14 research outputs found

    Casting a Wide Net: HIV Drug Resistance Monitoring in Pre-Exposure Prophylaxis Seroconverters in the Global Evaluation of Microbicide Sensitivity Project

    Get PDF
    Background: Evidence of HIV drug resistance (HIVDR) in individuals using oral pre-exposure prophylaxis (PrEP) who acquire HIV is limited to clinical trials and case studies. More data are needed to understand the risk of HIVDR with oral PrEP during PrEP rollout. Mechanisms to collect these data vary, and are dependent on cost, scale of PrEP distribution, and in-country infrastructure for the identification, collection, and testing of samples from PrEP seroconverters. / Methods: The Global Evaluation of Microbicide Sensitivity (GEMS) project, in collaboration with country stakeholders, initiated HIVDR monitoring among new HIV seroconverters with prior PrEP use in Eswatini, Kenya, South Africa, and Zimbabwe. Standalone protocols were developed to assess HIVDR among a national sample of PrEP users. In addition, HIVDR testing was incorporated into existing demonstration projects for key populations. / Lessons learned: Countries are supportive of conducting a timelimited evaluation of HIVDR during the early stages of PrEP rollout. As PrEP rollout expands, the need for long-term HIVDR monitoring with PrEP will need to be balanced with maintaining national HIV drug resistance surveillance for pretreatment and acquired drug resistance. Laboratory capacity is a common obstacle to setting up a monitoring system. / Conclusions: Establishing HIV resistance monitoring within PrEP programs is feasible. Approaches to drug resistance monitoring may evolve as the PrEP programs mature and expand. The methods and implementation support offered by GEMS assisted countries in developing methods to monitor for drug resistance that best fit their PrEP program needs and resources

    Pet Project or Best Project? Online Decision Support Tools for Prioritizing Barrier Removals in the Great Lakes and Beyond

    Get PDF
    Structures that block movement of fish through river networks are built to serve a variety of societal needs, including transportation, hydroelectric power, and exclusion of exotic species. Due to their abundance, road crossings and dams reduce the amount of habitat available to fish that migrate from the sea or lakes into rivers to breed. The benefits to fish of removing any particular barrier depends on its location within the river network, its passability to fish, and the relative position of other barriers within the network. Balancing the trade-offs between ecological and societal values makes choosing among potential removal projects difficult. To facilitate prioritization of barrier removals, we developed an online decision support tool (DST) with three functions: (1) view existing barriers at various spatial scales; (2) modify information about barriers, including removal costs; and (3) run optimization models to identify portfolios of removals that provide the greatest amount of habitat access for a given budget. A survey of available DSTs addressing barrier removal prioritization indicates that barrier visualization is becoming widespread but few tools allow dynamic calculation of connectivity metrics, scenario analysis, or optimization. Having these additional functions, our DST enables organizations to develop barrier removal priorities based on cost-effectiveness in restoring aquatic connectivity

    Comparison of pregnancy incidence among African women in a randomized trial of intramuscular depot medroxyprogesterone acetate (DMPA-IM), a copper intrauterine device (IUDs) or a levonorgestrel (LNG) implant for contraception

    No full text
    OBJECTIVE: The objective was to address bias in contraception efficacy studies through a randomized study trial of intramuscular depot medroxyprogesterone acetate (DMPA-IM), a copper intrauterine device (IUDs) and a levonorgestrel (LNG) implant. STUDY DESIGN: We analyzed data from the Evidence for Contraceptive Options and HIV Outcomes Trial, which assessed HIV incidence among 7829 women from 12 sites in eSwatini, Kenya, South Africa and Zambia seeking effective contraception and who consented to be randomized to DMPA-IM, copper IUD or LNG implant. We used Cox proportional hazards regression adjusted for condom use to compare pregnancy incidence during both perfect and typical (i.e., allowing temporary interruptions) use. RESULTS: A total of 7710 women contributed to this analysis. Seventy pregnancies occurred during perfect and 85 during typical use. There was no statistically significant difference in perfect use pregnancy incidence among the methods: 0.61 per 100 woman-years for DMPA-IM [95% confidence interval (CI) 0.36–0.96], 1.06 for copper IUD (95% CI 0.72–1.50) and 0.63 for LNG implants (95% CI 0.39–0.96). Typical use pregnancy rates were also largely similar: 0.87 per 100 woman-years for DMPA-IM (95% CI 0.58–1.25), 1.11 for copper IUD (95% CI 0.77–1.54) and 0.63 for LNG implants (95% CI 0.39–0.96). CONCLUSIONS: In this randomized trial of highly effective contraceptive methods among African women, both perfect and typical use resulted in low pregnancy rates. Our findings provide strong justification for improving access to a broader range of longer-acting contraceptive options including LNG implants and copper IUD for African women.The Bill & Melinda Gates Foundation, the United States Agency for International Development, the Swedish International Development Cooperation Agency as part of the EDCTP2 program supported by the European Union, the South African Medical Research Council and the United Nations Population Fund. Contraceptive supplies were donated by the Government of South Africa and United States Agency for International Development.https://www.journals.elsevier.com/conxpm2021Family Medicin

    Helium adsorbed on carbon nanotube bundles: one-dimensional and/or two-dimensional solids?

    No full text
    Heat capacity measurements of ⁴He adsorbed on closed-end single-wall carbon nanotube bundles in the temperature range 1.5 K < T < 6 K are reported. Heats of adsorption Qst calculated from isotherms measured on the same calorimeter cell are included. We correlate Qst features with features of the helium heat capacity. We discuss possible interpretations of the current data

    Use of Adeno-Associated Virus as a General Transduction Vector for Mammalian Cells

    No full text
    corecore