4 research outputs found
The Application of Multilinear Regression Model for Quantitative Analysis on the Basis of Excitation-Emission Matrix Spectra and the Release of a Free Graphical User Interface
Multivariate regression is a fundamental supervised chemometric method for developing the relationship between the independent variables and quantitative response, and it has been widely applied for data analysis in many research fields. In this study, we propose an effective method for the quantitative determination of target compounds in traditional Chinese medicine, specifically Mongolia, using excitation-emission matrix (EEM) spectra with partial overlap. The accuracy and reliability of the established model have been validated, demonstrating that the proposed method can realize the accurate quantitative analysis purpose. In order to facilitate the calculation easier, the authors have developed a friendly graphical user interface (GUI). The GUI offers the procedures for data imputation, model establishment, model optimization and results presentation
New Constructed EEM Spectra Combined with N-PLS Analysis Approach as an Effective Way to Determine Multiple Target Compounds in Complex Samples
Excitation–emission matrix (EEM) fluorescence spectroscopy has been applied to many fields. In this study, a simple method was proposed to obtain the new constructed three-dimensional (3D) EEM spectra based on the original EEM spectra. Then, the application of the N-PLS method to the new constructed 3D EEM spectra was proposed to quantify target compounds in two complex data sets. The quantitative models were established on external sample sets and validated using statistical parameters. For validation purposes, the obtained results were compared with those obtained by applying the N-PLS method to the original EEM spectra and applying the PLS method to the extracted maximum spectra in the concatenated mode. The comparison of the results demonstrated that, given the advantages of less useless information and a high calculating speed of the new constructed 3D EEM spectra, N-PLS on the new constructed 3D EEM spectra obtained better quantitative analysis results with a correlation coefficient of prediction above 0.9906 and recovery values in the range of 85.6–95.6%. Therefore, one can conclude that the N-PLS method combined with the new constructed 3D EEM spectra is expected to be broadened as an alternative strategy for the simultaneous determination of multiple target compounds