131 research outputs found

    Stopping power of Au for silver ions at low velocities

    Get PDF
    Energy loss measurements for the slowing down of Ag ions in Au, in the velocity range 1:6v0 < v < 4:4v0, where v0 is the Bohr velocity, are presented. The measurements were performed using the Doppler shift technique and also with a new method, where a secondary beam of low velocity heavy ions is produced by elastic scattering of the accelerated beam. The results are compared to the SRIM2000 calculations (www.srim.org) and to recent measurements in this velocity region

    Computational modeling of ovarian cancer dynamics suggests optimal strategies for therapy and screening

    Get PDF
    High-grade serous tubo-ovarian carcinoma (HGSC) is a major cause of cancer-related death. Treatment is not uniform, with some patients undergoing primary debulking surgery followed by chemotherapy (PDS) and others being treated directly with chemotherapy and only having surgery after three to four cycles (NACT). Which strategy is optimal remains controversial. We developed a mathematical framework that simulates hierarchical or stochastic models of tumor initiation and reproduces the clinical course of HGSC. After estimating parameter values, we infer that most patients harbor chemoresistant HGSC cells at diagnosis and that, if the tumor burden is not too large and complete debulking can be achieved, PDS is superior to NACT due to better depletion of resistant cells. We further predict that earlier diagnosis of primary HGSC, followed by complete debulking, could improve survival, but its benefit in relapsed patients is likely to be limited. These predictions are supported by primary clinical data from multiple cohorts. Our results have clear implications for these key issues in HGSC management

    PACS: 29.30.-h; 29.30.Ep; 29.30.Kv

    Get PDF
    Abstract A large solid angle low-Z charged particle detector system was built in order to improve the quality of the identification and selection of evaporation channels for in-beam g-spectroscopy measurements. The array consists of 11 plastic phoswich telescopes closely packed in a 4p arrangement and to be used as an ancillary system for the Pelletron Laboratory g-ray spectrometer. The new system was tested in g-particle and g-g-particle coincidence measurements using the 27 Al þ 16 O and 100 Mo þ 11 B reactions, at 53 and 43 MeV incident beam energies, respectively. The values for the particle detection efficiency and improvement in the peak to background ratios are considered acceptable for the usefulness of the system.

    Towards successful coordination of electronic health record based-referrals: a qualitative analysis

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Successful subspecialty referrals require considerable coordination and interactive communication among the primary care provider (PCP), the subspecialist, and the patient, which may be challenging in the outpatient setting. Even when referrals are facilitated by electronic health records (EHRs) (<it>i.e</it>., e-referrals), lapses in patient follow-up might occur. Although compelling reasons exist why referral coordination <it>should </it>be improved, little is known about which elements of the complex referral coordination process should be targeted for improvement. Using Okhuysen & Bechky's coordination framework, this paper aims to understand the barriers, facilitators, and suggestions for improving communication and coordination of EHR-based referrals in an integrated healthcare system.</p> <p>Methods</p> <p>We conducted a qualitative study to understand coordination breakdowns related to e-referrals in an integrated healthcare system and examined work-system factors that affect the timely receipt of subspecialty care. We conducted interviews with seven subject matter experts and six focus groups with a total of 30 PCPs and subspecialists at two tertiary care Department of Veterans Affairs (VA) medical centers. Using techniques from grounded theory and content analysis, we identified organizational themes that affected the referral process.</p> <p>Results</p> <p>Four themes emerged: lack of an institutional referral policy, lack of standardization in certain referral procedures, ambiguity in roles and responsibilities, and inadequate resources to adapt and respond to referral requests effectively. Marked differences in PCPs' and subspecialists' communication styles and individual mental models of the referral processes likely precluded the development of a <it>shared </it>mental model to facilitate coordination and successful referral completion. Notably, very few barriers related to the EHR were reported.</p> <p>Conclusions</p> <p>Despite facilitating information transfer between PCPs and subspecialists, e-referrals remain prone to coordination breakdowns. Clear referral policies, well-defined roles and responsibilities for key personnel, standardized procedures and communication protocols, and adequate human resources must be in place before implementing an EHR to facilitate referrals.</p

    γ-Particle coincidence technique for the study of nuclear reactions

    Get PDF
    a b s t r a c t The Saci-Perere γ ray spectrometer (located at the Pelletron AcceleratorLaboratory -IFUSP) was employed to implement the γ-particle coincidence technique for the study of nuclear reaction mechanisms. For this, the Pd has been extracted and compared to coupled channel calculations using the São Paulo Potential (PSP), being reasonably well described by it

    The Lipid Paradox is present in ST-elevation but not in non-ST-elevation myocardial infarction patients:Insights from the Singapore Myocardial Infarction Registry

    Get PDF
    Lowering low-density lipoprotein (LDL-C) and triglyceride (TG) levels form the cornerstone approach of cardiovascular risk reduction, and a higher high-density lipoprotein (HDL-C) is thought to be protective. However, in acute myocardial infarction (AMI) patients, higher admission LDL-C and TG levels have been shown to be associated with better clinical outcomes - termed the 'lipid paradox'. We studied the relationship between lipid profile obtained within 72 hours of presentation, and all-cause mortality (during hospitalization, at 30-days and 12-months), and rehospitalization for heart failure and non-fatal AMI at 12-months in ST-segment elevation myocardial infarction (STEMI) and non-ST-segment elevation myocardial infarction (NSTEMI) patients treated by percutaneous coronary intervention (PCI). We included 11543 STEMI and 8470 NSTEMI patients who underwent PCI in the Singapore Myocardial Infarction Registry between 2008-2015. NSTEMI patients were older (60.3 years vs 57.7 years, p < 0.001) and more likely to be female (22.4% vs 15.0%, p < 0.001). In NSTEMI, a lower LDL-C was paradoxically associated with worse outcomes for death during hospitalization, within 30-days and within 12-months (all p < 0.001), but adjustment eliminated this paradox. In contrast, the paradox for LDL-C persisted for all primary outcomes after adjustment in STEMI. For NSTEMI patients, a lower HDL-C was associated with a higher risk of death during hospitalization but in STEMI patients a lower HDL-C was paradoxically associated with a lower risk of death during hospitalization. For this endpoint, the interaction term for HDL-C and type of MI was significant even after adjustment. An elevated TG level was not protective after adjustment. These observations may be due to differing characteristics and underlying pathophysiological mechanisms in NSTEMI and STEMI
    corecore