11 research outputs found

    Universitas odontológica

    No full text
    Nerve injury secondary to trauma, neurological disease or tumor excision presents a challenge for surgical reconstruction. Current practice for nerve repair involves autologous nerve transplantation, which is associated with significant donor-site morbidity and other complications. Previously artificial nerve conduits made from polycaprolactone, polyglycolic acid and collagen were approved by the FDA (USA) for nerve repair. More recently, there have been significant advances in nerve conduit design that better address the requirements of nerve regrowth. Innovations in materials science, nanotechnology, and biology open the way for the synthesis of new generation nerve repair conduits that address issues currently faced in nerve repair and regeneration. This review discusses recent innovations in this area, including the use of nanotechnology to improve the design of nerve conduits and to enhance nerve regeneration

    In vivo biocompatibility of porous and non-porous polypyrrole based trilayered actuators

    Get PDF
    Trilayered polypyrrole (PPy) actuators have high stress density, low modulus and have wide potential biological applications including use in artificial muscles and in limb prosthesis after limb amputation. This article examines the in vivo biocompatibility of actuators in muscle using rabbit models. The actuators were specially designed with pores to encourage tissue in growth; this study also assessed the effect of such pores on the stability of the actuators in vivo. Trilayered PPy actuators were either laser cut with 150 µm pores or left pore-less and implanted into rabbit muscle for 3 days, 2 weeks, 4 weeks and 8 weeks and retrieved subsequently for histological analysis. In a second set of experiments, the cut edges of pores in porous actuator strips were further sealed by PPy after laser cutting to further improve its stability in vivo. Porous actuators with and without PPy sealing of pore edges were implanted intramuscularly for 4 and 8 weeks and assessed with histology. Pore-less actuators incited a mild inflammatory response, becoming progressively walled off by a thin layer of fibrous tissue. Porous actuators showed increased PPy fragmentation and delamination with associated greater foreign body response compared to pore-less actuators. The PPy fragmentation was minimized when the pore edges were sealed off by PPy after laser cutting showing less PPy debris. Laser cutting of the actuators with pores destabilizes the PPy. This can be overcome by sealing the cut edges of the pores with PPy after laser. The findings in this article have implications in future design and manufacturing of PPy actuator for use in vivo
    corecore