92 research outputs found

    Metallo-Graphene Nanocomposite Electrocatalytic Platform for the Determination of Toxic Metal Ions

    Get PDF
    A Nafion-Graphene (Nafion-G) nanocomposite solution in combination with an in situ plated mercury film electrode was used as a highly sensitive electrochemical platform for the determination of Zn2+, Cd2+, Pb2+ and Cu2+ in 0.1 M acetate buffer (pH 4.6) by square-wave anodic stripping voltammetry (SWASV). Various operational parameters such as deposition potential, deposition time and electrode rotation speed were optimized. The Nafion-G nanocomposite sensing platform exhibited improved sensitivity for metal ion detection, in addition to well defined, reproducible and sharp stripping signals. The linear calibration curves ranged from 1 μg L−1 to 7 μg L−1 for individual analysis. The detection limits (3σ blank/slope) obtained were 0.07 μg L−1 for Pb2+, Zn2+ and Cu2+ and 0.08 μg L−1 for Cd2+ at a deposition time of 120 s. For practical applications recovery studies was done by spiking test samples with known concentrations and comparing the results with inductively coupled plasma mass spectrometry (ICP-MS) analyses. This was followed by real sample analysis

    Complexation-based detection of nickel(ii) at a graphene-chelate probe in the presence of cobalt and zinc by adsorptive stripping voltammetry

    Get PDF
    The adsorptive stripping voltammetric detection of nickel and cobalt in water samples at metal film electrodes has been extensively studied. In this work, a novel, environmentally friendly, metal-free electrochemical probe was constructed for the ultra-trace determination of Ni2+ in water samples by Adsorptive Cathodic Stripping Voltammetry (AdCSV). The electrochemical platform is based on the adsorptive accumulation of Ni2+ ions directly onto a glassy carbon electrode (GCE) modified with dimethylglyoxime (DMG) as chelating agent and a Nafion-graphene (NGr) nanocomposite to enhance electrode sensitivity. The nafion-graphene dimethylglyoxime modified glassy carbon electrode (NGr-DMG-GCE) shows superior detection capabilities as a result of the improved surface-area-to-volume ratio and enhanced electron transfer kinetics following the incorporation of single layer graphene, while limiting the toxic effects of the sensor by removal of the more common mercury, bismuth and lead films

    Polyester Sulphonic Acid Interstitial Nanocomposite Platform for Peroxide Biosensor

    Get PDF
    A novel enzyme immobilization platform was prepared on a platinum disk working electrode by polymerizing aniline inside the interstitial pores of polyester sulphonic acid sodium salt (PESA). Scanning electron microscopy study showed the formation of homogeneous sulphonated polyaniline (PANI) nanotubes (∼90 nm) and thermogravimetric analysis (TGA) confirmed that the nanotubes were stable up to 230 °C. The PANI:PESA nanocomposite showed a quasi-reversible redox behaviour in phosphate buffer saline. Horseradish peroxidase (HRP) was immobilized on to this modified electrode for hydrogen peroxide detection. The biosensor gave a sensitivity of 1.33 μA (μM)-1 and a detection limit of 0.185 μM for H2O2. Stability experiments showed that the biosensor retained more than 64% of its initial sensitivity over four days of storage at 4 °C

    Microwave-assisted synthesis of schiff base metal–ligand complexes with copper and nickel centres for electrochemical in vitro sensing of nitric oxide in an aqueous solution

    Get PDF
    Nitric oxide (NO), the smallest signalling molecule known in the human body, keeps blood vessels dilated, controls blood pressure, and has numerous other health regulatory effects. The use of Schiff base complexes incorporated onto electrodes to make electrochemical sensors has been explored as an effective method for the determination and quantification of nitric oxide in aqueous solutions. Schiff base ligands were complexed with Cu and Ni metal centres using the microwave synthesis method to produce metal–ligand complexes with enhanced capabilites for NO detection. The electrical current generated at the anode is directly proportional to NO concentrations in the solution through its oxidation to HNO3 . Various characterisation techniques were implemented to verify the integrity of each step of metal–ligand synthesis as well as the final product produced, using FT-IR, UV-VIS, and TGA

    A fumonisins immunosensor based on polyanilino-carbon nanotubes doped with palladium telluride quantum dots

    Get PDF
    An impedimetric immunosensor for fumonisins was developed based on poly(2,5-dimethoxyaniline)-multi-wall carbon nanotubes doped with palladium telluride quantum dots onto a glassy carbon surface. The composite was assembled by a layer-by-layer method to form a multilayer film of quantum dots (QDs) and poly(2,5-dimethoxyaniline)- multi-wall carbon nanotubes (PDMA-MWCNT). Preparation of the electrochemical immunosensor for fumonisins involved drop-coating of fumonisins antibody onto the composite modified glassy carbon electrode. The electrochemical impedance spectroscopy response of the FB1 immunosensor (GCE/PT-PDMA-MWCNT/anti-Fms-BSA) gave a linear range of 7 to 49 ng L−1 and the corresponding sensitivity and detection limits were 0.0162 kΩ L ng−1 and 0.46 pg L−1 , respectively, hence the limit of detection of the GCE/PT-PDMA-MWCNT immunosensor for fumonisins in corn certified material was calculated to be 0.014 and 0.011 ppm for FB1, and FB2 and FB3, respectively. These results are lower than those obtained by ELISA, a provisional maximum tolerable daily intake (PMTDI) for fumonisins (the sum of FB1, FB2, and FB3) established by the Joint FAO/WHO expert committee on food additives and contaminants of 2 μg kg−1 and the maximum level recommended by the U.S. Food and Drug Administration (FDA) for protection of human consumption (2–4 mg L−1 )

    Determination of Anthracene on Ag-Au Alloy Nanoparticles/Overoxidized-Polypyrrole Composite Modified Glassy Carbon Electrodes

    Get PDF
    A novel electrochemical sensor for the detection of anthracene was prepared by modifying a glassy carbon electrode (GCE) with over-oxidized polypyrrole (PPyox) and Ag-Au (1:3) bimetallic nanoparticles (Ag-AuNPs). The composite electrode (PPyox/Ag-AuNPs/GCE) was prepared by potentiodynamic polymerization of pyrrole on GCE followed by its overoxidation in 0.1 M NaOH. Ag-Au bimetallic nanoparticles were chemically prepared by the reduction of AgNO3 and HAuCl4 using C6H5O7Na3 as the reducing agent as well as the capping agent and then immobilized on the surface of the PPyox/GCE. The nanoparticles were characterized by UV-visible spectroscopy technique which confirmed the homogeneous formation of the bimetallic alloy nanoparticles. Transmission electron microscopy showed that the synthesized bimetallic nanoparticles were in the range of 20–50 nm. The electrochemical behaviour of anthracene at the PPyox/Ag-AuNPs/GCE with Ag: Au atomic ratio 25:75 (1:3) exhibited a higher electrocatalytic effect compared to that observed when GCE was modified with each constituent of the composite (i.e., PPyox, Ag-AuNPs) and bare GCE. A linear relationship between anodic current and anthracene concentration was attained over the range of 3.0 × 10−6 to 3.56 × 10−4 M with a detection limit of 1.69 × 10−7 M. The proposed method was simple, less time consuming and showed a high sensitivity

    Implications for sequencing of biologic therapy and choice of second anti-TNF in patients with inflammatory bowel disease:results from the IMmunogenicity to Second Anti-TNF therapy (IMSAT) therapeutic drug monitoring study

    Get PDF
    BACKGROUND: Anti-drug antibodies are associated with treatment failure to anti-TNF agents in patients with inflammatory bowel disease (IBD).AIM: To assess whether immunogenicity to a patient's first anti-TNF agent would be associated with immunogenicity to the second, irrespective of drug sequence METHODS: We conducted a UK-wide, multicentre, retrospective cohort study to report rates of immunogenicity and treatment failure of second anti-TNF therapies in 1058 patients with IBD who underwent therapeutic drug monitoring for both infliximab and adalimumab. The primary outcome was immunogenicity to the second anti-TNF agent, defined at any timepoint as an anti-TNF antibody concentration ≥9 AU/ml for infliximab and ≥6 AU/ml for adalimumab.RESULTS: In patients treated with infliximab and then adalimumab, those who developed antibodies to infliximab were more likely to develop antibodies to adalimumab, than patients who did not develop antibodies to infliximab (OR 1.99, 95%CI 1.27-3.20, p = 0.002). Similarly, in patients treated with adalimumab and then infliximab, immunogenicity to adalimumab was associated with subsequent immunogenicity to infliximab (OR 2.63, 95%CI 1.46-4.80, p < 0.001). For each 10-fold increase in anti-infliximab and anti-adalimumab antibody concentration, the odds of subsequently developing antibodies to adalimumab and infliximab increased by 1.73 (95% CI 1.38-2.17, p < 0.001) and 1.99 (95%CI 1.34-2.99, p < 0.001), respectively. Patients who developed immunogenicity with undetectable drug levels to infliximab were more likely to develop immunogenicity with undetectable drug levels to adalimumab (OR 2.37, 95% CI 1.39-4.19, p < 0.001). Commencing an immunomodulator at the time of switching to the second anti-TNF was associated with improved drug persistence in patients with immunogenic, but not pharmacodynamic failure.CONCLUSION: Irrespective of drug sequence, immunogenicity to the first anti-TNF agent was associated with immunogenicity to the second, which was mitigated by the introduction of an immunomodulator in patients with immunogenic, but not pharmacodynamic treatment failure

    Implications for sequencing of biologic therapy and choice of second anti-TNF in patients with inflammatory bowel disease: results from the IMmunogenicity to Second Anti-TNF Therapy (IMSAT) therapeutic drug monitoring study

    Get PDF

    Implications for sequencing of biologic therapy and choice of second anti-TNF in patients with inflammatory bowel disease:results from the IMmunogenicity to Second Anti-TNF therapy (IMSAT) therapeutic drug monitoring study

    Get PDF
    BACKGROUND: Anti-drug antibodies are associated with treatment failure to anti-TNF agents in patients with inflammatory bowel disease (IBD).AIM: To assess whether immunogenicity to a patient's first anti-TNF agent would be associated with immunogenicity to the second, irrespective of drug sequence METHODS: We conducted a UK-wide, multicentre, retrospective cohort study to report rates of immunogenicity and treatment failure of second anti-TNF therapies in 1058 patients with IBD who underwent therapeutic drug monitoring for both infliximab and adalimumab. The primary outcome was immunogenicity to the second anti-TNF agent, defined at any timepoint as an anti-TNF antibody concentration ≥9 AU/ml for infliximab and ≥6 AU/ml for adalimumab.RESULTS: In patients treated with infliximab and then adalimumab, those who developed antibodies to infliximab were more likely to develop antibodies to adalimumab, than patients who did not develop antibodies to infliximab (OR 1.99, 95%CI 1.27-3.20, p = 0.002). Similarly, in patients treated with adalimumab and then infliximab, immunogenicity to adalimumab was associated with subsequent immunogenicity to infliximab (OR 2.63, 95%CI 1.46-4.80, p < 0.001). For each 10-fold increase in anti-infliximab and anti-adalimumab antibody concentration, the odds of subsequently developing antibodies to adalimumab and infliximab increased by 1.73 (95% CI 1.38-2.17, p < 0.001) and 1.99 (95%CI 1.34-2.99, p < 0.001), respectively. Patients who developed immunogenicity with undetectable drug levels to infliximab were more likely to develop immunogenicity with undetectable drug levels to adalimumab (OR 2.37, 95% CI 1.39-4.19, p < 0.001). Commencing an immunomodulator at the time of switching to the second anti-TNF was associated with improved drug persistence in patients with immunogenic, but not pharmacodynamic failure.CONCLUSION: Irrespective of drug sequence, immunogenicity to the first anti-TNF agent was associated with immunogenicity to the second, which was mitigated by the introduction of an immunomodulator in patients with immunogenic, but not pharmacodynamic treatment failure

    A year of genomic surveillance reveals how the SARS-CoV-2 pandemic unfolded in Africa

    Get PDF
    [Figure: see text]
    corecore