16 research outputs found

    Riboflavin/UVA Collagen Cross-Linking-Induced Changes in Normal and Keratoconus Corneal Stroma

    Get PDF
    Purpose To determine the effect of Ultraviolet-A collagen cross-linking with hypo-osmolar and iso-osmolar riboflavin solutions on stromal collagen ultrastructure in normal and keratoconus ex vivo human corneas. Methods Using small-angle X-ray scattering, measurements of collagen D-periodicity, fibril diameter and interfibrillar spacing were made at 1 mm intervals across six normal post-mortem corneas (two above physiological hydration (swollen) and four below (unswollen)) and two post-transplant keratoconus corneal buttons (one swollen; one unswollen), before and after hypo-osmolar cross-linking. The same parameters were measured in three other unswollen normal corneas before and after iso-osmolar cross-linking and in three pairs of swollen normal corneas, in which only the left was cross-linked (with iso-osmolar riboflavin). Results Hypo-osmolar cross-linking resulted in an increase in corneal hydration in all corneas. In the keratoconus corneas and unswollen normal corneas, this was accompanied by an increase in collagen interfibrillar spacing (p<0.001); an increase in fibril diameter was also seen in two out of four unswollen normal corneas and one unswollen keratoconus cornea (p<0.001). Iso-osmolar cross-linking resulted in a decrease in tissue hydration in the swollen normal corneas only. Although there was no consistent treatment-induced change in hydration in the unswollen normal samples, iso-osmolar cross-linking of these corneas did result in a compaction of collagen fibrils and a reduced fibril diameter (p<0.001); these changes were not seen in the swollen normal corneas. Collagen D-periodicity was not affected by either treatment. Conclusion The observed structural changes following Ultraviolet-A cross-linking with hypo-osmolar or iso-osmolar riboflavin solutions are more likely a consequence of treatment-induced changes in tissue hydration rather than cross-linking

    Transmural Mass Transfer in the Unsteady Microcirculation

    No full text

    The Relationship Between Cpap Usage And Corneal Thickness

    Get PDF
    The purpose of this study was to determine whether there is a correlation between CPAP usage and corneal thickness in patients with sleep disordered breathing. Full-night polysomnography (PSG) recordings were collected. Ten patients had undergone PSG recordings with continuous positive airway pressure (CPAP), and seven patients had undergone PSG recordings without CPAP. We measured corneal thickness by ultrasonic pachymeter before sleep and ten minutes after waking. We also measured visual acuity with a routine ophthalmologic eye chart before and after sleep. We asked patients to fill out a post-sleep questionnaire to get their subjective opinions. In the without-CPAP group, corneal thickness increased significantly during sleep in both eyes (left, p = 0.0025; right, p0.05 for both left and right cornea). There was no significant difference in visual acuity tests (p>0.05 for both left and right eye) between the two groups. According to our results, there is a significant increase in corneal thickness in the without-CPAP group. Our data show that a low percentage of Rapid Eye Movement (REM) sleep may cause an increase in corneal thickness, which can indicate poor corneal oxygenation. In fact, many sleep-disordered breathing (SDB) patients have low REM. Since a contact lens may cause low corneal oxygenation, SDB patients with contact lenses should be monitored carefully for their corneal thickness.PubMedWoSScopu
    corecore