761 research outputs found
Stress-Induced Variations in the Stiffness of Micro- and Nanocantilever Beams
The effect of surface stress on the stiffness of cantilever beams remains an outstanding problem in the physical sciences. While numerous experimental studies report significant stiffness change due to surface stress, theoretical predictions are unable to rigorously and quantitatively reconcile these observations. In
this Letter, we present the first controlled measurements of stress-induced change in cantilever stiffness with commensurate theoretical quantification. Simultaneous measurements are also performed on equivalent clamped-clamped beams. All experimental results are quantitatively and accurately predicted using elasticity theory. We also present conclusive experimental evidence for invalidity of the longstanding and unphysical axial force model, which has been widely applied to interpret measurements using cantilever beams. Our findings will be of value in the development of micro- and nanoscale resonant mechanical sensors
A Nanoscale Parametric Feedback Oscillator
We describe and demonstrate a new oscillator topology, the parametric feedback oscillator (PFO). The PFO paradigm is applicable to a wide variety of nanoscale devices and opens the possibility of new classes of oscillators employing innovative frequency-determining elements, such as nanoelectromechanical systems (NEMS), facilitating integration with circuitry and system-size reduction. We show that the PFO topology can also improve nanoscale oscillator performance by circumventing detrimental effects that are otherwise imposed by the strong device nonlinearity in this size regime
Signal Amplification by Sensitive Control of Bifurcation Topology
We describe a novel amplification scheme based on inducing dynamical changes to the topology of a bifurcation diagram of a simple nonlinear dynamical system. We have implemented a first bifurcation-topology amplifier using a coupled pair of parametrically driven high-frequency nanoelectromechanical systems resonators, demonstrating robust small-signal amplification. The principles that underlie bifurcation-topology amplification are simple and generic, suggesting its applicability to a wide variety of physical, chemical, and biological systems
Piezoelectric nanoelectromechanical resonators based on aluminum nitride thin films
We demonstrate piezoelectrically actuated, electrically tunable nanomechanical resonators based on multilayers containing a 100-nm-thin aluminum nitride (AlN) layer. Efficient piezoelectric actuation of very high frequency fundamental flexural modes up to ~80 MHz is demonstrated at room temperature. Thermomechanical fluctuations of AlN cantilevers measured by optical interferometry enable calibration of the transduction responsivity and displacement sensitivities of the resonators. Measurements and analyses show that the 100 nm AlN layer employed has an excellent piezoelectric coefficient, d_(31)=2.4 pm/V. Doubly clamped AlN beams exhibit significant frequency tuning behavior with applied dc voltage
A Passive Phase Noise Cancellation Element
We introduce a new method for reducing phase noise in oscillators, thereby
improving their frequency precision. The noise reduction device consists of a
pair of coupled nonlinear resonating elements that are driven parametrically by
the output of a conventional oscillator at a frequency close to the sum of the
linear mode frequencies. Above the threshold for parametric response, the
coupled resonators exhibit self-oscillation at an inherent frequency. We find
operating points of the device for which this periodic signal is immune to
frequency noise in the driving oscillator, providing a way to clean its phase
noise. We present results for the effect of thermal noise to advance a broader
understanding of the overall noise sensitivity and the fundamental operating
limits
Surpassing Fundamental Limits of Oscillators Using Nonlinear Resonators
In its most basic form an oscillator consists of a resonator driven on resonance, through feedback, to create a periodic signal sustained by a static energy source. The generation of a stable frequency, the basic function of oscillators, is typically achieved by increasing the amplitude of motion of the resonator while remaining within its linear, harmonic regime. Contrary to this conventional paradigm, in this Letter we show that by operating the oscillator at special points in the resonator’s anharmonic regime we can overcome fundamental limitations of oscillator performance due to thermodynamic noise as well as practical limitations due to noise from the sustaining circuit. We develop a comprehensive model that accounts for the major contributions to the phase noise of the nonlinear oscillator. Using a nanoelectromechanical system based oscillator, we experimentally verify the existence of a special region in the operational parameter space that enables suppressing the most significant contributions to the oscillator’s phase noise, as predicted by our model
The Building Blocks of Interoperability. A Multisite Analysis of Patient Demographic Attributes Available for Matching.
BackgroundPatient matching is a key barrier to achieving interoperability. Patient demographic elements must be consistently collected over time and region to be valuable elements for patient matching.ObjectivesWe sought to determine what patient demographic attributes are collected at multiple institutions in the United States and see how their availability changes over time and across clinical sites.MethodsWe compiled a list of 36 demographic elements that stakeholders previously identified as essential patient demographic attributes that should be collected for the purpose of linking patient records. We studied a convenience sample of 9 health care systems from geographically distinct sites around the country. We identified changes in the availability of individual patient demographic attributes over time and across clinical sites.ResultsSeveral attributes were consistently available over the study period (2005-2014) including last name (99.96%), first name (99.95%), date of birth (98.82%), gender/sex (99.73%), postal code (94.71%), and full street address (94.65%). Other attributes changed significantly from 2005-2014: Social security number (SSN) availability declined from 83.3% to 50.44% (p<0.0001). Email address availability increased from 8.94% up to 54% availability (p<0.0001). Work phone number increased from 20.61% to 52.33% (p<0.0001).ConclusionsOverall, first name, last name, date of birth, gender/sex and address were widely collected across institutional sites and over time. Availability of emerging attributes such as email and phone numbers are increasing while SSN use is declining. Understanding the relative availability of patient attributes can inform strategies for optimal matching in healthcare
Nonlinearity in nanomechanical cantilevers
Euler-Bernoulli beam theory is widely used to successfully predict the linear dynamics of micro- and nanocantilever beams. However, its capacity to characterize the nonlinear dynamics of these devices has not yet been rigorously assessed, despite its use in nanoelectromechanical systems development. In this article, we report the first highly controlled measurements of the nonlinear response of nanomechanical cantilevers using an ultralinear detection system. This is performed for an extensive range of devices to probe the validity of Euler-Bernoulli theory in the nonlinear regime. We find that its predictions deviate strongly from our measurements for the nonlinearity of the fundamental flexural mode, which show a systematic dependence on aspect ratio (length/width) together with random scatter. This contrasts with the second mode, which is always found to be in good agreement with theory. These findings underscore the delicate balance between inertial and geometric nonlinear effects in the fundamental mode, and strongly motivate further work to develop theories beyond the Euler-Bernoulli approximation
The Green Bank Northern Celestial Cap Pulsar Survey II: The Discovery and Timing of Ten Pulsars
We present timing solutions for ten pulsars discovered in 350 MHz searches
with the Green Bank Telescope. Nine of these were discovered in the Green Bank
Northern Celestial Cap survey and one was discovered by students in the Pulsar
Search Collaboratory program in analysis of drift-scan data. Following
discovery and confirmation with the Green Bank Telescope, timing has yielded
phase-connected solutions with high precision measurements of rotational and
astrometric parameters. Eight of the pulsars are slow and isolated, including
PSR J09302301, a pulsar with nulling fraction lower limit of 30\% and
nulling timescale of seconds to minutes. This pulsar also shows evidence of
mode changing. The remaining two pulsars have undergone recycling, accreting
material from binary companions, resulting in higher spin frequencies. PSR
J05572948 is an isolated, 44 \rm{ms} pulsar that has been partially recycled
and is likely a former member of a binary system which was disrupted by a
second supernova. The paucity of such so-called `disrupted binary pulsars'
(DRPs) compared to double neutron star (DNS) binaries can be used to test
current evolutionary scenarios, especially the kicks imparted on the neutron
stars in the second supernova. There is some evidence that DRPs have larger
space velocities, which could explain their small numbers. PSR J1806+2819 is a
15 \rm{ms} pulsar in a 44 day orbit with a low mass white dwarf companion. We
did not detect the companion in archival optical data, indicating that it must
be older than 1200 Myr.Comment: 9 pages, 5 figure
- …
