    Comparison of EBT and EBT3 RadioChromic Film Usage in Parotid Cancer Radiotherapy

    No full text
    Background: EBT and EBT3 radioChromic films have been used in radiotherapy dosimetry for years. Objective: The aim of the current study is to compare EBT and EBT3 radioChromic films in dosimetry of radiotherapy fields for treatment of parotid cancer. Methods: Calibrations of EBT and EBT3 films were performed with identical setups using a 6 MV photon beam of a Siemens Primus linac. Skin dose was measured at different points in the right anterior oblique (RAO) and right posterior oblique (RPO) fields by EBT and EBT3 films on a RANDO phantom. Results: While dosimetry was performed with the same conditions for the two film types for calibration and in phantom in parotid cancer radiotherapy, the measured net optical density (NOD) in EBT film was found to be higher than that from EBT3 film. The minimum difference between these two films under calibration conditions was about 2.9% (for 0.2 Gy) with a maximum difference of 35.5% (for 0.5 Gy). In the therapeutic fields of parotid cancer radiotherapy at different points, the measured dose from EBT film was higher than the EBT3 film. In these fields the minimum and maximum measured dose differences were 16.0% and 25.5%, respectively. Conclusion: EBT film demonstrates higher NOD than EBT3 film. This effect may be related to the higher sensitivity of EBT film over EBT3 film. However, the obtained dose differences between these two films in low dose range can be due to the differences in fitting functions applied following the calibration process

    Measurement of Thyroid Dose by TLD arising from Radiotherapy of Breast Cancer Patients from Supraclavicular Field

    No full text
    Background: Breast cancer is the most frequently diagnosed cancer and the leading global cause of cancer death among women worldwide. Radiotherapy plays a significant role in treatment of breast cancer and reduces locoregional recurrence and eventually improves survival. The treatment fields applied for breast cancer treatment include: tangential, axillary, supraclavicular and internal mammary fields. Objective: In the present study, due to the presence of sensitive organ such as thyroid inside the supraclavicular field, thyroid dose and its effective factors were investigated. Materials and Methods: Thyroid dose of 31 female patients of breast cancer with involved supraclavicular lymph nodes which had undergone radiotherapy were measured. For each patient, three TLD-100 chips were placed on their thyroid gland surface, and thyroid doses of patients were measured. The variables of the study include shield shape, the time of patientā€™s setup, the technologistsā€™ experience and qualification. Finally, the results were analyzed by ANOVA test using SPSS 11.5 software. Results: The average age of the patients was 46Ā±10 years. The average of thyroid dose of the patients was 140Ā±45 mGy (ranged 288.2 and 80.8) in single fraction. There was a significant relationship between the thyroid dose and shield shape. There was also a significant relationship between the thyroid dose and the patientā€™s setup time. Conclusion: Beside organ at risk such as thyroid which is in the supraclavicular field, thyroid dose possibility should be reduced. For solving this problem, an appropriate shield shape, the appropriate time of the patientā€™s setup, etc. could be considered

    Evaluation of micronuclei and antioxidant status in hospital radiation workers occupationally exposed to low-dose ionizing radiation

    No full text
    Abstract Purpose There is scientific evidence that ionizing radiation (IR) can be responsible for various health hazards that are one of the concerns in occupational exposure. This study was performed to evaluate DNA damage and antioxidant status in hospital workers who are occupationally exposed to low doses of IR. Materials and methods In this study, twenty occupationally exposed to low doses of IR (CT and angiography) comprising with control groups which matched them. In order to investigate the effects of chronic irradiation of radiation workers, Micronuclei (MN) frequency and the antioxidant activity of Superoxide Dismutase (SOD), Catalase (CAT) and Total Antioxidant Capacity (TAC) were measured. Then, to check adaptation against high challenge dose, the samples (in all groups) were irradiated in vitro and MN frequency was compared. Finally, to investigated the effect of the high dose after the acute and chronic low dose of ionizing radiation, MN frequency was compared in two groups (the control group that was to in-vitro irradiated (acute low doseā€‰+ā€‰high dose) and radiation workers (chronic low doseā€‰+ā€‰high dose)). Results MN frequency in the occupationally exposed group (nā€‰=ā€‰30) increased significantly when compared to the control group (p-valueā€‰ā€‰0.05). Conclusions We observed that exposure to low doses of IR leads to increased cytogenetic damage, could not cause an adaptive-response, and improve antioxidant capacity in radiation workers. Controlling healthcare workers' exposure is the first step to improving the health of hospital workers and the quality of patient care, thus decreasing human and economic costs

    In vivo study of interferon-?, transforming growth factor-ƃļæ½, and interleukin-4 gene expression induced by radioadaptive response

    Get PDF
    Introduction: In the present study, the radioadaptive role of the immune system induced by low dose (LD) was investigated for its in vivo protective activity. Materials and Methods: Quantitative analysis of cytokine gene expression was assessed for their in vivo activity in BALB/c mice. To evaluate the adaptive response induced by LD on the mice spleen lymphocyte, the cytokine interleukin (IL)-4, interferon (IFN)-?, and transforming growth factor (TGF)-ƃļæ½ expression was measured by a real-time quantitative polymerase chain reaction. To verify the radioadaptive effect of LD, animals were preirradiated at 10 cGy from a 60 Co source and then challenge dose at 200 cGy was delivered. Independent sample student's t-test was employed to compare cytokine gene expression in radioadaptive (10 + 200 cGy), LD (10 cGy), high-dose (HD, 200 cGy), and control groups of animals. Results: Following the HD, the cytokine gene expression of IFN-?, IL-4, and TGF-ƃļæ½ was significantly decreased compared to the control group (P = 0.0001). However, TGF-ƃļæ½ expression was also decreased significantly in the LD and adaptive groups compared to the control group (P = 0.0001). IFN-?/IL-4 ratio in the adaptive group was significantly decreased compared to the HD group (P = 0.0001). Conclusion: These results indicate that the immune system plays an important role for radioadaptive response induction by LD radiation to adjust the harmful effects of HD irradiation. ƂĀ© 2021 Journal of Cancer Research and Therapeutics | Published by Wolters Kluwer-Medknow

    The Dosimetric Impact of Implants on the Spinal Cord Dose During Stereotactic Body Radiotherapy

    Get PDF
    Background The effects of spinal implants on dose distribution have been studied for conformal treatment plans. However, the dosimetric impact of spinal implants in stereotactic body radiotherapy (SBRT) treatments has not been studied in spatial orientation. In this study we evaluated the effect of spinal implants placed in sawbone vertebra models implanted as in vivo instrumentations. Methods Four different spinal implant reconstruction techniques were performed using the standard sawbone lumbar vertebrae model; 1. L2-L4 posterior instrumentation without anterior column reconstruction (PI); 2. L2-L4 anterior instrumentation, L3 corpectomy, and anterior column reconstruction with a titanium cage (AIAC); 3. L2-L4 posterior instrumentation, L3 corpectomy, and anterior column reconstruction with a titanium cage (PIAC); 4. L2-L4 anterior instrumentation, L3 corpectomy, and anterior column reconstruction with chest tubes filled with bone cement (AIABc). The target was defined as the spinous process and lamina of the lumbar (L) 3 vertebra. A thermoluminescent dosimeter (TLD, LiF:Mg,Ti) was located on the measurement point anterior to the spinal cord. The prescription dose was 8Ā Gy and the treatment was administered in a single fraction using a CyberKnifeĀ® (Accuray Inc., Sunnyvale, CA, USA). We performed two different treatment plans. In Plan A beam interaction with the rod was not limited. In plan B the rod was considered a structure of avoidance, and interaction between the rod and beam was prevented. TLD measurements were compared with the point dose calculated by the treatment planning system (TPS). Results and discussion In plan A, the difference between TLD measurement and the dose calculated by the TPS was 1.7Ā %, 2.8Ā %, and 2.7Ā % for the sawbone with no implant, PI, and PIAC models, respectively. For the AIAC model the TLD dose was 13.8Ā % higher than the TPS dose; the difference was 18.6Ā % for the AIABc model. In plan B for the AIAC and AIABc models, TLD measurement was 2.5Ā % and 0.9Ā % higher than the dose calculated by the TPS, respectively. Conclusions Spinal implants may be present in the treatment field in patients scheduled to undergo SBRT. For the types of implants studied herein anterior rod instrumentation resulted in an increase in the spinal cord dose, whereas use of a titanium cage had a minimal effect on dose distribution. While planning SBRT in patients with spinal reconstructions, avoidance of the rod and preventing interaction between the rod and beam might be the optimal solution for preventing unexpectedly high spinal cord doses.PubMedWoSScopu