11 research outputs found

    Atmospheric stilling offsets the benefits from reduced nutrient loading in a large shallow lake

    Get PDF
    As part of a global phenomenon, a 30% decrease in average wind speed since 1996 in southern Estonia together with more frequent easterly winds resulted in 47% decrease in bottom shear stress in the large (270 km2), shallow (mean depth 2.8 m), and eutrophic Lake VĂ”rtsjĂ€rv. Following a peak in eutrophication pressure in the 1970s–80s, the concentrations of total nutrients were declining. Nonmetric Multidimensional Scaling (NMDS) ordination of a 54-year phytoplankton community composition time-series (1964–2017) revealed three distinct periods with breaking points coinciding with changes in wind and/or water level. Contrary to expectations, we detected no decrease in optically active substances that could be related to wind stilling, whereas phytoplankton biomass showed an increasing trend despite reduced nutrient levels. Here we show how opening of the “light niche,” caused by declining amount of suspended sediments, was capitalized and filled by the light-limited phytoplankton community. We suggest that wind stilling is another global factor, complementary to climate warming that counteracts eutrophication mitigation in lakes and may provide a challenge to assessment of the lake ecological status.Main financial support for EMU: European Union’s Horizon 2020 research and innovation programme Under the Marie SkƂodowska-Curie Action, Innovative Training Networks, European Joint Doctorates.Project name, acronym and grant number: Management of climatic extreme events in lakes and reservoirs for the protection of ecosystem services, MANTEL, grant agreement No 722518.Publication date and, if applicable, length of embargo period: Published as Early View on 07.10.2019, no embargo period.Main financial support for EMU: European Union’s Horizon 2020 research and innovation programme Under the Marie SkƂodowska-Curie Action, Innovative Training Networks, European Joint Doctorate

    Field Intercomparison of Radiometers Used for Satellite Validation in the 400–900 nm Range

    Get PDF
    An intercomparison of radiance and irradiance ocean color radiometers (the second laboratory comparison exercise—LCE-2) was organized within the frame of the European Space Agency funded project Fiducial Reference Measurements for Satellite Ocean Color (FRM4SOC) May 8–13, 2017 at Tartu Observatory, Estonia. LCE-2 consisted of three sub-tasks: (1) SI-traceable radiometric calibration of all the participating radiance and irradiance radiometers at the Tartu Observatory just before the comparisons; (2) indoor, laboratory intercomparison using stable radiance and irradiance sources in a controlled environment; (3) outdoor, field intercomparison of natural radiation sources over a natural water surface. The aim of the experiment was to provide a link in the chain of traceability from field measurements of water reflectance to the uniform SI-traceable calibration, and after calibration to verify whether different instruments measuring the same object provide results consistent within the expected uncertainty limits. This paper describes the third phase of LCE-2: The results of the field experiment. The calibration of radiometers and laboratory comparison experiment are presented in a related paper of the same journal issue. Compared to the laboratory comparison, the field intercomparison has demonstrated substantially larger variability between freshly calibrated sensors, because the targets and environmental conditions during radiometric calibration were different, both spectrally and spatially. Major differences were found for radiance sensors measuring a sunlit water target at viewing zenith angle of 139° because of the different fields of view. Major differences were found for irradiance sensors because of imperfect cosine response of diffusers. Variability between individual radiometers did depend significantly also on the type of the sensor and on the specific measurement target. Uniform SI traceable radiometric calibration ensuring fairly good consistency for indoor, laboratory measurements is insufficient for outdoor, field measurements, mainly due to the different angular variability of illumination. More stringent specifications and individual testing of radiometers for all relevant systematic effects (temperature, nonlinearity, spectral stray light, etc.) are needed to reduce biases between instruments and better quantify measurement uncertainties

    Laboratory Intercomparison of Radiometers Used for Satellite Validation in the 400–900 nm Range

    Get PDF
    An intercomparison of radiance and irradiance ocean color radiometers (The Second Laboratory Comparison Exercise—LCE-2) was organized within the frame of the European Space Agency funded project Fiducial Reference Measurements for Satellite Ocean Color (FRM4SOC) May 8–13, 2017 at Tartu Observatory, Estonia. LCE-2 consisted of three sub-tasks: 1) SI-traceable radiometric calibration of all the participating radiance and irradiance radiometers at the Tartu Observatory just before the comparisons; 2) Indoor intercomparison using stable radiance and irradiance sources in controlled environment; and 3) Outdoor intercomparison of natural radiation sources over terrestrial water surface. The aim of the experiment was to provide one link in the chain of traceability from field measurements of water reflectance to the uniform SI-traceable calibration, and after calibration to verify whether different instruments measuring the same object provide results consistent within the expected uncertainty limits. This paper describes the activities and results of the first two phases of LCE-2: the SI-traceable radiometric calibration and indoor intercomparison, the results of outdoor experiment are presented in a related paper of the same journal issue. The indoor experiment of the LCE-2 has proven that uniform calibration just before the use of radiometers is highly effective. Distinct radiometers from different manufacturers operated by different scientists can yield quite close radiance and irradiance results (standard deviation s < 1%) under defined conditions. This holds when measuring stable lamp-based targets under stationary laboratory conditions with all the radiometers uniformly calibrated against the same standards just prior to the experiment. In addition, some unification of measurement and data processing must be settled. Uncertainty of radiance and irradiance measurement under these conditions largely consists of the sensor’s calibration uncertainty and of the spread of results obtained by individual sensors measuring the same object

    REMOTE SENSING OF WATER QUALITY IN OPTICALLY COMPLEX LAKES

    No full text
    Solving of several global and regional problems requires adequate data about lake water quality parameters like the amount and type of phytoplankton dominating in the lakes, the amount of dissolved and coloured dissolved organic matter and/or concentration of suspended sediment. Remote sensing is the only practical way to study many lakes provided it can produce sufficiently accurate estimates of the water characteristics. We studied optically very variable lakes in order to test both physics based methods and conventional band-ratio type algorithms in retrieval of water parameters. The modelled spectral library used in the physics based approach provided very good results for chlorophyll-a retrieval. The number of different concentrations of CDOM and suspended matter used in the simulations was too low to provide good estimates of these parameters. Extending the spectral library is currently in progress. Band-ratio type algorithms worked well in chlorophyll-a and CDOM retrieval. None of the algorithms tested for total suspended matter, organic suspended matter and inorganic suspended matter retrieval performed well enough and there is need in further testing

    The specific inherent optical properties of three sub-tropical and tropical water reservoirs in Queensland, Australia

    Get PDF
    The underwater light climate, which is a major influence on the ecology of aquatic systems, is affected by the absorption and scattering processes that take place within the water column. Knowledge of the Specific Inherent Optical Properties (SIOPs) of water quality parameters and their spatial variation is essential for the modelling of underwater light fields and remote sensing applications. We measured the SIOPs and water quality parameter concentrations of three large inland water impoundments in Queensland, Australia. The measurements ranged from 0.9–42.7 ÎŒgl/1 for chlorophyll a concentration, 0.9–170.4 mgl/1 for tripton concentration, 0.36–1.59 m/1 for aCDOM(440) and 0.15–2.5 m for Secchi depth. The SIOP measurements showed that there is sufficient intra-impoundment variation in the specific absorption and specific scattering of phytoplankton and tripton to require a well distributed network of measurement stations to fully characterise the SIOPs of the optical water quality parameters. While significantly different SIOP sets were measured for each of the study sites the measurements were consistent with published values in other inland waters. The multiple measurement stations were allocated into optical domains as a necessary step to parameterise a semi-analytical inversion remote sensing algorithm. This paper also addresses the paucity of published global inland water SIOP sets by contributing Australian SIOP sets to allow international and national comparison

    General anaesthesia versus local anaesthesia for carotid surgery (GALA): a multicentre, randomised controlled trial

    No full text
    Background: The effect of carotid endarterectomy in lowering the risk of stroke ipsilateral to severe atherosclerotic carotid-artery stenosis is offset by complications during or soon after surgery. We compared surgery under general anaesthesia with that under local anaesthesia because prediction and avoidance of perioperative strokes might be easier under local anaesthesia than under general anaesthesia. Methods: We undertook a parallel group, multicentre, randomised controlled trial of 3526 patients with symptomatic or asymptomatic carotid stenosis from 95 centres in 24 countries. Participants were randomly assigned to surgery under general (n=1753) or local (n=1773) anaesthesia between June, 1999 and October, 2007. The primary outcome was the proportion of patients with stroke (including retinal infarction), myocardial infarction, or death between randomisation and 30 days after surgery. Analysis was by intention to treat. The trial is registered with Current Control Trials number ISRCTN00525237. Findings: A primary outcome occurred in 84 (4·8%) patients assigned to surgery under general anaesthesia and 80 (4·5%) of those assigned to surgery under local anaesthesia; three events per 1000 treated were prevented with local anaesthesia (95% CI -11 to 17; risk ratio [RR] 0·94 [95% CI 0·70 to 1·27]). The two groups did not significantly differ for quality of life, length of hospital stay, or the primary outcome in the prespecified subgroups of age, contralateral carotid occlusion, and baseline surgical risk. Interpretation: We have not shown a definite difference in outcomes between general and local anaesthesia for carotid surgery. The anaesthetist and surgeon, in consultation with the patient, should decide which anaesthetic technique to use on an individual basis. Funding: The Health Foundation (UK) and European Society of Vascular Surgery. © 2008 Elsevier Ltd. All rights reserved
    corecore