13 research outputs found
Limbitis Secondary to Autologous Serum Eye Drops in a Patient with Atopic Keratoconjunctivitis
Purpose. Report a case of limbitis secondary to autologous serum eye drops in a patient with atopic keratoconjunctivitis. Design. Interventional case report. Methods. A 32-year-old African American female with atopic keratoconjunctivitis (AKC) presented with chronic dry eye and diffuse punctate epithelial erosions refractory to conservative treatment. She was initially managed with cyclosporine ophthalmic 0.05% in addition to preservative-free artificial tears and olopatadine hydrochloride 0.2% for 6 months. She was later placed on autologous serum eye drops (ASEDs) and 4 weeks into treatment developed unilateral limbitis. The limbitis resolved shortly after stopping ASEDs in that eye; however, the drops were continued in the contralateral eye, which subsequently developed limbitis within 2 weeks. ASEDs were discontinued in both eyes, and the patient has remained quiet ever since. Results. Patient with a history of AKC and no prior history of limbitis developed limbitis shortly after starting ASEDs, which resolved promptly after discontinuation of therapy with no subsequent recurrence of inflammation. Conclusion. ASEDs are widely used in the treatment of complicated or treatment refractory dry eye. The potential side effects should be kept in mind when prescribing ASEDs for any patient, especially in those with underlying immunological diseases and circulating inflammatory factors
Update on Limbal Stem Cell Transplantation
Limbal epithelial stem cells are the primary source of corneal epithelial cell regeneration. Limbal stem cell deficiency (LSCD) can develop in traumatic, immunologic, or genetic diseases that affect the ocular surface. LSCD leads to conjunctivalization, with corneal vascularization and opacification and subsequent loss of vision. Limbal stem cell transplantation is a surgical treatment to address LSCD and restore a corneal epithelial phenotype. Based on the source of cells, limbal transplant can be autologous or allogenic. Many surgical techniques are defined according to the source of the stem cells and the carrier tissues that are used. More recently, ex vivo expanded bioengineered epithelial cells have been used to reconstruct the corneal surface using autologous cells to eliminate the risk of rejection. Before transplantation, a systematic exam of the lids, eyelashes, fornices, and aqueous tears is mandatory and every effort should be made to optimize ocular surface health and control inflammation to enhance the chances of graft survival. Postoperative care is also another major determinant of success. Any factor that destabilizes the ocular surface needs to be addressed. In addition, systemic and topical immunosuppressants are also needed in all allograft recipients. In addition to pre-operative and postoperative care and the surgery itself, the etiology of LSCD also has an impact on the outcome. The prognosis of inflammatory diseases such as Stevens-Johnson syndrome is the worst among disorders causing LSCD
Central Corneal Thickness, Corneal Endothelial Characteristics and Intraocular Pressure after Pediatric Cataract Surgery
<!--[if gte mso 9]><xml> Normal 0 false false false MicrosoftInternetExplorer4 </xml><![endif]--><!--[if gte mso 9]><xml> </xml><![endif]--> <!--[if gte mso 10]> <style> /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-parent:""; mso-padding-alt:0cm 5.4pt 0cm 5.4pt; mso-para-margin:0cm; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:10.0pt; font-family:"Times New Roman"; mso-ansi-language:#0400; mso-fareast-language:#0400; mso-bidi-language:#0400;} </style> <![endif]--> <p>PURPOSE: To investigate central corneal thickness (CCT), endothelial cell characteristics and intraocular pressure (IOP) in eyes with prior pediatric cataract surgery and to compare them with eyes of normal age and sex matched controls. METHODS: Specular microscopy CCT and IOP measurements were performed in 31 eyes of 17 patients with prior congenital cataract extraction and 40 eyes of 20 age and sex matched subjects. The mean of three pachymetric and specular microscopic measurements were recorded. IOP was measured using Goldmann applanation tonometry. RESULTS: Mean CCT was 632±45 µm in eyes with prior pediatric cataract surgery vs 546±33 µm in control eyes (P < 0.001, independent t test and Mann Whitney U-test). Mean IOP was 22.1±3.9 mmHg in eyes with prior pediatric cataract surgery and 14.0±1.6 mmHg in the control group (P < 0.001, independent t-test). There was no significant difference between the two groups in cell count, polymegethism and mean cell area of corneal endothelial cells. CONCLUSIONS: Although the corneas were clinically clear and there was no significant difference in endothelial characteristics in eyes with prior pediatric cataract surgery as compared to normal controls, central corneal thickness in the operated eyes was significantly greater. To differentiate actual glaucoma from artifactual IOP increase, CCT measurement should be performed in these patients.</p> <!--[if gte mso 9]><xml> <w:WordDocument> <w:View>Normal</w:View> <w:Zoom>0</w:Zoom> <w:PunctuationKerning /> <w:ValidateAgainstSchemas /> <w:SaveIfXMLInvalid>false</w:SaveIfXMLInvalid> <w:IgnoreMixedContent>false</w:IgnoreMixedContent> <w:AlwaysShowPlaceholderText>false</w:AlwaysShowPlaceholderText> <w:Compatibility> <w:BreakWrappedTables /> <w:SnapToGridInCell /> <w:WrapTextWithPunct /> <w:UseAsianBreakRules /> <w:DontGrowAutofit /> </w:Compatibility> <w:BrowserLevel>MicrosoftInternetExplorer4</w:BrowserLevel> </w:WordDocument> </xml><![endif]--><!--[if gte mso 9]><xml> <w:LatentStyles DefLockedState="false" LatentStyleCount="156"> </w:LatentStyles> </xml><![endif]--> <!-- /* Font Definitions */ @font-face {font-family:Palatino; mso-font-alt:"Book Antiqua"; mso-font-charset:0; mso-generic-font-family:roman; mso-font-pitch:variable; mso-font-signature:7 0 0 0 147 0;} @font-face {font-family:"B Titr"; panose-1:0 0 7 0 0 0 0 0 0 0; mso-font-charset:178; mso-generic-font-family:auto; mso-font-pitch:variable; mso-font-signature:24577 -2147483648 8 0 64 0;} @font-face {font-family:Nazanin; mso-font-alt:"Courier New"; mso-font-charset:178; mso-generic-font-family:auto; mso-font-pitch:variable; mso-font-signature:24577 0 0 0 64 0;} /* Style Definitions */ p.MsoNormal, li.MsoNormal, div.MsoNormal {mso-style-parent:""; margin:0cm; margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; mso-bidi-font-size:12.0pt; font-family:"Times New Roman"; mso-fareast-font-family:"Times New Roman"; mso-bidi-font-family:Nazanin;} @page Section1 {size:612.0pt 792.0pt; margin:72.0pt 90.0pt 72.0pt 90.0pt; mso-header-margin:36.0pt; mso-footer-margin:36.0pt; mso-paper-source:0;} div.Section1 {page:Section1;} --> <!--[if gte mso 10]> <style> /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-parent:""; mso-padding-alt:0cm 5.4pt 0cm 5.4pt; mso-para-margin:0cm; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:10.0pt; font-family:"Times New Roman"; mso-ansi-language:#0400; mso-fareast-language:#0400; mso-bidi-language:#0400;} </style> <![endif]-->
Correlation between Retinal Nerve Fiber Layer Thickness by Optical Coherence Tomography and Perimetric Parameters in Optic Atrophy
<!--[if gte mso 9]><xml> Normal 0 false false false MicrosoftInternetExplorer4 </xml><![endif]--><!--[if gte mso 9]><xml> </xml><![endif]--><!--[if !mso]><object classid="clsid:38481807-CA0E-42D2-BF39-B33AF135CC4D" id=ieooui></object> <style> st1:*{behavior:url(#ieooui) } </style> <![endif]--> <!--[if gte mso 10]> <style> /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-parent:""; mso-padding-alt:0cm 5.4pt 0cm 5.4pt; mso-para-margin:0cm; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:10.0pt; font-family:"Times New Roman"; mso-ansi-language:#0400; mso-fareast-language:#0400; mso-bidi-language:#0400;} </style> <![endif]--> <p>PURPOSE: To investigate the correlation between retinal nerve fiber layer (RNFL) thickness determined by optical coherence tomography (OCT) and visual field (VF) parameters in patients with optic atrophy. METHODS: This study was performed on 35 eyes of 28 patients with optic atrophy. RNFL thickness was measured by OCT (Carl Zeiss, Jena, Germany) and automated perimetry was performed using the Humphrey Field Analyzer (Carl Zeiss, Jena, Germany). The correlation between RNFL thickness and VF parameters was evaluated. RESULTS: Mean global RNFL thickness was 44.9±27.5 µm which was significantly correlated with mean deviation score on automated perimetry (r=0.493, P=0.003); however, no significant correlation was observed between visual field pattern standard deviation and the corresponding quadrantic RNFL thickness. In a similar manner, no significant association was found between visual acuity and RNLF thickness. CONCLUSION: Mean global RNFL thickness as determined by OCT seems to be correlated with VF defect depth as represented by the mean deviation score on Humphrey VF testing. OCT may be used as an objective diagnostic tool in the evaluation of patients with optic atrophy.</p>
Osteogenesis enhancement using poly (l-lactide-co-d, l-lactide)/poly (vinyl alcohol) nanofibrous scaffolds reinforced by phospho-calcified cellulose nanowhiskers
info:eu-repo/semantics/publishe
Surgical and Visual Outcomes of the Type I Boston Keratoprosthesis for the Management of Aniridic Fibrosis Syndrome in Congenital Aniridia
PURPOSE: To report the clinical features and surgical management of aniridic fibrosis syndrome using the type I Boston Keratoprosthesis (KPro).
DESIGN: Interventional case series.
METHODS: Retrospective chart review of 9 eyes in 9 patients with congenital aniridia that developed aniridic fibrosis syndrome.
RESULTS: All patients had clinical diagnosis of congenital aniridia. Previously, all patients had undergone cataract surgery with posterior chamber intraocular lens (IOL) implantation and 7 patients had existing tube shunts. In all cases, fibrosis presented as progressive retrocorneal and retrolenticular membrane formation causing displacement of the IOL and secondary corneal decompensation. Two eyes had tractional folds in the retina with posterior extension of the membrane. The management included IOL explantation in 7 of 9 cases, removal of fibrosis with pars plana vitrectomy in all 9 patients, and implantation of a type I Boston KPro in all eyes. At a mean final follow-up of 26.1 months (range 6 to 48 months), vision remained improved in all patients. No patient had recurrence of the fibrotic membrane after KPro implantation.
CONCLUSION: This study represents another case series describing aniridic fibrosis syndrome and the largest study to report utilization of the type I Boston KPro in such patients. As the fibrosis can cause IOL dislocation, corneal decompensation, hypotony, and retinal detachment, monitoring for aniridic fibrosis syndrome in congenital aniridia with early surgical intervention is recommended. Type I Boston KPro may be considered in the surgical treatment of this conditio
An EPID-based method for comprehensive verification of gantry, EPID and the MLC carriage positional accuracy in Varian linacs during arc treatments
Background]In modern radiotherapy, it is crucial to monitor the performance of all linac components including gantry, collimation system and electronic portal imaging device (EPID) during arc deliveries. In this study, a simple EPID-based measurement method has been introduced in conjunction with an algorithm to investigate the stability of these systems during arc treatments with the aim of ensuring the accuracy of linac mechanical performance. Methods The Varian EPID sag, gantry sag, changes in source-to-detector distance (SDD), EPID and collimator skewness, EPID tilt, and the sag in MLC carriages as a result of linac rotation were separately investigated by acquisition of EPID images of a simple phantom comprised of 5 ball-bearings during arc delivery. A fast and robust software package was developed for automated analysis of image data. Twelve Varian linacs of different models were investigated. Results The average EPID sag was within 1 mm for all tested linacs. All machines showed less than 1 mm gantry sag. Changes in SDD values were within 1.7 mm except for three linacs of one centre which were within 9 mm. Values of EPID skewness and tilt were negligible in all tested linacs. The maximum sag in MLC leaf bank assemblies was around 1 mm. The EPID sag showed a considerable improvement in TrueBeam linacs. Conclusion The methodology and software developed in this study provide a simple tool for effective investigation of the behaviour of linac components with gantry rotation. It is reproducible and accurate and can be easily performed as a routine test in clinics. <br/