    Application of polarization ellipse technique for analysis of ULF magnetic fields from two distant stations in Koyna-Warna seismoactive region, West India

    Get PDF
    A new approach is developed to find the source azimuth of the ultra low frequency (ULF) electromagnetic (EM) signals believed to be emanating from well defined seismic zone. The method is test applied on magnetic data procured from the seismoactive region of Koyna-Warna, known for prolonged reservoir triggered seismicity. Extremely low-noise, high-sensitivity LEMI-30 search coil magnetometers were used to measure simultaneously the vector magnetic field in the frequency range 0.001–32 Hz at two stations, the one located within and another ~100 km away from the seismic active zone. During the observation campaign extending from 15 March to 30 June 2006 two earthquakes (EQs) of magnitude (M<sub><I>L</I></sub>>4) occurred, which are searched for the presence of precursory EM signals. <br><br> Comparison of polarization ellipses (PE) parameters formed by the magnetic field components at the measurement stations, in select frequency bands, allows discrimination of seismo-EM signals from the natural background ULF signals of magnetospheric/ionospheric origin. The magnetic field components corresponding to spectral bands dominated by seismo-EM fields define the PE plane which at any instant contains the source of the EM fields. Intersection lines of such defined PE planes for distant observation stations clutter in to the source region. Approximating the magnetic-dipole configuration for the source, the magnetic field components along the intersection lines suggest that azimuth of the EM source align in the NNW-SSE direction. This direction well coincides with the orientation of nodal plane of normal fault plane mechanism for the two largest EQs recorded during the campaign. More significantly the correspondence of this direction with the tectonic controlled trend in local seismicity, it has been surmised that high pressure fluid flow along the fault that facilitate EQs in the region may also be the source mechanism for EM fields by electrokinetic effect

    Neutron influences and energy spectra in the Cosmos-2044 biosatellite orbit

    Get PDF
    Joint Soviet-American measurements of the neutron component of space radiation (SR) were carried out during the flight of the Soviet biosatellite Cosmos-2044. Neutron flux densities and differential energy spectra were measured inside and on the external surface of the spacecraft. Three energy intervals were employed: thermal (E(sub n) less than or equal to 0.2 eV), resonance (0.2 eV less than E(sub n) less than 1.0 MeV) and fast (E(sub n) greater than or equal to 1.0 MeV) neutrons. The first two groups were measured with U.S. (6)LiF detectors, while fast neutrons were recorded both by U.S. fission foils and Soviet nuclear emulsions. Estimations were made of the contributions to absorbed and equivalent doses from each neutron energy interval and a correlation was presented between fast neutron fluxes, measured outside the satellite, and the phase of solar activity (SA). Average dose equivalent rates of 0.018 and 0.14 mrem d(exp -1) were measured for thermal and resonance neutrons, respectively, outside the spacecraft. The corresponding values for fast neutrons were 3.3 (U.S.) and 1.8 (U.S.S.R.) mrem d(exp -1). Inside the spacecraft, a value of 3.5 mrem d(exp -1) was found

    Differential neutron energy spectra measured on spacecraft low Earth orbit

    Get PDF
    Two methods for measuring neutrons in the range from thermal energies to dozens of MeV were used. In the first method, alpha-particles emitted from the (sup 6) Li(n.x)T reaction are detected with the help of plastic nuclear track detectors, yielding results on thermal and resonance neutrons. Also, fission foils are used to detect fast neutrons. In the second method, fast neutrons are recorded by nuclear photographic emulsions (NPE). The results of measurements on board various satellites are presented. The neutron flux density does not appear to correlate clearly with orbital parameters. Up to 50% of neutrons are due to albedo neutrons from the atmosphere while the fluxes inside the satellites are 15-20% higher than those on the outside. Estimates show that the neutron contribution to the total equivalent radiation dose reaches 20-30%

    Generation of neutrons in a nanosecond low-pressure discharge in deuterium

    Get PDF
    The neutron yield is measured in a high-voltage Townsend discharge in deuterium with a hollow cylinder made of tungsten or steel used as a polarizing anode of electrons. A flat metallic plate covered by a layer of deuterated zirconium is applied as a grounded cathode. The highest yield of neutrons in the reaction 2H(d,n)3He, ∼1.2 × 104 neutrons per pulse, is observed in the case of the tungsten anode at a deuterium pressure on the order of 100 Pa. The pulsed neutron flux duration estimated with data obtained from a scintillation detector is roughly equal to 1.5 ns

    Characteristics of alpha projectile fragments emission in interaction of nuclei with emulsion

    Full text link
    The properties of the relativistic alpha fragments produced in interactions of 84^Kr at around 1 A GeV in nuclear emulsion are investigated. The experimental results are compared with the similar results obtained from various projectiles with emulsion interactions at different energies. The total, partial nuclear cross-sections and production rates of alpha fragmentation channels in relativistic nucleus-nucleus collisions and their dependence on the mass number and initial energy of the incident projectile nucleus are investigated. The yields of multiple alpha fragments emitted from the interactions of projectile nuclei with the nuclei of light, medium and heavy target groups of emulsion-detector are discussed and they indicate that the projectile-breakup mechanism seems to be free from the target mass number. It is found that the multiplicity distributions of alpha fragments are well described by the Koba-Nielsen-Olesen (KNO) scaling presentation. The mean multiplicities of the freshly produced newly created charged secondary particles, normally known as shower and secondary particles associated with target in the events where the emission of alpha fragments were accompanied by heavy projectile fragments having Z value larger than 4 seem to be constant as the alpha fragments multiplicity increases, and exhibit a behavior independent of the alpha fragments multiplicity.Comment: 33 pages, 8 figures and 3 tables (in press

    Linear Energy Transfer (LET) spectra of cosmic radiation in low Earth orbit

    Get PDF
    Integral linear energy transfer (LET) spectra of cosmic radiation (CR) particles were measured on five Cosmos series spacecraft in low Earth orbit (LEO). Particular emphasis is placed on results of the Cosmos 1887 biosatellite which carried a set of joint U.S.S.R.-U.S.A. radiation experiments involving passive detectors that included thermoluminescent detectors (TLD's), plastic nuclear track detectors (PNTD's), fission foils, nuclear photo-emulsions, etc. which were located both inside and outside the spacecraft. Measured LET spectra are compared with those theoretically calculated. Results show that there is some dependence of LET spectra on orbital parameters. The results are used to estimate the CR quality factor (QF) for the COSMOS 1887 mission

    Experimental research of neutron yield and spectrum from deuterium gas-puff z-pinch on the GIT-12 generator at current above 2 MA

    Get PDF
    The Z-pinch experiments with deuterium gas-puff surrounded by an outer plasma shell were carried out on the GIT-12 generator (Tomsk, Russia) at currents of 2 MA. The plasma shell consisting of hydrogen and carbon ions was formed by 48 plasma guns. The deuterium gas-puff was created by a fast electromagnetic valve. This configuration provides an efficient mode of the neutron production in DD reaction, and the neutron yield reaches a value above 1012 neutrons per shot. Neutron diagnostics included scintillation TOF detectors for determination of the neutron energy spectrum, bubble detectors BD-PND, a silver activation detector, and several activation samples for determination of the neutron yield analysed by a Sodium Iodide (NaI) and a high-purity Germanium (HPGe) detectors. Using this neutron diagnostic complex, we measured the total neutron yield and amount of high-energy neutrons