8 research outputs found

    Dynamic 3D shape of the plantar surface of the foot using coded structured light:a technical report

    Get PDF
    The foot provides a crucial contribution to the balance and stability of the musculoskeletal system, and accurate foot measurements are important in applications such as designing custom insoles/footwear. With better understanding of the dynamic behavior of the foot, dynamic foot reconstruction techniques are surfacing as useful ways to properly measure the shape of the foot. This paper presents a novel design and implementation of a structured-light prototype system providing dense three dimensional (3D) measurements of the foot in motion. The input to the system is a video sequence of a foot during a single step; the output is a 3D reconstruction of the plantar surface of the foot for each frame of the input. Methods Engineering and clinical tests were carried out to test the accuracy and repeatability of the system. Accuracy experiments involved imaging a planar surface from different orientations and elevations and measuring the fitting errors of the data to a plane. Repeatability experiments were done using reconstructions from 27 different subjects, where for each one both right and left feet were reconstructed in static and dynamic conditions over two different days. Results The static accuracy of the system was found to be 0.3 mm with planar test objects. In tests with real feet, the system proved repeatable, with reconstruction differences between trials one week apart averaging 2.4 mm (static case) and 2.8 mm (dynamic case). Conclusion The results obtained in the experiments show positive accuracy and repeatability results when compared to current literature. The design also shows to be superior to the systems available in the literature in several factors. Further studies need to be done to quantify the reliability of the system in clinical environment

    Intensive post-operative follow-up of breast cancer patients with tumour markers: CEA, TPA or CA15.3 vs MCA and MCA-CA15.3 vs CEA-TPA-CA15.3 panel in the early detection of distant metastases

    Get PDF
    BACKGROUND: In breast cancer current guidelines do not recommend the routine use of serum tumour markers. Differently, we observed that CEA-TPA-CA15.3 (carcinoembryonic (CEA) tissue polypeptide (TPA) and cancer associated 115D8/DF3 (CA15.3) antigens) panel permits early detection and treatment for most relapsing patients. As high sensitivity and specificity and different cut-off values have been reported for mucin-like carcinoma associated antigen (MCA), we compared MCA with the above mentioned tumour markers and MCA-CA15.3 with the CEA-TPA-CA15.3 panel. METHODS: In 289 breast cancer patients submitted to an intensive post-operative follow-up with tumour markers, we compared MCA (cut-off values, ≥ 11 and ≥ 15 U/mL) with CEA or CA15.3 or TPA for detection of relapse. In addition, we compared the MCA-CA15.3 and CEA-TPA-CA15.3 tumour marker panels. RESULTS: Distant metastases occurred 19 times in 18 (6.7%) of the 268 patients who were disease-free at the beginning of the study. MCA sensitivity with both cut-off values was higher than that of CEA or TPA or CA15.3 (68% vs 10%, 26%, 32% and 53% vs 16%, 42%, 32% respectively). With cut-off ≥ 11 U/mL, MCA showed the lowest specificity (42%); with cut-off ≥ 15 U/mL, MCA specificity was similar to TPA (73% vs 72%) and lower than that of CEA and CA15.3 (96% and 97% respectively). With ≥ 15 U/mL MCA cut-off, MCA sensitivity increased from 53% to 58% after its association with CA15.3. Sensitivity of CEA-TPA-CA15.3 panel was 74% (14 of 19 recurrences). Eight of the 14 recurrences early detected with CEA-TPA-CA15.3 presented as a single lesion (oligometastatic disease) (5) or were confined to bony skeleton (3) (26% and 16% respectively of the 19 relapses). With ≥ 11 U/mL MCA cut-off, MCA-CA15.3 association showed higher sensitivity but lower specificity, accuracy and positive predictive value than the CEA-TPA-CA15.3 panel. CONCLUSION: At both the evaluated cut-off values serum MCA sensitivity is higher than that of CEA, TPA or CA15.3 but its specificity is similar to or lower than that of TPA. Overall, CEA-TPA-CA15.3 panel is more accurate than MCA-CA15.3 association and can "early" detect a few relapsed patients with limited metastatic disease and more favourable prognosis. These findings further support the need for prospective randomised clinical trial to assess whether an intensive post-operative follow-up with an appropriate use of serum tumour markers can significantly improve clinical outcome of early detected relapsing patients

    An investigation into the facilitative effects of two kinds of adjunct questions on the learning and remembering of teachers' college students during the reading of textual materials with an associated study of student reading improvement incorporating a survey of their textbook reading habits, attitudes and problems.

    Get PDF