent Low Energy Radiation of Human Peripheral Blood Mononuclear Cells In Vitro: Effects on Cytokine Production

    No full text
    (1) Background: Physical stimuli may activate peripheral blood mononuclear cells (PBMCs) to secrete cytokines, which may favor pro-inflammatory responses or trigger reparative phenomena. The purpose of this study is to evaluate the action of Polarized Polychromatic Incoherent Low Energy Radiation (PILER) on human in vitro PBMCs, by detection of the possible effects on cytokine production; (2) Methods: isolated PBMCs were irradiated with a PILER lamp at different exposure times, at a distance of 10 cm, before incubation. The supernatants were collected after 24 h and 48 h and cytokines evaluated by ELISA; (3) Results: Our results showed a decrease in the levels of pro-inflammatory IL-12p70, IL-17A, IFN-γ, and TNF-α cytokines, whereas IL-10 and TGF-β1 with regulatory activity increased; (4) Conclusions: PILER irradiation affected the cytokine production by isolated PBMCs driving the immune response toward an anti-inflammatory/reparative profile

    An Alternative Approach to Cataract Surgery Using BSS Temperature of 2.7 °C

    No full text
    The aim of this study is to evaluate the difference in the number of endothelial cells after cataract operations with phacoemulsification by using a balanced salt solution (BSS) at standard temperature (about 20 °C) and at 2.7 °C. Two groups, comprising 214 individuals in total, participated in this study; patients were operated on using BSS bottle at about 20 °C and 2.7 °C in the first and second groups, respectively. All operations were conducted by the same surgeon and in similar conditions. One month after the operations, endothelial cells in the two groups were checked. For patients in Group 2, an important reduction in the loss of endothelial cells was observed

    Use of Raman Spectroscopy, Scanning Electron Microscopy and Energy Dispersive X-ray Spectroscopy in a Multi-Technique Approach for Physical Characterization of Purple Urine Bag Syndrome

    No full text
    Purple urine bag syndrome (PUBS) is a rare condition characterized by purple discoloration of urine and urine bags. Although it is benign, it represents an alarming symptom to the patients and their relatives because of purple discoloration. We have physically characterized urine and urine bags belonging to a patient suffering from PUBS using an approach that combines Raman spectroscopy (RS) and scanning electron microscopy (SEM) coupled with energy dispersive X-ray (EDX). Five “blue” discolored bags and one sterile urine bag, representing the control, were cut into 1 cm2 square samples and analyzed by using RS and SEM + EDX technique. RS enabled us to identify the presence of indigo, a metabolite of tryptophan, while SEM analysis showed the biofilm deposit, probably due to the presence of microorganisms, and the EDX measurements exhibited the elemental composition of the bags. In particular, urine bags before and after the presence of PUBS urine showed an increase of ~32% of Cl, ~33% of O, ~667% of Ca, ~65% of Al and Mg, while C decreased by about 41%. Our results, to be taken as a proof-of-principle study, are promising for the aim to characterizing the urine bags in a flexible, inexpensive, and comprehensive manner

    Raman Spectroscopic Study of Amyloid Deposits in Gelatinous Drop-like Corneal Dystrophy

    No full text
    The genetic and histopathological features of the cornea of a Polish patient with Gelatinous Drop-like Corneal Dystrophy (GDCD) and the molecular composition with Raman spectroscopy of corneal deposits were examined. A 62 year-old Polish woman was diagnosed with GDCD and underwent penetrating corneal transplant. A blood sample was collected, and genetic analysis was performed. The cornea was processed for light microscopy and Raman analysis. The genetic exam revealed a previously undescribed homozygous 1-base pair deletion in exon 1 of TACSTD2 gene (c.185delT), resulting in a frame shift causing a premature stop codon. When compared with a control cornea, in GDCD cornea stained with PAS evident deposits were present over the anterior stroma, with apple green birefringence under polarized light. Raman spectroscopy showed peculiar differences between normal and GDCD cornea, consisting in peaks either of different height or undetectable in the normal cornea and related to amyloid. The possible causative role of the novel mutation was discussed and Raman spectroscopy as a further morphological tool in the evaluation of corneal dystrophies, characterized by the deposition of abnormal materials, was suggested

    dB/dt Evaluation in MRI Sites: Is ICNIRP Threshold Limit (for Workers) Exceeded?

    No full text
    The Directive 2013/35/EU establishes standards for workers exposed to static and time varying magnetic fields. These limits are based on ICNIRP guidelines expressed in terms of the electric field induced in the body. The complexity of this measurement led to theoretical models being developed. In this study, the experimental evaluation included varying magnetic field exposures for two classes of MRI workers. The measurements are conducted on four different MRI Systems including one 0.35 T, two 1.5 T, and one 3.0 T. Pocket magnetic dosimeters were used and it was carried out during routine conditions, emergency conditions, and cold-head maintenance/substitution. The acquired data has been processed and the corresponding dB/dt curves have been computed as the first time derivative of the dataset. The weighted peak approach was also implemented for the compliance assessment with regulatory limits. The dB/dt peak values have been compared with the reference level (RL) proposed by ICNIRP. The results show that the RL always exceeds during measurements on the 3.0 T scanner and sometimes on 1.5 T. In light of the foregoing, the diffusion of ultra-high field MRI scanners involves the introduction of behavioral rules that could be more useful than a numerical action level

    Rutin-Loaded Solid Lipid Nanoparticles: Characterization and In Vitro Evaluation

    No full text
    This study was aimed at preparing and characterizing solid lipid nanoparticles loading rutin (RT-SLNs) for the treatment of oxidative stress-induced diseases. Phospholipon 80H® as a solid lipid and Polysorbate 80 as surfactant were used for the SLNs preparation, using the solvent emulsification/diffusion method. We obtained spherical RT-SLNs with low sizes, ranging from 40 to 60 nm (hydrodynamic radius) for the SLNs prepared starting from 2% and 5% (w/w) theoretical amount. All prepared formulations showed negative zeta-potential values. RT was efficiently encapsulated within SLNs, obtaining high encapsulation efficiency and drug content percentages, particularly for SLNs prepared with a 5% theoretical amount of RT. In vitro release profiles and analysis of the obtained data applying different kinetic models revealed Fickian diffusion as the main mechanism of RT release from the SLNs. The morphology of RT-SLNs was characterized by scanning electron microscopy (SEM), whereas the interactions between RT and the lipid matrix were investigated by Raman spectroscopy, evidencing spectral modifications of characteristic bands of RT due to the establishment of new interactions. Finally, antioxidant activity assay on human glioblastoma astrocytoma (U373) culture cells showed a dose-dependent activity for RT-SLNs, particularly at the highest assayed dose (50 μM), whereas the free drug showed the lesser activity
    corecore