585 research outputs found

    3D Residual Stress Field in Arteries: Novel Inverse Method Based on Optical Full-field Measurements

    Get PDF
    Arterial tissue consists of multiple structurally important constituents that have individual material properties and associated stress-free configurations that evolve over time. This gives rise to residual stresses contributing to the homoeostatic state of stress in vivo as well as adaptations to perturbed loads, disease or injury. The existence of residual stresses in an intact but load-free excised arterial segment suggests compressive and tensile stresses, respectively, in the inner and outer walls. Accordingly, an artery ring springs open into a sector after a radial cut. The measurement of the opening angle is commonly used to deduce the residual stresses, which are the stresses required to close back the ring. The opening angle method provides an average estimate of circumferential residual stresses but it gives no information on local distributions through the thickness and along the axial direction. To address this lack, a new method is proposed in this article to derive maps of residual stresses using an approach based on the contour method. A piece of freshly excised tissue is carefully cut into the specimen, and the local distribution of residual strains and stresses is determined from whole-body digital image correlation measurements using an inverse approach based on a finite element model

    Finite Element simulation of buckling-induced vein tortuosity and influence of the wall constitutive properties

    Get PDF
    International audienceThe mechanisms giving rise to vein tortuosity, which is often associated with varicosis, are poorly understood. Recent works suggest that significant biological changes in the wall of varicose veins may precede the mechanical aspects of the disease. To test the hypothesis of tortuosity being a consequence of these changes, a Finite Element model was developed based on previous experimental work on vein buckling. The model was then used to evaluate the effect of alterations of the mechanical behavior of the wall on tortuosity onset and severity. The results showed that increasing anisotropy toward the circumferential direction promotes tortuosity. An increase in wall stiffness tends to decrease the level of tortuosity but interestingly, if the vein segment is little or not pre-stretched such increase will not prevent, or it will even promote, the onset of tortuosity. These results provide additional arguments supporting the hypothesis of tortuosity being the consequence of biologically-induced changes in the varicose vein wall. Based on a 3D model of the leg and in vivo identification of the material properties of varicose veins, a clinical validation of these findings is being developed

    Anisotropic and hyperelastic identification of in vitro human arteries from full-field optical measurements

    Get PDF
    In this paper, we present a new approach for the bi-axial characterization of in vitro human arteries and we prove its feasibility on an example. The specificity of the approach is that it can handle heterogeneous strain and stress distributions in arterial segments. From the full-field experimental data obtained in inflation/extension tests, an inverse approach, called the virtual fields method (VFM), is used for deriving the material parameters of the tested arterial segment. The obtained results are promising and the approach can effectively provide relevant values for the anisotropic hyperelastic properties of the tested sample

    Identification des propriétés des tissus mous de la jambe sous compression élastique

    Get PDF
    National audienceLa compression élastique (CE) est largement utilisée pour le traitement et la prévention des insuffisances veineuses. Pour connaître la réponse des tissus internes à une pression externe, un modèle EF 3D d'une jambe humaine a été développé. Le modèle est constitué des tissus mous et des os dont les géométries sont obtenues à partir d'images scanner 3D. Une méthode inverse basée sur les images de la jambe avec et sans CE est utilisée pour identifier les propriétés des tissus mous. La méthode consiste à minimiser l'écart entre l'image de la jambe déformée par le modèle EF et l'image de la jambe sous CE

    Biomechanical response of varicose veins to elastic compression: A numerical study.

    Get PDF
    International audienceA patient-specific finite-element (FE) model of the human leg is developed to model the stress distribution in and around a vein wall in order to determine the biomechanical response of varicose veins to compression treatment. The aim is to investigate the relationship between the local pressure on the soft tissues induced by wearing the compression garment and the development and evolution of varicose veins and various skin-related diseases such as varicose veins and ulcers. Because experimental data on the mechanical properties of healthy superficial veins and varicose veins are scarce in literature, ultrasound images of in vivo varicose veins are acquired and analysed to extract the material constants using Finite Element Model Updating. The decrease in trans-mural pressure, which conditions the effectiveness of compressive treatments, is computed from the simulation results. This constitutes the original added value of the developed model as decrease in trans-mural pressures cannot be assessed experimentally by any other means. Results show that external compression is effective in decreasing the trans-mural pressure, thereby having a positive effect in the control and treatment of vein-related diseases

    Identification of the material parameters of soft tissues in the compressed leg

    Get PDF
    International audienceElastic compression (EC) is highly recommended in prophylaxis and treatment of venous disorder of the human leg. However, the exact mechanisms of its action are not enough understood and the response of internal tissues to the external pressure are still partially unknown. A 3D biomechanical FE model for simulating the effect of EC on the human leg has been developed based on the actual geometry of a female leg, obtained from 3D CT-scan images. The model is made up of soft tissues (fat and muscles) and rigid bones. A 2D FE model, reconstructed from MRI, is used to identify the elastic properties of soft tissues by an inverse method. The pressure applied by EC increases linearly from ankle to knee. The results show a non homogeneous pressure field (more than 35 % of discrepancies in a cross section of the leg) bringing evidence that the socks should be adapted to the diseased vein location

    Characterisation of failure in human aortic tissue using digital image correlation

    Get PDF
    International audienceAn aortic aneurism is a localized dilation of the aorta in a weakened area [1, 2]. The increase of aneurism size may result in rupture, which will be a life threatening emergency. The mechanism of failure in aneurysms is now relatively well understood. However, only limited research has provided quantitative values for the stresses that cause the failure of pathologic arterial tissue. The evaluation of the local failure stress remains an open problem. In this study we apply digital image correlation (DIC) to excised pieces of tissue that we test in a bulge inflation test. The tissue is taken from the ascending aorta in diseased patients requiring an excision for removing an aneurysm. All procedures are carried out in accordance with the guidelines of the Institutional Review Board of the University Hospital of Saint-Etienne, France

    Mechanical identification of hyperelastic anisotropic properties of mouse carotid arteries

    Get PDF
    International audienceThe role of mechanics is known to be of primary order in many arterial diseases; however determining mechanical properties of arteries remains a challenge. This paper discusses the identifiability of a Holzapfel-type material model for a mouse carotid artery, using an inverse method based on a finite element model and 3D digital image correlation measurements of the surface strain during an inflation/extension test. Layer-specific mean fiber angles are successfully determined using a five parameter constitutive model, demonstrating good robustness of the identification procedure. Importantly, we show that a model based on a single thick layer is unable to render the biaxial mechanical response of the artery tested here. On the contrary, difficulties related to the identification of a seven parameter constitutive model are evidenced; such a model leads to multiple solutions. Nevertheless, it is shown that an additional mechanical test, different in nature with the previous one, solves this proble

    Patient-specific simulation of stent-graft deployment within an abdominal aortic aneurysm

    Get PDF
    In this study, finite element analysis is used to simulate the surgical deployment procedure of a bifurcated stent-graft on a real patient's arterial geometry. The stent-graft is modeled using realistic constitutive properties for both the stent and most importantly for the graft. The arterial geometry is obtained from pre-operative imaging exam. The obtained results are in good agreement with the post-operative imaging data. As the whole computational time was reduced to less than 2 hours, this study constitutes an essential step towards predictive planning simulations of aneurysmal endovascular surger

    Mechanical characterization of the thoracic ascending aortae

    Get PDF
    International audienceIn this study the digital image correlation technique is used for characterizing the mechanical and fracture properties of aneurysmal tissues. The tissues which have been taken from the thoracic ascending aorta of diseased patients are tested in a bulge inflation test. The approach is original in the sense that it gives access to the local stress fields in the tissue and to local analysis of fracture. Applications to the dynamic behavior and fracture of vascular tissues are envisaged
    • …
    corecore