62 research outputs found

    Low-Noise Charge Preamplifier for Electrostatic Beam Position Monitoring Sensor at the ELENA Experiment

    Get PDF
    AbstractThe Extra Low ENergy Antiproton ring (ELENA) is a synchrotron under construction at CERN aimed to decelerate the antiprotons from the existing Antiproton Decelerator (AD) to an energy of 100 keV. The orbit measurement of the beam is accomplished by 20 electrostatic Beam Position Monitoring (BPM) sensors to measure complete orbits every 20ms with a resolution of 0.1mm for intensities in the range of 1-3×107 charges. For the conditioning of the pick-up signals from the BPMs a low-noise charge amplifier has been purposely designed and is under testing. The circuit must feature a bandwidth of 40MHz and an equivalent input voltage noise spectral density of 0.4 nV/√Hz for a sensor capacitance CS of about 26 pF. After amplification, the sum and difference signals are analogically derived and sent over 50 m cables to further blocks for digitalization and processing

    Optimization of an Impact-Based Frequency Up-Converted Piezoelectric Vibration Energy Harvester for Wearable Devices

    Get PDF
    This work presents a novel development of the impact-based mechanism for piezoelectric vibration energy harvesters. More precisely, the effect of an impacting mass on a cantilever piezoelectric transducer is studied both in terms of the tip mass value attached to the cantilever and impact position to find an optimal condition for power extraction. At first, the study is carried out by means of parametric analyses at varying tip mass and impact position on a unimorph MEMS cantilever, and a suitable physical interpretation of the associated electromechanical response is given. The effect of multiple impacts is also considered. From the analysis, it emerges that the most effective configuration, in terms of power output, is an impact at the cantilever tip without a tip mass. By changing the value of the tip mass, a sub-optimal impact position along the beam axis can also be identified. Moreover, the effect of a tip mass is deleterious on the power performance, contrary to the well-known case of a resonant energy harvester. A mesoscale prototype with a bimorph transducer is fabricated and tested to validate the computational models. The comparison shows a good agreement between numerical models and the experiments. The proposed approach is promising in the field of consumer electronics, such as wearable devices, in which the impact-based device moves at the frequencies of human movement and is much lower than those of microsystems

    The STRIP instrument of the Large Scale Polarization Explorer: microwave eyes to map the Galactic polarized foregrounds

    Get PDF
    In this paper we discuss the latest developments of the STRIP instrument of the "Large Scale Polarization Explorer" (LSPE) experiment. LSPE is a novel project that combines ground-based (STRIP) and balloon-borne (SWIPE) polarization measurements of the microwave sky on large angular scales to attempt a detection of the "B-modes" of the Cosmic Microwave Background polarization. STRIP will observe approximately 25% of the Northern sky from the "Observatorio del Teide" in Tenerife, using an array of forty-nine coherent polarimeters at 43 GHz, coupled to a 1.5 m fully rotating crossed-Dragone telescope. A second frequency channel with six-elements at 95 GHz will be exploited as an atmospheric monitor. At present, most of the hardware of the STRIP instrument has been developed and tested at sub-system level. System-level characterization, starting in July 2018, will lead STRIP to be shipped and installed at the observation site within the end of the year. The on-site verification and calibration of the whole instrument will prepare STRIP for a 2-years campaign for the observation of the CMB polarization.Comment: 17 pages, 15 figures, proceedings of the SPIE Astronomical Telescopes + Instrumentation conference "Millimeter, Submillimeter, and Far-Infrared Detectors and Instrumentation for Astronomy IX", on June 15th, 2018, Austin (TX

    Detection chain and electronic readout of the QUBIC instrument

    Get PDF
    The Q and U Bolometric Interferometer for Cosmology (QUBIC) Technical Demonstrator (TD) aiming to shows the feasibility of the combination of interferometry and bolometric detection. The electronic readout system is based on an array of 128 NbSi Transition Edge Sensors cooled at 350mK readout with 128 SQUIDs at 1K controlled and amplified by an Application Specific Integrated Circuit at 40K. This readout design allows a 128:1 Time Domain Multiplexing. We report the design and the performance of the detection chain in this paper. The technological demonstrator unwent a campaign of test in the lab. Evaluation of the QUBIC bolometers and readout electronics includes the measurement of I-V curves, time constant and the Noise Equivalent Power. Currently the mean Noise Equivalent Power is ~ 2 x 10⁻¹⁶ W/√Hz

    Detection chain and electronic readout of the QUBIC instrument

    Get PDF
    The Q and U Bolometric Interferometer for Cosmology (QUBIC) Technical Demonstrator (TD) aiming to shows the feasibility of the combination of interferometry and bolometric detection. The electronic readout system is based on an array of 128 NbSi Transition Edge Sensors cooled at 350mK readout with 128 SQUIDs at 1K controlled and amplified by an Application Specific Integrated Circuit at 40K. This readout design allows a 128:1 Time Domain Multiplexing. We report the design and the performance of the detection chain in this paper. The technological demonstrator unwent a campaign of test in the lab. Evaluation of the QUBIC bolometers and readout electronics includes the measurement of I-V curves, time constant and the Noise Equivalent Power. Currently the mean Noise Equivalent Power is ~ 2 x 10⁻¹⁶ W/√Hz

    Interview

    No full text

    Resonant Piezo-Layer (RPL) sensors with contactless interrogation for food monitoring from outside sealed packages

    Get PDF
    In this paper gravimetric resonant sensors interrogated as passive elements for monitoring relevant quantities in sealed food packages are presented. Resonant Piezo-Layers (RPL) devices are used as gravimetric sensors and contactless interrogated using a separation in time of the excitation and detection phases, exploiting the sensing of the resonator transient response. This technique is to first order independent on the interrogation distance and allows to measure physical or chemical quantities affecting the electromechanical resonant response of the sensor. A 6-MHz RPL sensor sensitized with Poly-Ethylhexyl-Acrylate (PEA) polymer has been successfully interrogated contactlessly from outside a sealed chamber to detect milk spoilage with operating distances of up to 20 mm

    Analysis and validation of contactless time-gated interrogation technique for quartz resonator sensors

    No full text
    A technique for contactless electromagnetic interrogation of AT-cut quartz piezoelectric resonator sensors is proposed based on a primary coil electromagnetically air-coupled to a secondary coil connected to the electrodes of the resonator. The interrogation technique periodically switches between interleaved excitation and detection phases. During the excitation phase, the resonator is set into vibration by a driving voltage applied to the primary coil, whereas in the detection phase, the excitation signal is turned off and the transient decaying response of the resonator is sensed without contact by measuring the voltage induced back across the primary coil. This approach ensures that the readout frequency of the sensor signal is to a first order approximation independent of the interrogation distance between the primary and secondary coils. A detailed theoretical analysis of the interrogation principle based on a lumped-element equivalent circuit is presented. The analysis has been experimentally validated on a 4.432 MHz AT-cut quartz crystal resonator, demonstrating the accurate readout of the series resonant frequency and quality factor over an interrogation distance of up to 2 cm. As an application, the technique has been applied to the measurement of liquid microdroplets deposited on a 4.8 MHz AT-cut quartz crystal. More generally, the proposed technique can be exploited for the measurement of any physical or chemical quantities affecting the resonant response of quartz resonator sensors

    Portable low-power system for one-lead ECG monitoring and datalogging

    No full text
    This work proposes a portable system for the measurement of ECG with a one-lead configuration for long term recording. The collected data are stored on high-density SD card for off-line examination. The present implementation focuses on low-power electronics to increase the battery lifetime, achieving about 16-h duration with two 158 mAh-capacity batteries. The system has proved to be able to detect heart rate anomalies on test subjects
    corecore