    Quality assurance program for prototype stereotactic system developed for Neptun 10 PC linac

    Get PDF
    Background: A prototype stereotactic radiosurgery set was designed and constructed for a Neptun 10 PC linac that is currently being used at Imam Reza hospital in Mashhad. Materials and Methods: A complete qualit y assurance program was designed and performed for the constructed system including isocentric accuracy test, localization accuracy test, dose delivery accuracy test and leakage radiation test. Target simulator, control alignment device and plexiglass phantom which were parts of the developed hardware were used to fulfill quality assurance program. Results: The average isocentric shift resulted from the gantry rotation and couch turning were respectively obtained to be 1.4 and 2 mm. The average localization error in the three coordinates was found to be 2.2 mm. The total treatment uncertainty due to all of the probable errors in the system was equal to 4.32 mm. The dose delivery accuracy test was carried out, the result indicated a 3-7% difference between the given and measured dose. Conclusion: The quality assurance tests showed consistent performance of the constructed system within the accepted limits; however, some inconsistency might exist in certain cases. The safety of SRS method is increased when the overall uncertainty is minimized and the treatment of the lesions adjacent to critical organs is avoided

    Analysis of Permanent Magnet Demagnetization Effect Outer-rotor Hybrid Excitation Flux Switching Motor

    Get PDF
    This paper addresses the irreversible permanent magnet (PM) demagnetization analysis of hybrid excitation flux switching motor (HEFSM) with outer-rotor configuration. PM demagnetization cause the PM strength used in the motor significantly reduces and hence contributes less torque performance. The study is focused on thermal analysis and conducted at various temperature up to as high as 180 degrees Celsius which has a tendency to be demagnetized. Therefore, PM demagnetization is among a critical issue and influences the choice of the applied motor. The analysis is carried out based on finite element method (FEM) and percentage of PM demagnetization is then calculated. Finally, based on simulated and calculated results the final design outer-rotor HEFSM has only 0.85 percent PM demagnetization at very high temperature and obviously the is no PM demagnetization at normal operating conditions
    corecore